Measurement of Gastric Emptying by13C-octanoic Acid Breath Test Versus Scintigraphy in Diabetics
The DOI matches its Crossref record.
Abstract
In this prospective study, we compared the assessment of gastric emptying by the 13C-octanoic acid breath test to gastric emptying scintigraphy in diabetics. We also examined the relationship between gastric emptying parameters and gastric symptoms and cardiovascular autonomic function. The 13C-octanoic acid breath test and scintigraphy were performed simultaneously in 24 diabetics with a solid test meal (1 egg, doubly labelled with 91 mg 13C-octanoic acid and 50 MBq 99mTechnetium-Nanocoll, 60 g white bread, 5 g margarine and 150 ml water). At fifteen-minute intervals, breath samples were taken over 4 hours and examined by mass spectrometry. In parallel, scintigraphy was performed for 2 hours at one minute intervals. Using breath test data, gastric emptying half time (t (1/2) ), lag-phase (t lag ) and gastric emptying coefficient (GEC) were calculated. Subsequently, the correlation of these results with the equivalent data from scintigraphy were determined employing a regression method. To detect a cardiovascular autonomic neuropathy, a 24-h ECG recording was performed. The prevalence of gastrointestinal symptoms in our collective was assessed by a standardized questionnaire. There was a highly significant positive correlation of both 13C-octanoic acid breath test t (1/2) and scintigraphic t (1/2) (r = 0.8257; p < 0.0001) and 13C-octanoic acid breath test t lag and scintigraphic t lag (r = 0.6302; p < 0.001). The sensitivity of the 13C-octanoic acid breath test was 1 and the specificity was 0.73. In our study, there was no significant association of cardiovascular and gastrointestinal autonomic neuropathy. Furthermore, there was no significant relationship between the prevalence of gastrointestinal symptoms and gastric emptying disorders. We conclude that the 13C-octanoic acid breath test represents a suitable method to measure disordered gastric emptying in diabetics due to its highly significant positive correlation to scintigraphy and due to its validity. It is not possible to predict diabetic gastroparesis on the basis of other autonomic function disorders or because of dyspeptic symptoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetic gastroparesis: what we have learned and had to unlearn in the past 5 years: Figure 1
Kashyap, P., & Farrugia, G. (2010) · Gut · doi:10.1136/gut.2009.199703 · Cited by 175
“This test has been validated in subjects with diabetes.(81) Given the non-radioactive nature of the test, it can be used to measure changes in gastric emptying over time and has a sensitivity and specificity of 75% and 86%, respectively.”
MethodGastrointestinal targets of appetite regulation in humans
Delzenne, N., Blundell, J., Brouns, F., Cunningham, K., De Graaf, K., Erkner, A., Lluch, A., Mars, M., Peters, H. P. F., & Westerterp‐Plantenga, M. (2010) · Obesity Reviews · doi:10.1111/j.1467-789x.2009.00707.x · Cited by 162
The impact of admission diagnosis on gastric emptying in critically ill patients
Nguyen, N. Q., Ng, M. P., Chapman, M., Fraser, R. J., & Holloway, R. H. (2007) · Critical Care · doi:10.1186/cc5685 · Cited by 159
“Technique of GE assessment: 13C-octanoic acid breath test In all patients, the breath test was performed using an identical standardised technique [20-22].”
MethodResultInfluentialHermansen, K., Bækdal, T. A., Düring, M., Pietraszek, A., Mortensen, L. S., Jørgensen, H., & Flint, A. (2013) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12133 · Cited by 143
“Gastric emptying was assessed by the paracetamol absorption technique [18] and the 13C-octanoate breath test [19] during a test meal.”
MethodDiabetic Gastroparesis: Diagnosis and Management
Ma, J., Rayner, C. K., Jones, K. L., & Horowitz, M. (2009) · Drugs · doi:10.2165/00003495-200969080-00003 · Cited by 87
“[84] Breath tests correlate well with scintigraphy in healthy volunteers and patients with diabetes,([85,86]) with a sensitivity and specificity of ‡80% for detecting delayed gastric emptying.”
Bonetto, S., Gruden, G., Beccuti, G., Ferro, A., Saracco, G. M., & Pellicano, R. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10061313 · Cited by 26
13C‐gastric emptying breath tests: Clinical use in adults and children
Keller, J., Hammer, H. F., & Hauser, B. (2021) · Neurogastroenterology & Motility · doi:10.1111/nmo.14172 · Cited by 15
Metadata
- Venue
- Zeitschrift für Gastroenterologie
- Publisher
- Georg Thieme Verlag KG
- Published
- 2003-05
- Volume
- 41
- Issue
- 5
- Pages
- 383-390
- ISSN
- 0044-2771 (ISSN-L)
- 1439-7803
- OpenAlex
- W2406304527
- Cited by
- 54
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.