The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Mass Action Effects on Competitive Adsorption of Fibrinogen from Hemoglobin Solutions and from Plasma
Abstract
Summary: The strong effect of protein adsorption on blood and tissue compatibility is well known. Little is presently known about the mechanisms which control the composition of the adsorbed protein layer which forms upon exposure of surfaces to mixtures of proteins. Reexamination of the ability of hemoglobin to inhibit the adsorption of 125I fibrinogen to polyethylene revealed that the inhibition was strongly dependent on the fibrinogen concentration. These results suggested that fibrinogen adsorption from more complex mixtures such as plasma should also be strongly dependent on total concentration. Fibrinogen adsorption from plasma was found to be maximal at intermediate plasma concentrations, and was reduced at both low and high plasma concentrations. The plasma concentration at which this maximum occurred was 10% for polytetrafluoroethylene, 1% for polyethylene, and 0.1% for glass. The unusual concentration dependence is attributed to mass action effects on the competitive adsorption of proteins, specifically that competitive effectiveness is expected to increase as unoccupied surface adsorptive sites become less frequent. Analogous effects of adsorption time on competitive adsorption are also predicted due to the changing concentration at the interface as the buffer is gradually replaced by protein solution. These mass action effects are very similar to previous qualitative observations by Vroman and are therefore dubbed the “Vroman effect”.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of cell shape in growth control
Folkman, J., & Moscona, A. (1978) · Nature · doi:10.1038/273345a0 · Cited by 2,422
Influence of Substratum Characteristics on the Attachment of a Marine Pseudomonad to Solid Surfaces
Fletcher, M., & Loeb, G. I. (1979) · Applied and Environmental Microbiology · doi:10.1128/aem.37.1.67-72.1979 · Cited by 587
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181
Cited by
The Vroman effect: Competitive protein exchange with dynamic multilayer protein aggregates
Hirsh, S. L., McKenzie, D. R., Nosworthy, N. J., Denman, J. A., Sezerman, O. U., & Bilek, M. M. M. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2012.10.039 · Cited by 340
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
Tsai, W.-B., Grunkemeier, J. M., & Horbett, T. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<130::aid-jbm2>3.0.co;2-9 · Cited by 329
Self-citationThe blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Self-citation
Metadata
- Authors
- Horbett, T. A.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1984
- Volume
- 51
- Issue
- 02
- Pages
- 174-181
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2475067738
- Cited by
- 158
- References
- 3
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass Action Effects on Competitive Adsorption of Fibrinogen from Hemoglobin Solutions and from Plasma. https://app.cochat.ai/papers/10.1055/s-0038-1661052
- The paper
- Horbett, T. A. (1984). Mass Action Effects on Competitive Adsorption of Fibrinogen from Hemoglobin Solutions and from Plasma. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1661052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.