Modified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration
Abstract
Purpose Lung Ultrasound Score (LUSS) is a useful tool for lung aeration assessment but presents two theoretical limitations. First, standard LUSS is based on longitudinal scan and detection of number/coalescence of B lines. In the longitudinal scan pleura visualization is limited by intercostal space width. Moreover, coalescence of B lines to define severe loss of aeration is not suitable for non-homogeneous lung pathologies where focal coalescence is possible. We therefore compared longitudinal vs. transversal scan and also cLUSS (standard coalescence-based LUSS) vs. qLUSS (quantitative LUSS based on % of involved pleura). Materials and methods 38 ICU patients were examined in 12 thoracic areas in longitudinal and transversal scan. B lines (number, coalescence), subpleural consolidations (SP), pleural length and pleural involvement (> or ≤ 50 %) were assessed. cLUSS and qLUSS were computed in longitudinal and transversal scan. Results Transversal scan visualized wider (3.9 [IQR 3.8 – 3.9] vs 2.0 [1.6 – 2.5] cm, p < 0.0001) and more constant (variance 0.02 vs 0.34 cm, p < 0.0001) pleural length, more B lines (70 vs 59 % of scans, p < 0.0001), coalescence (39 vs 28 %, p < 0.0001) and SP (22 vs 14 %, p < 0.0001) compared to longitudinal scan. Pleural involvement > 50 % was observed in 17 % and coalescence in 33 % of cases. Focal coalescence accounted for 52 % of cases of coalescence. qLUSS-transv generated a different distribution of aeration scores compared to cLUSS-long (p < 0.0001). Conclusion In unselected ICU patients, variability of pleural length in longitudinal scans is high and focal coalescence is frequent. Transversal scan and quantification of pleural involvement are simple measures to overcome these limitations of LUSS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Lung Ultrasound for Critically Ill Patients
Mojoli, F., Bouhemad, B., Mongodi, S., & Lichtenstein, D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0236ci · Cited by 513
Self-citationChiumello, D., Mongodi, S., Algieri, I., Vergani, G. L., Orlando, A., Via, G., Crimella, F., Cressoni, M., & Mojoli, F. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003340 · Cited by 308
Self-citation
Metadata
- Authors
- Mongodi, S., Bouhemad, B., Orlando, A., Stella, A., Tavazzi, G., Via, G., Iotti, G., Braschi, A., & Mojoli, F.
- Venue
- Ultraschall in der Medizin - European Journal of Ultrasound
- Publisher
- Georg Thieme Verlag KG
- Published
- 2017-03-14
- Volume
- 38
- Issue
- 05
- Pages
- 530-537
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W2602949542
- Cited by
- 178
- References
- 0
- FWCI
- 8.42
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration. https://app.cochat.ai/papers/10.1055/s-0042-120260
- The paper
- Mongodi, S., Bouhemad, B., Orlando, A., Stella, A., Tavazzi, G., Via, G., Iotti, G., Braschi, A., & Mojoli, F. (2017). Modified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/s-0042-120260
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.