Abstract

BACKGROUND AND STUDY AIMS: In order to reduce time, costs, and risks associated with resection of diminutive colorectal polyps, the American Society for Gastrointestinal Endoscopy (ASGE) recently proposed performance thresholds that new technologies should meet for the accurate real-time assessment of histology of colorectal polyps. In this study, we prospectively assessed whether laser-induced fluorescence spectroscopy (LIFS), using the new WavSTAT4 optical biopsy system, can meet the ASGE criteria. PATIENTS AND METHODS: 27 patients undergoing screening or surveillance colonoscopy were included. The histology of 137 diminutive colorectal polyps was predicted in real time using LIFS and findings were compared with the results of conventional histopathological examination. The accuracy of predicting polyp histology with WavSTAT4 was assessed according to the ASGE criteria. RESULTS: The overall accuracy of LIFS using WavSTAT4 for predicting polyp histology was 84.7 % with sensitivity, specificity, and negative predictive value (NPV) of 81.8 %, 85.2 %, and 96.1 %. When only distal colorectal diminutive polyps were considered, the NPV for excluding adenomatous histology increased to 100 % (accuracy 82.4 %, sensitivity 100 %, specificity 80.6 %). On-site, LIFS correctly predicted the recommended surveillance intervals with an accuracy of 88.9 % (24/27 patients) when compared with histology-based United States guideline recommendations; in the 3 patients for whom LIFS- and histopathology-based recommended surveillance intervals differed, LIFS predicted shorter surveillance intervals. CONCLUSIONS: From the data of this pilot study, LIFS using the WavSTAT4 system appears accurate enough to allow distal colorectal polyps to be left in place and nearly reaches the threshold to "resect and discard" them without pathologic assessment. WavSTAT4 therefore has the potential to reduce costs and risks associated with the removal of diminutive colorectal polyps.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0042-102251

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 73

Metadata

Authors
Rath, T., Tontini, G., Vieth, M., Nägel, A., Neurath, M., & Neumann, H.
Venue
Endoscopy
Published
2016-03-23
Volume
48
Issue
06
Pages
557-562
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2303541029
Cited by
73
References
0
FWCI
2.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo real-time assessment of colorectal polyp histology using an optical biopsy forceps system based on laser-induced fluorescence spectroscopy. https://app.cochat.ai/papers/10.1055/s-0042-102251
The paper
Rath, T., Tontini, G., Vieth, M., Nägel, A., Neurath, M., & Neumann, H. (2016). In vivo real-time assessment of colorectal polyp histology using an optical biopsy forceps system based on laser-induced fluorescence spectroscopy. Endoscopy. https://doi.org/10.1055/s-0042-102251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.