The DOI matches its Crossref record.
Kinematics and Electromyography of Lower Limb Muscles in Overground and Treadmill Running
Abstract
Treadmills are often used in research to analyse kinematic and physiological variables. The success of transfering the results to overground running depends on the comparability of the values between the two situations. The aim of the present study was to compare the kinematics and muscle activities in overground and treadmill running. Ten male physical education students with experience in treadmill running were asked to run with a speed of 4.0 and 6.0 m/s both overground and on a Woodway treadmill. The 3D-kinematics of the limbs were studied using a two camera video tracking system. Additionally the surface EMG of six lower limb muscles and the pattern of ground contact of the right foot was registered. Both the activities of the leg muscles and several kinematic variables showed systematic changes from overground to treadmill running. On the treadmill the subjects favoured a type of running that provided them with a higher level of security. The swing amplitude of the leg, the vertical displacement and the variance in vertical and horizontal velocity were lower in treadmill running. The angle between shoe sole and ground at foot impact was also lower and the forward lean of the upper body was higher in running on the treadmill compared with the overground mode. Most of the subjects reduced their step length and increased stride frequency in treadmill running. Furthermore, the contact time in treadmill running was shorter than for overground running. The above mentioned kinematic variables were significantly different (p < 0.05). The EMG patterns of the leg muscles were generally similar between overground and treadmill modes, but some minor differences could consistently be identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Local Dynamic Stability Versus Kinematic Variability of Continuous Overground and Treadmill Walking
Dingwell, J. B., Cusumano, J. P., Cavanagh, P. R., & Sternad, D. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1336798 · Cited by 663
Dingwell, J. B., & Marin, L. C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.014 · Cited by 626
Is movement variability important for sports biomechanists?
Bartlett, R., Wheat, J., & Robins, M. (2007) · Sports Biomechanics · doi:10.1080/14763140701322994 · Cited by 538
A Kinematics and Kinetic Comparison of Overground and Treadmill Running
RILEY, P. O., DICHARRY, J., FRANZ, J., CROCE, U. D., WILDER, R. P., & KERRIGAN, D. C. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181677530 · Cited by 463
Hamner, S. R., & Delp, S. L. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.11.024 · Cited by 319
Metadata
- Authors
- Wank, V., Frick, U., & Schmidtbleicher, D.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1998-10
- Volume
- 19
- Issue
- 07
- Pages
- 455-461
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2015715906
- Cited by
- 222
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinematics and Electromyography of Lower Limb Muscles in Overground and Treadmill Running. https://app.cochat.ai/papers/10.1055/s-2007-971944
- The paper
- Wank, V., Frick, U., & Schmidtbleicher, D. (1998). Kinematics and Electromyography of Lower Limb Muscles in Overground and Treadmill Running. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-971944
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.