The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Nijmegen Modification of the Bethesda Assay for Factor VIII:C Inhibitors: Improved Specificity and Reliability
Open accessAbstract
Summary: Antibodies against factor VIII coagulant activity can appear in haemophiliacs who are treated with factor VIII preparations but also spontaneously in non-haemophiliacs. The Bethesda assay is the most commonly used method to detect these antibodies, but it lacks specificity especially in the lower range resulting in unreliable data. Two modifications are proposed and tested to resolve the imperfections: 1. Buffering the normal plasma used in the assay- and control mixture with 0.1 M imidazole to pH 7.4. Replacing the imidazole buffer in the control mixture by immunodepleted factor VIII deficient plasma. These modifications allow better discrimination between positive and negative samples and improve reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lusher, J. M., Arkin, S., Abildgaard, C. F., & Schwartz, R. S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302183280701 · Cited by 476
Cited by
International Recommendations on the Diagnosis and Treatment of Acquired Hemophilia A
Tiede, A., Collins, P., Knoebl, P., Teitel, J., Kessler, C., Shima, M., Di Minno, G., d’Oiron, R., Salaj, P., Jiménez-Yuste, V., et al. (2020) · Haematologica · doi:10.3324/haematol.2019.230771 · Cited by 401
VALENTINO, L. A., MAMONOV, V., HELLMANN, A., QUON, D. V., CHYBICKA, A., SCHROTH, P., PATRONE, L., & WONG, W. ‐. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04611.x · Cited by 253
Laboratory Diagnosis of Acquired Hemophilia A: Limitations, Consequences, and Challenges
Werwitzke, S., Scharf, R., & Tiede, A. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0034-1390004 · Cited by 114
Tripodi, A., Mancuso, M. E., Chantarangkul, V., Clerici, M., Bader, R., Meroni, P. L., Santagostino, E., & Mannucci, P. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.054312 · Cited by 44
Shetty, S., Ghosh, K., & Mohanty, D. (2003) · Acta Haematologica · doi:10.1159/000067272 · Cited by 30
Metadata
- Authors
- Verbruggen, B., Novakova, I., Wessels, H., Boezeman, J., van den Berg, M., & Mauser-Bunschoten, E.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1995
- Volume
- 73
- Issue
- 02
- Pages
- 247-251
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2149564822
- Cited by
- 652
- References
- 1
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Nijmegen Modification of the Bethesda Assay for Factor VIII:C Inhibitors: Improved Specificity and Reliability. https://app.cochat.ai/papers/10.1055/s-0038-1653759
- The paper
- Verbruggen, B., Novakova, I., Wessels, H., Boezeman, J., van den Berg, M., & Mauser-Bunschoten, E. (1995). The Nijmegen Modification of the Bethesda Assay for Factor VIII:C Inhibitors: Improved Specificity and Reliability. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1653759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.