Objective Rule-based data quality assessment in health care facilities was explored through compilation, implementation, and evaluation of 63,397 data quality rules in a single-center case study to assess the ability of rules-based data quality assessment to identify data errors of importance to physicians and system owners. Methods We applied a design science framework to design, demonstrate, test, and evaluate a scalable framework with which data quality rules can be managed and used in health care facilities for data quality assessment and monitoring. Results We identified 63,397 rules partitioned into 28 logic templates. A total of 819,683 discrepancies were identified by 4.5% of the rules. Nine out of 11 participating clinical and operational leaders indicated that the rules identified data quality problems and articulated next steps that they wanted to take based on the reported information. Discussion The combined rule template and knowledge table approach makes governance and maintenance of otherwise large rule sets manageable. Identified challenges to rule-based data quality monitoring included the lack of curated and maintained knowledge sources relevant to data error detection and lack of organizational resources to support clinical and operational leaders with investigation and characterization of data errors and pursuit of corrective and preventative actions. Limitations of our study included implementation within a single center and dependence of the results on the implemented rule set. Conclusion This study demonstrates a scalable framework (up to 63,397 rules) with which data quality rules can be implemented and managed in health care facilities to identify data errors. The data quality problems identified at the implementation site were important enough to prompt action requests from clinical and operational leaders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0040-1715567

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 45

Metadata

Authors
Wang, Z., Talburt, J. R., Wu, N., Dagtas, S., & Zozus, M. N.
Venue
Applied Clinical Informatics
Published
2020-08
Volume
11
Issue
04
Pages
622-634
ISSN
1869-0327 (ISSN-L)
OpenAlex
W3087781820
Cited by
45
References
4
FWCI
5.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Rule-Based Data Quality Assessment System for Electronic Health Record Data. https://app.cochat.ai/papers/10.1055/s-0040-1715567
The paper
Wang, Z., Talburt, J. R., Wu, N., Dagtas, S., & Zozus, M. N. (2020). A Rule-Based Data Quality Assessment System for Electronic Health Record Data. Applied Clinical Informatics. https://doi.org/10.1055/s-0040-1715567

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.