Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 512

The DOI matches its Crossref record.

Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies

Heresbach, D., Barrioz, T., Lapalus, M., Coumaros, D., Bauret, P., Potier, P., Sautereau, D., Boustière, C., Grimaud, J., Barthélémy, C., Sée, J., Serraj, I., D’Halluin, P., Branger, B., Ponchon, T. · 2008 · Endoscopy

Abstract

BACKGROUND AND STUDY AIM: Polyp miss rates during colonoscopy have been calculated in a few tandem or back-to-back colonoscopy studies. Our objective was to assess the adenoma miss rate while limiting technique or operator expertise biases, i. e. by performing a large multicenter study, with same-day back-to-back video colonoscopy, done by two different operators in randomized order and blinded to the other examination. PATIENTS AND METHODS: 294 patients at 11 centers were included. Among the 286 analyzable tandem colonoscopies, miss rates were calculated in both a lesion- and patient-based analysis. Each of these rates was determined for polyps overall, for adenomas, and then for lesions larger than 5 mm, and for advanced adenomas. Univariate and logistic regression analysis were performed to define independent variables associated with missed polyps or adenomas. RESULTS: The miss rates for polyps, adenomas, polyps > or = 5 mm, adenomas > or = 5 mm, and advanced adenomas were, respectively, 28 %, 20 %, 12 %, 9 % and 11 %. None of the masses with a carcinomatous (n = 3) or carcinoid component (n = 1) was missed. The specific lesion miss rates for patients with polyps and adenomas were respectively 36 % and 26 % but the corresponding rates were 23 % and 9.4 % when calculated for all 286 patients. The diameter (1-mm increments) and number of polyps (> or = 3) were independently associated with a lower polyp miss rate, whereas sessile or flat shape and left location were significantly associated with a higher miss rate. Adequacy of cleansing, presence of diverticula, and duration of withdrawal for the first procedure were not associated with adenoma miss rate. CONCLUSIONS: We confirm a significant miss rate for polyps or adenoma during colonoscopy. Detection of flat polyps is an issue that must be focused on to improve the quality of colonoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-995618

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 512

Metadata

Authors
Heresbach, D., Barrioz, T., Lapalus, M., Coumaros, D., Bauret, P., Potier, P., Sautereau, D., Boustière, C., Grimaud, J., Barthélémy, C., Sée, J., Serraj, I., D’Halluin, P., Branger, B., & Ponchon, T.
Venue
Endoscopy
Published
2008-04-04
Volume
40
Issue
04
Pages
284-290
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2054367831
Cited by
512
References
0
FWCI
13.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies. https://app.cochat.ai/papers/10.1055/s-2007-995618
The paper
Heresbach, D., Barrioz, T., Lapalus, M., Coumaros, D., Bauret, P., Potier, P., Sautereau, D., Boustière, C., Grimaud, J., Barthélémy, C., Sée, J., Serraj, I., D’Halluin, P., Branger, B., & Ponchon, T. (2008). Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies. Endoscopy. https://doi.org/10.1055/s-2007-995618

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.