Comparative Diagnostic Performance of Three Radiological Procedures for the Detection of Lumbar Disk Herniation
The DOI matches its Crossref record.
Abstract
Literature data on the diagnostic performance of phlebography, myelography, and CT scan applied to patients with suspected lumbar disk herniation (LDH) are analyzed to extract maximal information about their relative discriminatory power. Seventeen papers meeting the selection criteria contain 13 reports on myelography, 6 on phlebography, and 5 on CT. Sensitivity and specificity are considered simultaneously in logistic ROC space. The reports of each procedure are effectively summarized by a linear regression in logistic ROC space. Taking into account the individual confidence regions of sensitivity and specificity obtained from each report, the slope of the regression line is estimated by Generalized Least Squares (ML). This approach also allows to test the assumption of a common odds ratio (i.e., of a unit slope). The simply to determine common odds ratio as well as the perpendicular distance between the origin and the regression line (as a good approximation to the area under the ROC curve) are used as a measure for the discriminatory power of the procedures. For CT, homogeneity of sensitivity turns out to be much more likely than a common odds ratio. Based on the available, retrospective data, phlebography appears to have the highest performance in visualizing an LDH, followed by myelography and CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
“The bivariate model is based on the following line o reasoning[10,24,25] .”
MethodThe diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
“The approach by Littenberg and Moses relies on the linear regression of the logarithm of the DOR of a study (dependent variable) on a expression of the positivity threshold of that study (independent variable).”
MethodA hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Meta-analysis of screening and diagnostic tests.
Hasselblad, V., & Hedges, L. V. (1995) · Psychological Bulletin · doi:10.1037/0033-2909.117.1.167 · Cited by 579
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Does This Patient Have Strep Throat?
Ebell, M. H. (2000) · JAMA · doi:10.1001/jama.284.22.2912 · Cited by 327
Bivariate Random Effects Meta-Analysis of ROC Curves
Arends, L. R., Hamza, T. H., van Houwelingen, J. C., Heijenbrok-Kal, M. H., Hunink, M. G. M., & Stijnen, T. (2008) · Medical Decision Making · doi:10.1177/0272989x08319957 · Cited by 325
Radiological Evaluation of Lymph Node Metastases in Patients With Cervical Cancer: A Meta-analysis
Scheidler, J. (1997) · JAMA · doi:10.1001/jama.1997.03550130070040 · Cited by 320
Cochrane diagnostic test accuracy reviews
Leeflang, M. M., Deeks, J. J., Takwoingi, Y., & Macaskill, P. (2013) · Systematic Reviews · doi:10.1186/2046-4053-2-82 · Cited by 292
Champaneria, R., Abedin, P., Daniels, J., Balogun, M., & Khan, K. S. (2010) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.3109/00016349.2010.512061 · Cited by 241
Sun, W., Cui, H., Li, N., Wei, Y., Lai, S., Yang, Y., Yin, X., & Chen, D. (2016) · Hepatology Research · doi:10.1111/hepr.12647 · Cited by 236
Meta-Analysis of Diagnostic and Screening Test Accuracy Evaluations: Methodologic Primer
Gatsonis, C., & Paliwal, P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.06.0226 · Cited by 215
“An early such approach predated the linear regression method and used the bivariate normal distribution of the estimates of sensitivity and specificity from each study, with a linear relation between the true values of sensitivity and specificity to account for the effect of threshold [25].”
MethodDiagnosis of vascular catheter-related bloodstream infection: a meta-analysis
Siegman-Igra, Y., Anglim, A. M., Shapiro, D. E., Adal, K. A., Strain, B. A., & Farr, B. M. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.4.928-936.1997 · Cited by 211
“The Breslow-Day test (10) of homogeneity of odds ratios was used to test the hypothesis that B 5 0, and the Kardaun-Kardaun test (44) was used to assess the adequacy of the summary ROC curve.”
MethodMacaskill, P. (2004) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2003.12.019 · Cited by 210
“An SROC model was proposed initially by Kardaun and Kardaun (1990) [8].”
MethodThe Area under the ROC Curve and Its Competitors
Hilden, J. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100204 · Cited by 185
Estimating the accuracy of screening mammography
Mushlin, A. I., Kouides, R. W., & Shapiro, D. E. (1998) · American Journal of Preventive Medicine · doi:10.1016/s0749-3797(97)00019-6 · Cited by 176
Janne d’Othée, B., Siebert, U., Cury, R., Jadvar, H., Dunn, E. J., & Hoffmann, U. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.05.003 · Cited by 161
“Presence and magnitude of heterogeneity were assessed based on the inspection of forest and ROC plots [27,28], on hypothesis testing [29], and on the use of the I2 statistic [19].”
MethodMeta-analysis and structured literature review in radiology1
Doria, A. S. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.01.007 · Cited by 9
Metadata
- Authors
- Kardaun, J. W. P. F., & Kardaun, O. J. W. F.
- Venue
- Methods of Information in Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1990
- Volume
- 29
- Issue
- 01
- Pages
- 12-22
- ISSN
- 0026-1270 (ISSN-L)
- 2511-705X
- OpenAlex
- W2416389823
- Cited by
- 74
- References
- 0
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.