Estimates of In Vivo Insulin Action in Humans: Comparison of the Insulin Clamp and the Minimal Model Techniques
The DOI matches its Crossref record.
Abstract
The insulin clamp technique, which is often assumed to measure the ability of insulin to stimulate glucose uptake, actually measures both insulin-independent and insulin-dependent glucose uptake. In contrast, the minimal model technique, recently introduced by Bergman, Philips and Cobelli (1981), attempts to directly estimate insulin sensitivity (insulin-dependent glucose uptake = S1) by measurement of plasma glucose and insulin values during a 3 hour intravenous glucose tolerance test (IVGTT). In the present study estimates of insulin action derived from the insulin clamp and the minimal model technique were compared in 20 humans with varying degrees of glucose tolerance. The insulin response during the IVGTT was too low to permit calculation of S1 in 5 subjects - 4 with Type II diabetes and 1 with normal glucose tolerance. Although the correlation coefficient between the two tests in the other 15 patients was statistically significant (r = 0.53, P less than 0.05), this statement is somewhat misleading. Thus, S1 in the 4/7 patients with Type II diabetes in whom it could be measured was zero, and the correlation between estimates of insulin action with the two techniques in the 11 non-diabetic patients was not statistically significant (r = 0.41, P = NS) when these 4 patients were removed from the analysis. In conclusion, these data indicate that there was only a weak correlation between estimates of insulin action assessed with the insulin clamp and the minimal model techniques. One explanation for this observation is that the insulin-independent component of total glucose disposal both varies widely among patients and contributes significantly to glucose uptake as assessed by the insulin clamp technique.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Katz, A., Nambi, S. S., Mather, K., Baron, A. D., Follmann, D. A., Sullivan, G., & Quon, M. J. (2000) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.85.7.6661 · Cited by 3,931
Bergman, R. N., Prager, R., Volund, A., & Olefsky, J. M. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112886 · Cited by 772
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Evaluation of insulin sensitivity in clinical practice and in research settings
Monzillo, L. U., & Hamdy, O. (2003) · Nutrition Reviews · doi:10.1301/nr.2003.dec.397-412 · Cited by 259
Metadata
- Authors
- Foley, J., Chen, Y.-D. I., Lardinois, C., Hollenbeck, C., Liu, G., & Reaven, G.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 1985-08
- Volume
- 17
- Issue
- 08
- Pages
- 406-409
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W1994632284
- Cited by
- 34
- References
- 0
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.