CoChat

Can Visual Distraction Decrease the Dose of Patient-Controlled Sedation Required During Colonoscopy? A Prospective Randomized Controlled Trial

Lee, D., Chan, A., Wong, S., Fung, T., Li, A., Chan, S., Mui, L., Ng, E., Chung, S. · 2004 · Endoscopy
Cited by 122

The DOI matches its Crossref record.

Abstract

BACKGROUND AND STUDY AIMS: We previously demonstrated that audio distraction using relaxation music could lead to a decrease in the dose of sedative medication required and improve patient satisfaction during colonoscopy. This prospective randomized controlled trial was designed to test the hypotheses that visual distraction may also decrease the requirement for sedatives and that audio and visual distraction may have additive beneficial effects when used in combination. PATIENTS AND METHODS: 165 consecutive patients who underwent elective colonoscopy were randomly allocated into three groups to receive different modes of sedation: group 1 received visual distraction and patient-controlled sedation (PCS); group 2 received audiovisual distraction and PCS; group 3 received PCS alone. A mixture of propofol and alfentanil, delivered by a Graseby 3300 PCA pump, was used for PCS in these groups. Each bolus of PCS delivered 4.8 mg propofol and 12 micro g alfentanil. Measured outcomes included the dose of PCS used, complications, recovery time, pain score, satisfaction score, and willingness to use the same mode of sedation if the procedure were to be repeated. RESULTS: Eight patients were excluded after randomization. The mean+/-SD dose of propofol used in group 2 (0.81 mg/kg +/- 0.49) was significantly less than the dose used in group 1 (1.17 mg/kg +/- 0.81) and that used in group 3 (1.18 mg/kg +/- 0.60) ( P < 0.01, one-way analysis of variance). The mean +/- SD pain score was also lower in group 2 (5.1 +/- 2.5), compared with the pain scores in group 1 (6.2 +/- 2.2) and group 3 (7.0 +/- 2.4) ( P < 0.01, one-way analysis of variance). The mean +/- SD satisfaction score was higher in groups 1 (8.2 +/- 2.4)) and 2 (8.4 +/- 2.4), compared with the score in group 3 (6.1 +/- 2.9) ( P < 0.01, one-way analysis of variance). A majority of patients in groups 1 (73 %) and 2 (85 %) said that they would be willing to use the same mode of sedation again, compared with only 53 % in group 3 ( P < 0.01, chi-squared test). CONCLUSIONS: Visual distraction alone did not decrease the dose of sedative medication required for colonoscopy. When audio distraction was added, both the dose of sedative medication required and the pain score decreased significantly. Both visual and audiovisual distraction might improve patients' acceptance of colonoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2004-814247

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Lee, D., Chan, A., Wong, S., Fung, T., Li, A., Chan, S., Mui, L., Ng, E., & Chung, S.
Venue
Endoscopy
Published
2004-02-26
Volume
36
Issue
03
Pages
197-201
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2102289488
Cited by
122
References
0
FWCI
4.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can Visual Distraction Decrease the Dose of Patient-Controlled Sedation Required During Colonoscopy? A Prospective Randomized Controlled Trial. https://app.cochat.ai/papers/10.1055/s-2004-814247
The paper
Lee, D., Chan, A., Wong, S., Fung, T., Li, A., Chan, S., Mui, L., Ng, E., & Chung, S. (2004). Can Visual Distraction Decrease the Dose of Patient-Controlled Sedation Required During Colonoscopy? A Prospective Randomized Controlled Trial. Endoscopy. https://doi.org/10.1055/s-2004-814247

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.