CoChat

Measurement of Gastric Emptying by13C-octanoic Acid Breath Test Versus Scintigraphy in Diabetics

· 2003 · Zeitschrift für Gastroenterologie
Cited by 54

The DOI matches its Crossref record.

Abstract

In this prospective study, we compared the assessment of gastric emptying by the 13C-octanoic acid breath test to gastric emptying scintigraphy in diabetics. We also examined the relationship between gastric emptying parameters and gastric symptoms and cardiovascular autonomic function. The 13C-octanoic acid breath test and scintigraphy were performed simultaneously in 24 diabetics with a solid test meal (1 egg, doubly labelled with 91 mg 13C-octanoic acid and 50 MBq 99mTechnetium-Nanocoll, 60 g white bread, 5 g margarine and 150 ml water). At fifteen-minute intervals, breath samples were taken over 4 hours and examined by mass spectrometry. In parallel, scintigraphy was performed for 2 hours at one minute intervals. Using breath test data, gastric emptying half time (t (1/2) ), lag-phase (t lag ) and gastric emptying coefficient (GEC) were calculated. Subsequently, the correlation of these results with the equivalent data from scintigraphy were determined employing a regression method. To detect a cardiovascular autonomic neuropathy, a 24-h ECG recording was performed. The prevalence of gastrointestinal symptoms in our collective was assessed by a standardized questionnaire. There was a highly significant positive correlation of both 13C-octanoic acid breath test t (1/2) and scintigraphic t (1/2) (r = 0.8257; p < 0.0001) and 13C-octanoic acid breath test t lag and scintigraphic t lag (r = 0.6302; p < 0.001). The sensitivity of the 13C-octanoic acid breath test was 1 and the specificity was 0.73. In our study, there was no significant association of cardiovascular and gastrointestinal autonomic neuropathy. Furthermore, there was no significant relationship between the prevalence of gastrointestinal symptoms and gastric emptying disorders. We conclude that the 13C-octanoic acid breath test represents a suitable method to measure disordered gastric emptying in diabetics due to its highly significant positive correlation to scintigraphy and due to its validity. It is not possible to predict diabetic gastroparesis on the basis of other autonomic function disorders or because of dyspeptic symptoms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2003-39331

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Venue
Zeitschrift für Gastroenterologie
Published
2003-05
Volume
41
Issue
5
Pages
383-390
ISSN
  • 0044-2771 (ISSN-L)
  • 1439-7803
OpenAlex
W2406304527
Cited by
54
References
0
FWCI
3.09
Type
journal article
Language
de
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.