CoChat

High Frequency of Unrecognized Hypoglycaemias in Patients with Type 2 Diabetes is Discovered by Continuous Glucose Monitoring

Weber, K., Lohmann, T., Busch, K., Donati-Hirsch, I., Riel, R. · 2007 · Experimental and Clinical Endocrinology & Diabetes
Cited by 59

The DOI matches its Crossref record.

Abstract

AIMS: To evaluate the use of a CGMS in the detection of hypoglycaemia in people with type 2 diabetes as an outpatient procedure. METHODS: 31 type 2 diabetic patients underwent glucose monitoring by means of CGMS (Medtronic MiniMed) for up to three days. Patients took part in at least four SMBG (self monitoring blood glucose) tests per day. After three days of monitoring, the CGMS data was downloaded and analysed by a physician to identify the frequency of hypoglycaemias (< or =50 mg/dl) and borderline values (51-70 mg/dl), their duration and distribution. Findings were discussed with the patient and if necessary treatment was adjusted. Eight weeks later, monitoring was repeated to asses the effects of the adjusted treatment. RESULTS: Average duration of sensor wear was 4.19 days. Correlation between the sensor and the SMBG readings was high. A high number of hypoglycaemias and borderline values were detected by the CGMS, most of them unrecognized by the patient. The frequency of hypoglycaemias and borderline values just as the duration could be significantly reduced from first to second monitoring. CONCLUSION: Using the CGMS in type 2 diabetic patients achieved the detection of numerous hypoglycaemias and borderline values both nocturnal and/or unnoticed. The CGMS provides accurate data, which cannot be achieved by conventional SMBG tests. That opens the possibility for treatment adjustment and improvement in metabolic control. For patients it provides a better understanding of the effects of insulin or oral agents, nutrition and exercises to their glucose level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-984452

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 59

Metadata

Authors
Weber, K., Lohmann, T., Busch, K., Donati-Hirsch, I., & Riel, R.
Venue
Experimental and Clinical Endocrinology & Diabetes
Published
2007-09-12
Volume
115
Issue
08
Pages
491-494
ISSN
  • 0947-7349 (ISSN-L)
  • 1439-3646
OpenAlex
W2086595398
Cited by
59
References
0
FWCI
2.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Frequency of Unrecognized Hypoglycaemias in Patients with Type 2 Diabetes is Discovered by Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.1055/s-2007-984452
The paper
Weber, K., Lohmann, T., Busch, K., Donati-Hirsch, I., & Riel, R. (2007). High Frequency of Unrecognized Hypoglycaemias in Patients with Type 2 Diabetes is Discovered by Continuous Glucose Monitoring. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-2007-984452

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.