Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems
The DOI matches its Crossref record.
Abstract
Reliability of two different spiroergometric systems was investigated by comparing gas exchange measurements from two consecutive identical bicycle ergometer ramp exercise tests which were conducted after an initial habituation trial. Twenty-three healthy subjects (age: 25+/-5 years; weight: 71+/-10 kg; peak oxygen uptake: 55+/-9 ml x min(-1) x kg(-1)) took part in the study. One apparatus was a portable mixing chamber system (MetaMax I, Cortex, Leipzig, Germany), the other one a stationary spiroergometric device measuring in the breath-by-breath mode (MetaLyzer 3B, Cortex). There were no relevant systematic changes in gas exchange measurements and heart rate from test 1 to test 2. Intra-class reliability coefficients were 0.984 (oxygen uptake = VO2), 0.977 (carbon dioxide output = VCO2), and 0.973 (minute ventilation = VE) for the MetaMax I, and 0.969 (VO2), 0.964 (VCO2), and 0.953 (VE) for the MetaLyzer 3B. Bland-Altman plots revealed a slightly smaller variability of MetaLyzer 3B measurements compared to those of MetaMax I. It is concluded that the spiroergometric devices MetaMax I and MetaLyzer 3B represent reliable instruments for exercise testing in sports medical routine and research. This is important to decide if longitudinal changes in gas exchange measurements represent clinically meaningful differences in performance or merely inconsistencies of the measuring tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Chiappa, G. R., Roseguini, B. T., Vieira, P. J. C., Alves, C. N., Tavares, A., Winkelmann, E. R., Ferlin, E. L., Stein, R., & Ribeiro, J. P. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.12.045 · Cited by 305
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
“While the reliability of the VO2000 for measuring VE is similar to other metabolic systems (Carter and Jeukendrup 2002; Larsson et al. 2004; Lucia et al. 1993; Meyer et al. 2001), the reliability for measuring VO2 and VCO2 is less than previously examined systems.”
MethodHertfordshire sarcopenia study: design and methods
Patel, H. P., Syddall, H. E., Martin, H. J., Stewart, C. E., Cooper, C., & Sayer, A. A. (2010) · BMC Geriatrics · doi:10.1186/1471-2318-10-43 · Cited by 48
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
“99) (2, 20, 25) are similar to that of the COSMED.”
Result
Metadata
- Authors
- Meyer, T., Georg, T., Becker, C., & Kindermann, W.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2001-11
- Volume
- 22
- Issue
- 8
- Pages
- 593-597
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2051788410
- Cited by
- 131
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.