The DOI matches its Crossref record.
MATERNAL COMPLICATIONS WITH PLACENTA PREVIA
Abstract
The purpose of this study is to describe the maternal complications of placenta previa. A population-based retrospective cohort study including all women delivered in the province of Nova Scotia, Canada from 1988 to 1995 was performed. Patient information was obtained from the Nova Scotia Atlee Perinatal Database and maternal complications were described for all women undergoing cesarean delivery. Prognostic factors for the risk of hysterectomy in woman with placenta previa were analyzed by multiple logistic regression. During the 8-year period, 308 cases of placenta previa were identified in 93,996 deliveries (0.33%). Maternal complications included hysterectomy [relative risk (RR) = 33.26], antepartum bleeding (RR = 9.81), intrapartum (RR = 2.48), and postpartum (RR = 1.86) hemorrhages, as well as blood transfusion (RR = 10.05), septicemia (RR = 5.55), and thrombophlebitis (RR = 4.85). Risk factors for need of hysterectomy in women with placenta previa include the presence of placenta accreta and previous cesarean delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Faiz, A. S., & Ananth, C. V. (2003) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/jmf.13.3.175.190 · Cited by 367
Solheim, K. N., Esakoff, T. F., Little, S. E., Cheng, Y. W., Sparks, T. N., & Caughey, A. B. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.553695 · Cited by 320
Critical analysis of risk factors and outcome of placenta previa
Rosenberg, T., Pariente, G., Sergienko, R., Wiznitzer, A., & Sheiner, E. (2011) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-010-1598-7 · Cited by 259
Fan, D., Xia, Q., Liu, L., Wu, S., Tian, G., Wang, W., Wu, S., Guo, X., & Liu, Z. (2017) · PLOS ONE · doi:10.1371/journal.pone.0170194 · Cited by 115
Hong, J.-Y., Jee, Y.-S., Yoon, H.-J., & Kim, S. M. (2003) · International Journal of Obstetric Anesthesia · doi:10.1016/s0959-289x(02)00183-8 · Cited by 112
Previous prelabor or intrapartum cesarean delivery and risk of placenta previa
Downes, K. L., Hinkle, S. N., Sjaarda, L. A., Albert, P. S., & Grantz, K. L. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.01.004 · Cited by 79
A Danish national cohort study on neonatal outcome in singleton pregnancies with placenta previa
NØRGAARD, L. N., PINBORG, A., LIDEGAARD, Ø., & BERGHOLT, T. (2012) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2012.01375.x · Cited by 62
Predictors for Emergency Cesarean Delivery in Women with Placenta Previa
Eschbach, S., Burgers, M., Rengerink, K., Pampus, M., Goes, B., Mol, B., Graaf, I., Pajkrt, E., & Ruiter, L. (2016) · American Journal of Perinatology · doi:10.1055/s-0036-1584148 · Cited by 46
Sekiguchi, A., Nakai, A., Okuda, N., Inde, Y., & Takeshita, T. (2015) · Journal of Clinical Ultrasound · doi:10.1002/jcu.22205 · Cited by 41
Transabdominal Ultrasonography as a Screening Test for Second-Trimester Placenta Previa
Quant, H. S., Friedman, A. M., Wang, E., Parry, S., & Schwartz, N. (2014) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000129 · Cited by 34
Mimura, T., Hasegawa, J., Nakamura, M., Matsuoka, R., Ichizuka, K., Sekizawa, A., & Okai, T. (2011) · Journal of Obstetrics and Gynaecology Research · doi:10.1111/j.1447-0756.2010.01446.x · Cited by 33
Jansen, C. H. J. R., Kleinrouweler, C. E., Kastelein, A. W., Ruiter, L., van Leeuwen, E., Mol, B. W., & Pajkrt, E. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.21903 · Cited by 32
Berhan, Y. (2014) · Journal of Pregnancy · doi:10.1155/2014/307043 · Cited by 29
Balayla, J., Wo, B. L., & Bédard, M.-J. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2014.970529 · Cited by 25
Precise mid‐trimester placenta localisation: Does it predict adverse outcomes?
Robinson, A. J., Muller, P. R., Allan, R., Ross, R., Baghurst, P. A., & Keirse, M. J. N. C. (2012) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.2012.01416.x · Cited by 21
Metadata
- Authors
- Crane, J. M. G., Van den Hof, M. C., Dodds, L., Armson, B. A., & Liston, R.
- Venue
- American Journal of Perinatology
- Publisher
- Georg Thieme Verlag KG
- Published
- 2000
- Volume
- Volume 17
- Issue
- Number 02
- Pages
- 101-106
- ISSN
- 0735-1631 (ISSN-L)
- 1098-8785
- OpenAlex
- W2009862623
- Cited by
- 207
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.