Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Artificial intelligence may help in predicting the need for additional surgery after endoscopic resection of T1 colorectal cancer

Ichimasa, Katsuro, Kudo, Shin-ei, Mori, Yuichi, Misawa, Masashi, Matsudaira, Shingo, Kouyama, Yuta, Baba, Toshiyuki, Hidaka, Eiji, Wakamura, Kunihiko, Hayashi, Takemasa, Kudo, Toyoki, Ishigaki, Tomoyuki, Yagawa, Yusuke, Nakamura, Hiroki, Takeda, Kenichi, Haji, Amyn, Hamatani, Shigeharu, Mori, Kensaku, Ishida, Fumio, Miyachi, Hideyuki·2018·Endoscopy

Abstract

Background and study aims Decisions concerning additional surgery after endoscopic resection of T1 colorectal cancer (CRC) are difficult because preoperative prediction of lymph node metastasis (LNM) is problematic. We investigated whether artificial intelligence can predict LNM presence, thus minimizing the need for additional surgery. Patients and methods Data on 690 consecutive patients with T1 CRCs that were surgically resected in 2001 – 2016 were retrospectively analyzed. We divided patients into two groups according to date: data from 590 patients were used for machine learning for the artificial intelligence model, and the remaining 100 patients were included for model validation. The artificial intelligence model analyzed 45 clinicopathological factors and then predicted positivity or negativity for LNM. Operative specimens were used as the gold standard for the presence of LNM. The artificial intelligence model was validated by calculating the sensitivity, specificity, and accuracy for predicting LNM, and comparing these data with those of the American, European, and Japanese guidelines. Results Sensitivity was 100 % (95 % confidence interval [CI] 72 % to 100 %) in all models. Specificity of the artificial intelligence model and the American, European, and Japanese guidelines was 66 % (95 %CI 56 % to 76 %), 44 % (95 %CI 34 % to 55 %), 0 % (95 %CI 0 % to 3 %), and 0 % (95 %CI 0 % to 3 %), respectively; and accuracy was 69 % (95 %CI 59 % to 78 %), 49 % (95 %CI 39 % to 59 %), 9 % (95 %CI 4 % to 16 %), and 9 % (95 %CI 4 % – 16 %), respectively. The rates of unnecessary additional surgery attributable to misdiagnosing LNM-negative patients as having LNM were: 77 % (95 %CI 62 % to 89 %) for the artificial intelligence model, and 85 % (95 %CI 73 % to 93 %; P < 0.001), 91 % (95 %CI 84 % to 96 %; P < 0.001), and 91 % (95 %CI 84 % to 96 %; P < 0.001) for the American, European, and Japanese guidelines, respectively. Conclusions Compared with current guidelines, artificial intelligence significantly reduced unnecessary additional surgery after endoscopic resection of T1 CRC without missing LNM positivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0043-122385

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 158

Metadata

Authors
Ichimasa, K., Kudo, S.-E., Mori, Y., Misawa, M., Matsudaira, S., Kouyama, Y., Baba, T., Hidaka, E., Wakamura, K., Hayashi, T., Kudo, T., Ishigaki, T., Yagawa, Y., Nakamura, H., Takeda, K., Haji, A., Hamatani, S., Mori, K., Ishida, F., & Miyachi, H.
Venue
Endoscopy
Published
2017-12-22
Volume
50
Issue
03
Pages
230-240
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2776737272
Cited by
158
References
2
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial intelligence may help in predicting the need for additional surgery after endoscopic resection of T1 colorectal cancer. https://app.cochat.ai/papers/10.1055/s-0043-122385
The paper
Ichimasa, K., Kudo, S.-E., Mori, Y., Misawa, M., Matsudaira, S., Kouyama, Y., Baba, T., Hidaka, E., Wakamura, K., Hayashi, T., Kudo, T., Ishigaki, T., Yagawa, Y., Nakamura, H., Takeda, K., Haji, A., Hamatani, S., Mori, K., Ishida, F., & Miyachi, H. (2018). Artificial intelligence may help in predicting the need for additional surgery after endoscopic resection of T1 colorectal cancer. Endoscopy. https://doi.org/10.1055/s-0043-122385

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.