The DOI matches its Crossref record.
Laboratory Diagnosis of APC-Resistance: A Critical Evaluation of the Test and the Development of Diagnostic Criteria
Abstract
Summary: The APC-resistance test consists of two APTT’s, one in the presence and one in the absence of a fixed amount of Activated Protein C (APC), and is a simple and reliable method to detect a reduced sensitivity to the anticoagulant action of APC (APC-resistance). At a fixed concentration of APC the prolongation of the APTT is dependent on the activator, the CaCl2 concentration, the citrate concentration in the sample, and on sample handling. The effect of sample handling can be reduced by calculating the APC-Sensitivity Ratio (APC-SR). The actual prolongation of the APTT is also influenced by low protein S levels (reduction of APC-SR) and by reduced levels of factors V, VIII and IX (increase of APC-SR). The APC-SR is most dramaticly effected by reduced levels of factors II and X, which result often in “unmeasurable” APC-SR’s in plasmas of patients on oral anticoagulant treatment. So at present no reliable APC-SR’s can be measured in these patients. Patients treated with heparin can be tested after treatment of their plasma with Hepzym®. The inter- and intra-assay variation in the APC-SR is 4% and 2%, respectively, when using the same batches of activator and APC. The variation which is introduced in the APC-SR by use of different batches of activator or APC, or by the use of different APC or CaCl2 concentrations, can effectively be avoided by expressing the result of the test in normalized-APC-SR (n-APC-SR). The diagnosis of APC-resistance is defined by a n-APC-SR < 0.84. Patients who are heterozygous for the Factor V Leiden mutation have a n-APC-SR of 0.45-0.70, while patients who are homozygous for the mutation have a n-APC-SR <0.45.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Martinelli, I., Sacchi, E., Landi, G., Taioli, E., Duca, F., & Mannucci, P. M. (1998) · New England Journal of Medicine · doi:10.1056/nejm199806183382502 · Cited by 648
Activated Protein C Sensitivity, Protein C, Protein S and Coagulation in Normal Pregnancy
Brennand, J., Conkie, J. A., McCall, F., Greer, I. A., Walker, I., & Clark, P. (1998) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1615035 · Cited by 386
Rosing, J., Tans, G., Nicolaes, G. A. F., Thomassen, M. C. L. G. D., Van Oerle, R., Van DerPloeg, P. M. E. N., Heijnen, P., Hamulyak, K., & Hemker, H. C. (1997) · British Journal of Haematology · doi:10.1046/j.1365-2141.1997.192707.x · Cited by 325
de Visser, M. C. H., Rosendaal, F. R., & Bertina, R. M. (1999) · Blood · doi:10.1182/blood.v93.4.1271 · Cited by 308
Self-citationInvestigation and management of heritable thrombophilia
Walker, I. D., Greaves, M., & Preston, F. E. (2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.02981.x · Cited by 299
Metadata
- Authors
- de Ronde, H., & Bertina, R. M.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1994
- Volume
- 72
- Issue
- 06
- Pages
- 880-886
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W458440
- Cited by
- 186
- References
- 0
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory Diagnosis of APC-Resistance: A Critical Evaluation of the Test and the Development of Diagnostic Criteria. https://app.cochat.ai/papers/10.1055/s-0038-1648978
- The paper
- de Ronde, H., & Bertina, R. M. (1994). Laboratory Diagnosis of APC-Resistance: A Critical Evaluation of the Test and the Development of Diagnostic Criteria. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1648978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.