The Kinetics of Insulin Administration by Insulin Pens
The DOI matches its Crossref record.
Abstract
Insulin pens deliver insulin more slowly than syringes because of compressible elements of the insulin cartridges, especially air bubbles. The time required for a pen to deliver 20 Units of insulin increased with increasing air in the cartridge as determined by two independent techniques. The first technique involved no back pressure and was done by injection of [125I]-iodoinsulin onto absorbent paper on a constant angular velocity turntable. The second technique involved the normal back pressure of subcutaneous tissue and was done by robotic, timed injections of [125I]-iodoinsulin into full thickness pigskin. Air dramatically reduced the delivery of insulin in the five seconds that patients normally wait for injection by an insulin pen. Accumulation of more than 50 microliters of air results in a delivery of an unacceptably low percentage of insulin: with 200 microliters of air, a patient would get only 37% of the expected dose. Thus, a patient who injects 20 Units of insulin and withdraws the needle after the recommended 5 seconds would receive only 7.4 Units if there were 200 microliters of air in the cartridge. Since we found that 42 of 50 commercially available insulin cartridges contained air bubbles at purchase (average estimated to be 50 microliters), additional air entering the cartridge could lead to serious underdosing. Previous studies have demonstrated that air accumulates in insulin cartridges when the needle is left on the pen between injections. Therefore, for safety reasons, patients should be strongly advised to remove the needle immediately after each injection as recommended by the manufacturer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
“After that, the button should be pressed along the axis of the pen, not at an angle.(99) A2”
BackgroundDanne, T., Phillip, M., Buckingham, B. A., Jarosz-Chobot, P., Saboo, B., Urakami, T., Battelino, T., Hanas, R., & Codner, E. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12718 · Cited by 225
“A delay of 15 seconds after pushing in the plunger helps to ensure complete expulsion of insulin through the needle.(110)”
BackgroundInadequate suspension of neutral protamine Hagendorn (NPH) insulin in pens
Jehle, P. M., Micheler, C., Jehle, D. R., Breitig, D., & Boehm, B. O. (1999) · The Lancet · doi:10.1016/s0140-6736(98)12459-5 · Cited by 186
New injection recommendations for patients with diabetes
Frid, A., Hirsch, L., Gaspar, R., Hicks, D., Kreugel, G., Liersch, J., Letondeur, C., Sauvanet, J. P., Tubiana-Rufi, N., & Strauss, K. (2010) · Diabetes & Metabolism · doi:10.1016/s1262-3636(10)70002-1 · Cited by 172
Insulclock : A Novel Insulin Delivery Optimization and Tracking System
Gomez-Peralta, F., Abreu, C., Gomez-Rodriguez, S., & Ruiz, L. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0361 · Cited by 30
“39 This evidence should encourage users to follow insulin storage recommendations and inspect the cartridges for any visual change indicative of insulin degradation before each administration, 39,40 but these inspections are subjective and recommendations can vary from one manufacturer to another.”
Cengiz, E., Danne, T., Ahmad, T., Ayyavoo, A., Beran, D., Codner, E., Ehtisham, S., Jarosz-Chobot, P., Mungai, L. N. W., Ng, S. M., et al. (2025) · Hormone Research in Paediatrics · doi:10.1159/000543169 · Cited by 17
“(cid:129) There should be a delay of 15 s after pushing in the plunger to help ensure complete expulsion of insulin through the needle [127].”
Metadata
- Authors
- Ginsberg, B., Parkes, J., & Sparacino, C.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 1994-12
- Volume
- 26
- Issue
- 12
- Pages
- 584-587
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W2078492471
- Cited by
- 54
- References
- 0
- FWCI
- 0.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.