CoChat

Evaluation of the Accusport® Lactate Analyser

Bishop, D. · 2001 · International Journal of Sports Medicine
Cited by 88

The DOI matches its Crossref record.

Abstract

It has been suggested that lactate concentrations may provide a guide to an optimal training intensity. However, lactate concentrations established during incremental exercise in the laboratory are not always indicative of what is occurring during constant-load exercise at the same intensity. Ideally, lactate concentrations should be measured during a training session and immediately reported to the athlete to ensure that the athlete is working at the desired intensity. The purpose of this investigation was, therefore, to determine the reliability and validity of a compact, portable lactate analyser (ACCUSPORT; Boeringer Mannheim, Castle Hill, Australia). A total of 224 capillary blood samples were taken from athletes who took part in routine laboratory testing. Seventy-three of these capillary blood samples were analysed in duplicate with the Accusport for determination of intraclass, single-trial reliability. Day-to-day intraclass reliability of the Accusport was assessed by analyzing known concentrations of aqueous lactate solutions on seven consecutive days. The validity of the Accusport analyser was assessed by comparing the 224 capillary blood lactate concentrations determined on the Accusport with the lactate concentration obtained using a MICRO STAT LM3 (Analox Instruments Ltd., London, UK). In addition, lactate parameters derived from the lactate concentrations obtained with the two analysers were compared. The Accusport showed high single-trial intraclass reliability (R = 0.992; Standard Error of Measurement [SE(M)] = 0.3 mmol x l(-1); n = 73) and high day-to-day intraclass reliability (R = 0.993; SE(M) = 0.4 mmol x l(-1); n = 42). Despite a strong correlation between blood lactate concentrations obtained on the two analysers (r = 0.96; n = 224) the limits of agreement were + 1.9 to - 2.2 mmol x l(-1). Although the mean values for power output, HR and lactate concentration associated with the lactate parameters were not significantly different when determined on the Accusport or Micro Stat, some individuals did record large differences between analysis methods. In summary, the results of this investigation have shown that lactate concentrations can be reliably determined within a single trial and from day-to-day using the Accusport analyser. However, for some athletes, it is not valid to compare lactate concentrations or lactate parameters determined on the Accusport with those determined using the Micro Stat LM3 lactate analyser.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2001-17611

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bishop, D.
Venue
International Journal of Sports Medicine
Published
2001-10
Volume
22
Issue
7
Pages
525-530
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2089814327
Cited by
88
References
0
FWCI
2.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.