The DOI matches its Crossref record.
Narrow-Band Imaging in the Diagnosis of Colorectal Mucosal Lesions: A Pilot Study
Abstract
BACKGROUND AND STUDY AIMS: A newly developed narrow-band imaging (NBI) technique, in which modified optical filters were used in the light source of a video endoscope system, was applied during colonoscopy in a clinical setting. This pilot study evaluated the clinical feasibility of the NBI system for evaluating colorectal lesions. PATIENTS AND METHODS: A total of 43 colorectal lesions in 34 patients were included in the study. The quality of visualization of colorectal lesions and the accuracy of differentiation between neoplastic and non-neoplastic lesions using the NBI system were evaluated in comparison with results from conventional colonoscopy and with chromoendoscopy. RESULTS: For pit pattern delineation, NBI was superior to conventional endoscopy (P < 0.001), but inferior to chromoendoscopy (P < 0.05). NBI achieved better visualization of the mucosal vascular network and of the hue of lesions than conventional endoscopy (P < 0.05). However there was no significant difference between NBI and chromoendoscopy in differentiating neoplastic from non-neoplastic lesions (both techniques had a sensitivity of 100 % and a specificity 75 %). This was better than the results of conventional colonoscopy (sensitivity 83 %, specificity 44 %; P < 0.05 for specificity). CONCLUSIONS: These results suggest that in the examination of colonic lesions the NBI system provides imaging features additional to those of both conventional endoscopy and chromoendoscopy. For distinguishing neoplasms from non-neoplastic lesions, NBI was equivalent to chromoendoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Benchmark for Endoluminal Scene Segmentation of Colonoscopy Images
Vázquez, D., Bernal, J., Sánchez, F. J., Fernández-Esparrach, G., López, A. M., Romero, A., Drozdzal, M., & Courville, A. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/4037190 · Cited by 866
Muto, M., Minashi, K., Yano, T., Saito, Y., Oda, I., Nonaka, S., Omori, T., Sugiura, H., Goda, K., Kaise, M., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.25.4680 · Cited by 699
Self-citationSano, Y., Tanaka, S., Kudo, S., Saito, S., Matsuda, T., Wada, Y., Fujii, T., Ikematsu, H., Uraoka, T., Kobayashi, N., et al. (2016) · Digestive Endoscopy · doi:10.1111/den.12644 · Cited by 617
Self-citationHewett, D. G., Kaltenbach, T., Sano, Y., Tanaka, S., Saunders, B. P., Ponchon, T., Soetikno, R., & Rex, D. K. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.05.006 · Cited by 592
Self-citationHayashi, N., Tanaka, S., Hewett, D. G., Kaltenbach, T. R., Sano, Y., Ponchon, T., Saunders, B. P., Rex, D. K., & Soetikno, R. M. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.04.185 · Cited by 485
Self-citationDetection of colonic dysplasia in vivo using a targeted heptapeptide and confocal microendoscopy
Hsiung, P.-L., Hardy, J., Friedland, S., Soetikno, R., Du, C. B., Wu, A. P., Sahbaie, P., Crawford, J. M., Lowe, A. W., Contag, C. H., et al. (2008) · Nature Medicine · doi:10.1038/nm1692 · Cited by 444
Bernal, J., Tajkbaksh, N., Sanchez, F. J., Matuszewski, B. J., Chen, H., Yu, L., Angermann, Q., Romain, O., Rustad, B., Balasingham, I., et al. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2664042 · Cited by 437
Rex, D. K., & Helbig, C. C. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.04.029 · Cited by 386
Zhang, R., Zheng, Y., Mak, T. W. C., Yu, R., Wong, S. H., Lau, J. Y. W., & Poon, C. C. Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2635662 · Cited by 374
Ignjatovic, A., East, J. E., Suzuki, N., Vance, M., Guenther, T., & Saunders, B. P. (2009) · The Lancet Oncology · doi:10.1016/s1470-2045(09)70329-8 · Cited by 368
The utility of a novel narrow band imaging endoscopy system in patients with Barrett's esophagus
Sharma, P., Bansal, A., Mathur, S., Wani, S., Cherian, R., McGregor, D., Higbee, A., Hall, S., & Weston, A. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.10.044 · Cited by 364
Chiu, H.-M., Chang, C.-Y., Chen, C.-C., Lee, Y.-C., Wu, M.-S., Lin, J.-T., Shun, C.-T., & Wang, H.-P. (2007) · Gut · doi:10.1136/gut.2006.099614 · Cited by 324
Sano, Y., Ikematsu, H., Fu, K. I., Emura, F., Katagiri, A., Horimatsu, T., Kaneko, K., Soetikno, R., & Yoshida, S. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.04.066 · Cited by 290
Self-citationNarrow-Band Imaging Without Optical Magnification for Histologic Analysis of Colorectal Polyps
Rex, D. K. (2009) · Gastroenterology · doi:10.1053/j.gastro.2008.12.009 · Cited by 261
Su, M.-Y., Hsu, C.-M., Ho, Y.-P., Chen, P.-C., Lin, C.-J., & Chiu, C.-T. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00932.x · Cited by 256
Accuracy for Optical Diagnosis of Small Colorectal Polyps in Nonacademic Settings
Kuiper, T., Marsman, W. A., Jansen, J. M., van Soest, E. J., Haan, Y. C. L., Bakker, G. J., Fockens, P., & Dekker, E. (2012) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2012.05.004 · Cited by 110
Nakai, K., Lin, H., Yamano, S., Tanaka, S., Kitamoto, S., Saitoh, H., Sakuma, K., Kurauchi, J., Akter, E., Konno, M., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42774-6 · Cited by 14
Bernhofer, S., Prosenz, J., Duller, C., Venturi, D., & Maieron, A. (2026) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000003558 · Cited by 4
Metadata
- Authors
- Machida, H., Sano, Y., Hamamoto, Y., Muto, M., Kozu, T., Tajiri, H., & Yoshida, S.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2004-12
- Volume
- 36
- Issue
- 12
- Pages
- 1094-1098
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W1973980483
- Cited by
- 520
- References
- 0
- FWCI
- 9.84
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.