Accuracy of diagnosing invasive colorectal cancer using computer-aided endocytoscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background and study aims Invasive cancer carries the risk of metastasis, and therefore, the ability to distinguish between invasive cancerous lesions and less-aggressive lesions is important. We evaluated a computer-aided diagnosis system that uses ultra-high (approximately × 400) magnification endocytoscopy (EC-CAD). Patients and methods We generated an image database from a consecutive series of 5843 endocytoscopy images of 375 lesions. For construction of a diagnostic algorithm, 5543 endocytoscopy images from 238 lesions were randomly extracted from the database for machine learning. We applied the obtained algorithm to 200 endocytoscopy images and calculated test characteristics for the diagnosis of invasive cancer. We defined a high-confidence diagnosis as having a ≥ 90 % probability of being correct. Results Of the 200 test images, 188 (94.0 %) were assessable with the EC-CAD system. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were 89.4 %, 98.9 %, 94.1 %, 98.8 %, and 90.1 %, respectively. High-confidence diagnosis had a sensitivity, specificity, accuracy, PPV, and NPV of 98.1 %, 100 %, 99.3 %, 100 %, and 98.8 %, respectively. Conclusion: EC-CAD may be a useful tool in diagnosing invasive colorectal cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rex, D. K., Kahi, C., O'Brien, M., Levin, T. R., Pohl, H., Rastogi, A., Burgart, L., Imperiale, T., Ladabaum, U., Cohen, J., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.01.023 · Cited by 629 · cited 1×
“Before initiation of the present study, we defined high-confidence diagnosis as having a ≥ 90% probability of being correct, as described previously [13].”
MethodPatel, S. G., Schoenfeld, P., Kim, H. M., Ward, E. K., Bansal, A., Kim, Y., Hosford, L., Myers, A., Foster, S., Craft, J., et al. (2016) · Gastroenterology · doi:10.1053/j.gastro.2015.10.042 · Cited by 87 · cited 1×
“Although each method has a highly accurate diagnostic ability, results are operator dependent [7]; it is difficult for all endoscopists to be trained to provide excellent performance with all methods.”
Background
Cited by
Application of Artificial Intelligence to Gastroenterology and Hepatology
Le Berre, C., Sandborn, W. J., Aridhi, S., Devignes, M.-D., Fournier, L., Smaïl-Tabbone, M., Danese, S., & Peyrin-Biroulet, L. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.08.058 · Cited by 516
Chen, Z., Lin, L., Wu, C., Li, C., Xu, R., & Sun, Y. (2021) · Cancer Communications · doi:10.1002/cac2.12215 · Cited by 285
Artificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Application of artificial intelligence in gastroenterology
Yang, Y. J., & Bang, C. S. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i14.1666 · Cited by 263
Ogino, S., Nowak, J. A., Hamada, T., Milner, D. A., & Nishihara, R. (2019) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathmechdis-012418-012818 · Cited by 252
Artificial Intelligence-assisted System Improves Endoscopic Identification of Colorectal Neoplasms
Kudo, S.-E., Misawa, M., Mori, Y., Hotta, K., Ohtsuka, K., Ikematsu, H., Saito, Y., Takeda, K., Nakamura, H., Ichimasa, K., et al. (2020) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2019.09.009 · Cited by 242
Self-citationAhmad, O. F., Soares, A. S., Mazomenos, E., Brandao, P., Vega, R., Seward, E., Stoyanov, D., Chand, M., & Lovat, L. B. (2019) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(18)30282-6 · Cited by 215
Artificial intelligence and colonoscopy: Current status and future perspectives
Kudo, S., Mori, Y., Misawa, M., Takeda, K., Kudo, T., Itoh, H., Oda, M., & Mori, K. (2019) · Digestive Endoscopy · doi:10.1111/den.13340 · Cited by 147
Self-citationArtificial intelligence in gastrointestinal endoscopy: general overview
El Hajjar, A., & Rey, J.-F. (2020) · Chinese Medical Journal · doi:10.1097/cm9.0000000000000623 · Cited by 102
“More CADx were developed and studied to diagnose CRC such as the previously detailed CADx developed by Misawa et al[12] or the CADx developed by Takeda et al[59] to diagnose invasive CRC that showed an accuracy of 94.1%, a sensitivity of 89.4%, a specificity of 98.9%, a PPV 98.8%, and a NPV of 90.1%.”
MethodInfluentialChristou, C. D., & Tsoulfas, G. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i37.6191 · Cited by 54
Artificial intelligence and computer-aided diagnosis for colonoscopy: where do we stand now?
Kudo, S.-E., Mori, Y., Abdel-aal, U. M., Misawa, M., Itoh, H., Oda, M., & Mori, K. (2021) · Translational Gastroenterology and Hepatology · doi:10.21037/tgh.2019.12.14 · Cited by 21
“Various imaging technologies are considered as the targets for CAD for polyp characterization such as white-light endoscopy (12,13), magnifying narrow band imaging (NBI) (14,15), magnifying chromoendoscopy (16), endocytoscopy (17-20), confocal laser endomicroscopy (21) and laser-induced fluorescence spectroscopy (22-2…”
BackgroundSelf-citationvan Bokhorst, Q. N., Houwen, B. B., Hazewinkel, Y., Fockens, P., & Dekker, E. (2023) · Endoscopy International Open · doi:10.1055/a-2098-1999 · Cited by 8
“Deep learning approaches for differentiation of lesions with and without DSI have been proposed in several studies (▶Table 5) [101, 102, 103, 104, 105, 106, 107, 108].”
Use of Artificial Intelligence in the Diagnosis of Colorectal Cancer
Nduma, B. N., Nkeonye, S., Uwawah, T. D., Kaur, D., Ekhator, C., & Ambe, S. (2024) · Cureus · doi:10.7759/cureus.53024 · Cited by 6
“Computer-aided diagnosis (CAD) is another type of AI tool used to determine the effectiveness of AI technology in CRC diagnosis in one of the reviewed studies is CAD [14].”
Method
Metadata
- Authors
- Takeda, K., Kudo, S.-E., Mori, Y., Misawa, M., Kudo, T., Wakamura, K., Katagiri, A., Baba, T., Hidaka, E., Ishida, F., Inoue, H., Oda, M., & Mori, K.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2017-05-04
- Volume
- 49
- Issue
- 08
- Pages
- 798-802
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2610398104
- Cited by
- 140
- References
- 2
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.