Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity
The DOI matches its Crossref record.
Abstract
The purpose of this study was to establish the accuracy of five published accelerometer regression equations that predict time spent in different intensity classifications during free-living activities. Ten participants completed physical tasks in a field setting for a near-continuous 5 - 6 h-period while oxygen uptake and accelerometer data were collected. The amount of time spent in resting/light, moderate and hard activity was computed from 3 and 6 MET cut-points associated with five existing regression formulas relating accelerometer counts x min -1 to energy expenditure. The Freedson cut-points over-estimated resting/light activity by 34 min (13 %) and under-estimated moderate activity by 38 min (60 %). The Hendelman cut-points for all activities underestimated resting/light activity by 77 min (29 %), and overestimated moderate activity by 77 min (120 %). The Hendelman cut-points developed from walking activities over-estimated resting/light activity by 37 min (14 %) and under-estimated moderate activity by 38 min (60 %). Estimates from the Swartz cut-points for estimating time spent in resting/light, moderate and hard intensity activity were not different from the criterion measure. The Nichols cut-points over-estimated resting/light activity by 31 min (12 %) and under-estimated moderate activity by 35 min (55 %). Even though the Swartz method did not differ from measured time spent in moderate activity on a group basis, on an individual basis, large errors were seen. This was true for all regression formulas. These errors highlight some of the limitations to using hip-mounted accelerometers to reflect physical activity patterns. The finding that different accelerometer cut-points gave substantially different estimates of time spent data has important implications for researchers using accelerometers to predict time spent in different intensity categories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lee, P. H., Macfarlane, D. J., Lam, T., & Stewart, S. M. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-115 · Cited by 3,370
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Self-citationReliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Healy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2007) · Diabetes Care · doi:10.2337/dc07-0114 · Cited by 627
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Metadata
- Authors
- Strath, S., Bassett, D., & Swartz, A.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2003-06-04
- Volume
- 24
- Issue
- 04
- Pages
- 298-303
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2403674276
- Cited by
- 110
- References
- 0
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity. https://app.cochat.ai/papers/10.1055/s-2003-39504
- The paper
- Strath, S., Bassett, D., & Swartz, A. (2003). Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity. International Journal of Sports Medicine. https://doi.org/10.1055/s-2003-39504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.