The DOI matches its Crossref record.
Reliability and Precision of Isokinetic Strength and Muscular Endurance for the Quadriceps and Hamstrings
Abstract
The importance of accurately reproducing isokinetic strength values is critical for the assessment of training induced changes in muscle function. The purpose of this study was to determine the test re-test reliability of the Biodex System 2 Isokinetic Dynamometer for concentric quadricep and hamstring strength and muscular endurance. Twenty-one healthy volunteers underwent isokinetic testing on 2 occasions separated by 7 days. Each subject performed 5 repetitions at 60 degrees/ second followed by a muscular endurance test which consisted of 30 repetitions at 180 degrees/second. The results demonstrated high ICC values ranging from r = 0.88 to r = 0.97 and r = 0.82 to r = 0.96 for variables measured at 60 degrees/second and 180 degrees/second, respectively, SEM values were found to range from low to moderate, 4.8% to 11.6% and 5.6% to 10.8%, at 60 and 180 degrees/second, respectively. ICC coefficients were found to be low, r = 0.52 to r = 0.74, and SEM values were found to be high, 9.8% to 20.8%, for the work fatigue index at 180 degrees/second. The results demonstrate that isokinetic values obtained at 60 and 180 degrees/second are highly reproducible with the Biodex System 2 Dynamometer provided that adequate calibration, gravity correction and patient positioning is recorded and standardized. However, the work fatigue index as a measure of muscular endurance has not been shown to be reliable or precise. Changes in muscular strength over time should be considered valid if these differences lie beyond the SEM values reported in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Risk factors for sports injuries — a methodological approach
Bahr, R., & Holme, I. (2003) · British Journal of Sports Medicine · doi:10.1136/bjsm.37.5.384 · Cited by 902
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Relationship between Hip and Knee Strength and Knee Valgus during a Single Leg Squat
Claiborne, T. L., Armstrong, C. W., Gandhi, V., & Pincivero, D. M. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.1.41 · Cited by 376
Self-citationTest-Retest Reliability of Isokinetic Knee Extension and Flexion
Sole, G., Hamrén, J., Milosavljevic, S., Nicholson, H., & Sullivan, S. J. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.02.006 · Cited by 284
Danneskiold‐Samsøe, B., Bartels, E. M., Bülow, P. M., Lund, H., Stockmarr, A., Holm, C. C., Wätjen, I., Appleyard, M., & Bliddal, H. (2009) · Acta Physiologica · doi:10.1111/j.1748-1716.2009.02022.x · Cited by 280
Metadata
- Authors
- Pincivero, D., Lephart, S., & Karunakara, R.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1997-02
- Volume
- 18
- Issue
- 02
- Pages
- 113-117
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2065979506
- Cited by
- 229
- References
- 0
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Precision of Isokinetic Strength and Muscular Endurance for the Quadriceps and Hamstrings. https://app.cochat.ai/papers/10.1055/s-2007-972605
- The paper
- Pincivero, D., Lephart, S., & Karunakara, R. (1997). Reliability and Precision of Isokinetic Strength and Muscular Endurance for the Quadriceps and Hamstrings. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-972605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.