The Diagnostic Value of Compression Ultrasonography in Patients with Suspected Recurrent Deep Vein Thrombosis
The DOI matches its Crossref record.
Abstract
Summary: Diagnosis of recurrent deep-vein thrombosis (DVT) is difficult because of limitations in distinguishing acute from old thrombi. In the past, an ultrasound method for diagnosis of recurrent ipsilateral DVT was developed, which relies on repeated measurements of the diameters of the common femoral and popliteal veins. To assess the safety of withholding anticoagulation from patients with improved or stable compression vein diameters, 205 consecutive patients presenting with suspected recurrent ipsilateral DVT were evaluated. The vein diameter was measured under compression with the transducer and compared with earlier ultrasound results. Patients with stable or improved ultrasound findings had repeat ultrasound assessments after 2 (± 1) and 7 (± 1) days. Patients with repeatedly normal ultrasound results were followed-up for six months to determine the incidence of symptomatic recurrent venous thromboembolism. Of the 205 patients, 153 had stable or improved ultrasound findings. Repeat ultrasound assessment became abnormal in 3, and recurrence was confirmed by venography in all. A six months follow-up was done in the remaining 150 patients with repeatedly normal ultrasound tests and showed 2 (1.3%; 95% CI, 0.02 to 4.7%) confirmed non-fatal venous thromboembolic complications. The positive predictive value of a stable or improved ultrasound was 90% (95% CI, 77 to 97%). In conclusion, it is safe to withhold anticoagulant treatment from patients with suspected recurrent ipsilateral DVT in whom compression ultrasonography showed improved or stable vein diameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2003) · New England Journal of Medicine · doi:10.1056/nejmoa035451 · Cited by 887
Prandoni, P., Noventa, F., Ghirarduzzi, A., Pengo, V., Bernardi, E., Pesavento, R., Iotti, M., Tormene, D., Simioni, P., & Pagnan, A. (2007) · Haematologica · doi:10.3324/haematol.10516 · Cited by 776
Self-citationBates, S. M., Jaeschke, R., Stevens, S. M., Goodacre, S., Wells, P. S., Stevenson, M. D., Kearon, C., Schunemann, H. J., Crowther, M., Pauker, S. G., et al. (2012) · Chest · doi:10.1378/chest.11-2299 · Cited by 686
Prandoni, P., Lensing, A. W. A., Prins, M. H., Frulla, M., Marchiori, A., Bernardi, E., Tormene, D., Mosena, L., Pagnan, A., & Girolami, A. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-4-200408170-00004 · Cited by 659
Self-citationAspirin for Preventing the Recurrence of Venous Thromboembolism
Becattini, C., Agnelli, G., Schenone, A., Eichinger, S., Bucherini, E., Silingardi, M., Bianchi, M., Moia, M., Ageno, W., Vandelli, M. R., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114238 · Cited by 620
Self-citation
Metadata
- Authors
- Lensing, A., Bernardi, E., Villalta, S., Bagatella, P., Girolami, A., Prandoni, P., & for the DERECUS Investigators Group
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2002
- Volume
- 88
- Issue
- 09
- Pages
- 402-406
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W1843725133
- Cited by
- 119
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Diagnostic Value of Compression Ultrasonography in Patients with Suspected Recurrent Deep Vein Thrombosis. https://app.cochat.ai/papers/10.1055/s-0037-1613229
- The paper
- Lensing, A., Bernardi, E., Villalta, S., Bagatella, P., Girolami, A., Prandoni, P., & for the DERECUS Investigators Group. (2002). The Diagnostic Value of Compression Ultrasonography in Patients with Suspected Recurrent Deep Vein Thrombosis. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1613229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.