Automated Ultrasonic Measurement of Human Arteries for the Determination of Endothelial Function
The DOI matches its Crossref record.
Abstract
Aim: Brachial artery ultrasonography is used to measure flow-mediated dilatation (FMD) as a marker of endothelial function in patients at risk for atherosclerosis. Major disadvantages are the time-consuming manual readings and the high within- and between-observer variability. The authors hypothesize that the ultrasound-based determination of endothelial function can be simplified and refined by an automated analysis system. Methods and Results: FMD was quantified by a 7.5 MHz linear transducer following 5 minutes of ischemia of the proximal forearm in 8 healthy volunteers on two occasions. Brachial artery diameter was comparatively assessed 1. manually from the video signal and 2. by a PC-based analyzing system. For the manual readings the mean differences for the FMD were 2.5 ± 2.3 % between-reader, 2.0 ± 0.9 % within-reader and 2.1 ± 1.5 % for scans on different days in contrast to 0.8 ± 0.4 (between-reader), 0.8 ± 0.6 (within-reader) and 1.3 ± 0.9 % (day-to-day) for the computerized system. The coefficient of variability for the measurement of arterial diameter was 1.34 % for manual readings and 0.78 % for the automated analysis system. The mean time for manual readings from S-VHS tapes was 35 minutes in contrast to 9 minutes for the PC-based analysis system. Conclusions: The new automated analysis system for the boundary detection of the vascular wall reduces the variability and greatly increases the speed of the measurements to determine endothelial function. In future, these advantages will help to screen larger numbers of individuals for endothelial dysfunction, particularly for follow-up and intervention trials, and to reduce the variability between different laboratories. Automatisierte Analyse von Ultraschallbildern peripherer Arterien zur Bestimmung der Endothelfunktion Studienziel: Mittels Duplexsonographie erfolgt die Messung der flussabhängigen Dilatation der A. brachialis (FMD) als Marker der Endothelfunktion bei Patienten mit kardiovaskulären Risikofaktoren. Nachteilig sind der hohe zeitliche Aufwand sowie eine hohe Intra- und Inter-Observervariabilität. Ziel der Studie war es zu klären, ob die duplexsonographische FMD-Bestimmung durch ein PC-gestütztes Analysesystem vereinfacht und verbessert werden kann. Methoden und Resultate: Bei 8 Normalpersonen erfolgte die Bestimmung der FMD an zwei unterschiedlichen Tagen. Die Vermessung des Diameters der A. brachialis erfolgte 1. mittels manueller Auswertung des Videosignals und 2. mit Hilfe eines PC-gestützten Analysesystems. In der manuellen Auswertung betrug die mittlere Inter-Observer-Differenz 2,5 ± 2,3 %, die Intra-Observer-Differenz 2,0 ± 0,9 % und die Tag-zu-Tag-Differenz 2,1 ± 1,5 %. Im Gegensatz zu 0,8 ± 0,4 (Inter-Observer), 0,8 ± 0,6 (Intra-Observer) und 1,3 ± 0,9 % (Tag-zu-Tag) für die computergestützte Auswertung. Der Variationskoeffizient für die Bestimmung des Diameters der A. brachialis betrug 1,34 % für die manuelle und 0,78 % für die computergestützte Auswertung. Die Zeit für die manuelle Auswertung betrug im Mittel 35 min im Gegensatz zu 9 min für die PC-gestützte Auswertung. Schlussfolgerungen: Das automatische, PC-gestützte Analysesystem zur Vermessung von Gefäßdiametern reduziert deutlich die Variabilität und den Zeitaufwand zur Bestimmung der endothel-abhängigen Dilatation der A. brachialis. Die PC-gestützte Auswertung ermöglicht somit zukünftig die Durchführung von Screeninguntersuchungen der Endothelfunktion im klinischen Alltag und klinischen Verlaufsstudien.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
(–)-Epicatechin mediates beneficial effects of flavanol-rich cocoa on vascular function in humans
Schroeter, H., Heiss, C., Balzer, J., Kleinbongard, P., Keen, C. L., Hollenberg, N. K., Sies, H., Kwik-Uribe, C., Schmitz, H. H., & Kelm, M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0510168103 · Cited by 1,052
Self-citationThijssen, D. H. J., Bruno, R. M., van Mil, A. C. C. M., Holder, S. M., Faita, F., Greyling, A., Zock, P. L., Taddei, S., Deanfield, J. E., Luscher, T., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz350 · Cited by 995
Lauer, T., Preik, M., Rassaf, T., Strauer, B. E., Deussen, A., Feelisch, M., & Kelm, M. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.221381098 · Cited by 585
Self-citationImpaired progenitor cell activity in age-related endothelial dysfunction
Heiss, C., Keymel, S., Niesler, U., Ziemann, J., Kelm, M., & Kalka, C. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.074 · Cited by 573
Self-citation
Metadata
- Venue
- Ultraschall in der Medizin
- Publisher
- Georg Thieme Verlag KG
- Published
- 2003-11-10
- Volume
- 21
- Issue
- 05
- Pages
- 195-198
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W1985700677
- Cited by
- 55
- References
- 0
- FWCI
- 3.53
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Ultrasonic Measurement of Human Arteries for the Determination of Endothelial Function. https://app.cochat.ai/papers/10.1055/s-2000-7989
- The paper
- Automated Ultrasonic Measurement of Human Arteries for the Determination of Endothelial Function. (2003). Ultraschall in der Medizin. https://doi.org/10.1055/s-2000-7989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.