Anti Xa Monitoring during Treatment with Low Molecular Weight Heparin or Danaparoid: Inter-assay Variability
The DOI matches its Crossref record.
Abstract
Summary: If laboratory monitoring of low molecular weight heparin (LMWH) therapy is required the test of choice is the anti Xa activity assay. The relationship between anti Xa results obtained using different techniques is unknown. The aim of the present study was to compare anti Xa results obtained with eight different commercially available anti Xa activity assays (five chromogenic and three clotting based assays) in samples from patients receiving either therapeutic or prophylactic LMWH (enoxaparin or dalteparin) or danaparoid. We have demonstrated that highly significant differences exist between results obtained using different techniques. The mean anti Xa activity in patients receiving treatment or prophylaxis with enoxaparin ranged from 0.28 to 0.64 iu/ml. A similar relationship was present in samples from patients treated with dalteparin, mean anti Xa results ranging from 0.43 to 0.69 iu/ml. The Heptest clotting assay as used here in combination with the Automated Coagulation Laboratory instrument, was associated with lower results than other clotting or chromogenic techniques. In patients receiving danaparoid for heparin induced thrombocytopaenia (HIT) mean results with three clotting based assays were 0.30 to 0.36 u/ml, compared to mean results of 0.47 to 0.65 u/ml for chromogenic assays. Our data clearly indicate that the selection of anti Xa assay method could influence patient management since the dose required to achieve the therapeutic range would differ according to the assay employed. This is particularly important since the frequency of hamorrhagic side effects has been shown by others to be dose dependant, irrespective of the concomitant anti Xa activity results. In danaparoid therapy the clotting assays studied here should not be employed for monitoring without a modified target range, unless it can be demonstrated that the higher doses required to achieve the therapeutic range are safe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
VTE, Thrombophilia, Antithrombotic Therapy, and Pregnancy
Bates, S. M., Greer, I. A., Middeldorp, S., Veenstra, D. L., Prabulos, A.-M., & Vandvik, P. O. (2012) · Chest · doi:10.1378/chest.11-2300 · Cited by 1,525
Garcia, D. A., Baglin, T. P., Weitz, J. I., & Samama, M. M. (2012) · Chest · doi:10.1378/chest.11-2291 · Cited by 1,091
Venous Thromboembolism, Thrombophilia, Antithrombotic Therapy, and Pregnancy
Bates, S. M., Greer, I. A., Pabinger, I., Sofaer, S., & Hirsh, J. (2008) · Chest · doi:10.1378/chest.08-0761 · Cited by 793
Hirsh, J., Bauer, K. A., Donati, M. B., Gould, M., Samama, M. M., & Weitz, J. I. (2008) · Chest · doi:10.1378/chest.08-0689 · Cited by 755
Bates, S. M., Rajasekhar, A., Middeldorp, S., McLintock, C., Rodger, M. A., James, A. H., Vazquez, S. R., Greer, I. A., Riva, J. J., Bhatt, M., et al. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018024802 · Cited by 625
Metadata
- Authors
- Iampietro, R., Woolley, A. M., Preston, F. E., & Kitchen, S.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1999
- Volume
- 82
- Issue
- 10
- Pages
- 1289-1293
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2113031661
- Cited by
- 112
- References
- 0
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anti Xa Monitoring during Treatment with Low Molecular Weight Heparin or Danaparoid: Inter-assay Variability. https://app.cochat.ai/papers/10.1055/s-0037-1614377
- The paper
- Iampietro, R., Woolley, A. M., Preston, F. E., & Kitchen, S. (1999). Anti Xa Monitoring during Treatment with Low Molecular Weight Heparin or Danaparoid: Inter-assay Variability. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1614377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.