The Reliability of Lactate Measurements During Exercise
The DOI matches its Crossref record.
Abstract
The purpose of this study was to establish the reliability of lactate threshold (LT) measurement across days. Twelve endurance-trained males aged 21-44 years participated in the study. Blood lactate concentration in capillary whole blood was measured at rest and at completion of 5 minute stages on a treadmill at 60%, 65%, 71%, 77%, 83% and 89% of VO2max during 3 separate days of testing. Velocity at LT (LT(VEL)), oxygen consumption at LT (LT(VO2)), and heart rate at LT (LT(HR)) are determined using each of the following criteria: fixed lactate concentrations of 2.0 mmol, 2.5 mmol, and 4.0 mmol, the breakpoint of the lactate-intensity curve, 1 mmol above rest, and 1 mmol above exercise baseline. A one factor repeated measures ANOVA model was used to calculate intraclass reliability coefficients across the 3 testing sessions. Confidence intervals (95%) were calculated around the point estimates of reliability for each LT criterion. Intraclass correlation coefficients ranged from 0.98 to 0.99 LT(VEL) (SEM 0.06 to 0.14 km x hr(-1)), from 0.91 to 0.96 for LT(VO2) (SEM 0.34 to 0.72 ml x kg(-1) x min(-1)), and from 0.75 to 0.96 for LTHR (SEM 0.7 to 1.9 beats x min(-1)). These results support the reliability of LT(VEL), LT(VO2), and LT(HR) measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Design and analysis of research on sport performance enhancement
HOPKINS, W. G., HAWLEY, J. A., & BURKE, L. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199903000-00018 · Cited by 708
Bentley, D. J., Newell, J., & Bishop, D. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00002 · Cited by 404
Evaluation of the Lactate Pro blood lactate analyser
Pyne, D. B., Boston, T., Martin, D. T., & Logan, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050659 · Cited by 313
Validity and reliability of ventilatory and blood lactate thresholds in well-trained cyclists
Pallarés, J. G., Morán-Navarro, R., Ortega, J. F., Fernández-Elías, V. E., & Mora-Rodriguez, R. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163389 · Cited by 180
Scharhag‐Rosenberger, F., Walitzek, S., Kindermann, W., & Meyer, T. (2012) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01139.x · Cited by 118
“As no CV for the IAT according to Stegmann et al. (1981) has been published, an average CV of six other LT concepts of 1.9% was used (Pfitzinger & Freedson, 1998).”
MethodInfluentialReliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise
Austin, K. G., Daigle, K. A., Patterson, P., Cowman, J., Chelland, S., & Haymes, E. M. (2005) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2005.10599317 · Cited by 58
Metadata
- Authors
- Pfitzinger, P., & Freedson, P.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1998-07
- Volume
- 19
- Issue
- 05
- Pages
- 349-357
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2058163507
- Cited by
- 73
- References
- 0
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.