Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies
The DOI matches its Crossref record.
Abstract
BACKGROUND AND STUDY AIM: Polyp miss rates during colonoscopy have been calculated in a few tandem or back-to-back colonoscopy studies. Our objective was to assess the adenoma miss rate while limiting technique or operator expertise biases, i. e. by performing a large multicenter study, with same-day back-to-back video colonoscopy, done by two different operators in randomized order and blinded to the other examination. PATIENTS AND METHODS: 294 patients at 11 centers were included. Among the 286 analyzable tandem colonoscopies, miss rates were calculated in both a lesion- and patient-based analysis. Each of these rates was determined for polyps overall, for adenomas, and then for lesions larger than 5 mm, and for advanced adenomas. Univariate and logistic regression analysis were performed to define independent variables associated with missed polyps or adenomas. RESULTS: The miss rates for polyps, adenomas, polyps > or = 5 mm, adenomas > or = 5 mm, and advanced adenomas were, respectively, 28 %, 20 %, 12 %, 9 % and 11 %. None of the masses with a carcinomatous (n = 3) or carcinoid component (n = 1) was missed. The specific lesion miss rates for patients with polyps and adenomas were respectively 36 % and 26 % but the corresponding rates were 23 % and 9.4 % when calculated for all 286 patients. The diameter (1-mm increments) and number of polyps (> or = 3) were independently associated with a lower polyp miss rate, whereas sessile or flat shape and left location were significantly associated with a higher miss rate. Adequacy of cleansing, presence of diverticula, and duration of withdrawal for the first procedure were not associated with adenoma miss rate. CONCLUSIONS: We confirm a significant miss rate for polyps or adenoma during colonoscopy. Detection of flat polyps is an issue that must be focused on to improve the quality of colonoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
“Polyp miss-rates are estimated to be about 4% to 12% [43]– [46]; however, a more recent clinical study [47] is suggestive that this misdetection rate may be as high as 25%.”
BackgroundAutomated Polyp Detection in Colonoscopy Videos Using Shape and Context Information
Tajbakhsh, N., Gurudu, S. R., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2487997 · Cited by 1,203
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Protection From Right- and Left-Sided Colorectal Neoplasms After Colonoscopy: Population-Based Study
Brenner, H., Hoffmeister, M., Arndt, V., Stegmaier, C., Altenhofen, L., & Haug, U. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djp436 · Cited by 573
Nonpolypoid neoplastic lesions of the colorectal mucosa
Kudo, S. E., Lambert, R., Allen, J. I., Fujii, H., Fujii, T., Kashida, H., Matsuda, T., Mori, M., Saito, H., Shimoda, T., et al. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.07.052 · Cited by 530
Wang, P., Xiao, X., Glissen Brown, J. R., Berzin, T. M., Tu, M., Xiong, F., Hu, X., Liu, P., Song, Y., Zhang, D., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0301-3 · Cited by 483
Lebwohl, B., Kastrinos, F., Glick, M., Rosenbaum, A. J., Wang, T., & Neugut, A. I. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.01.051 · Cited by 466
Graser, A., Stieber, P., Nagel, D., Schafer, C., Horst, D., Becker, C. R., Nikolaou, K., Lottes, A., Geisbusch, S., Kramer, H., et al. (2009) · Gut · doi:10.1136/gut.2008.156448 · Cited by 389
Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy
Chokshi, R. V., Hovis, C. E., Hollander, T., Early, D. S., & Wang, J. S. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.01.005 · Cited by 362
Jha, D., Smedsrud, P. H., Johansen, D., de Lange, T., Johansen, H. D., Halvorsen, P., & Riegler, M. A. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3049304 · Cited by 345
Rembacken, B., Hassan, C., Riemann, J., Chilton, A., Rutter, M., Dumonceau, J.-M., Omar, M., & Ponchon, T. (2012) · Endoscopy · doi:10.1055/s-0032-1325686 · Cited by 333
Self-citationEndoscopic Improvement of the Adenoma Detection Rate during Colonoscopy - Where Do We Stand in 2015?
Floer, M., & Meister, T. (2016) · Digestion · doi:10.1159/000442464 · Cited by 300
van Leerdam, M. E., Roos, V. H., van Hooft, J. E., Dekker, E., Jover, R., Kaminski, M. F., Latchford, A., Neumann, H., Pellisé, M., Saurin, J.-C., et al. (2019) · Endoscopy · doi:10.1055/a-0965-0605 · Cited by 258
Wang, P., Liu, P., Glissen Brown, J. R., Berzin, T. M., Zhou, G., Lei, S., Liu, X., Li, L., & Xiao, X. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.06.023 · Cited by 231
An Endoscopic Quality Improvement Program Improves Detection of Colorectal Adenomas
Coe, S. G., Crook, J. E., Diehl, N. N., & Wallace, M. B. (2013) · American Journal of Gastroenterology · doi:10.1038/ajg.2012.417 · Cited by 195
Interval colorectal cancer after colonoscopy: exploring explanations and solutions
Adler, J., & Robertson, D. J. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.365 · Cited by 129
Aniwan, S., Orkoonsawat, P., Viriyautsahakul, V., Angsuwatcharakon, P., Pittayanon, R., Wisedopas, N., Sumdin, S., Ponuthai, Y., Wiangngoen, S., Kullavanijaya, P., et al. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.440 · Cited by 87
Colorectal cancer screening in Lynch syndrome: Indication, techniques and future perspectives
Perrod, G., Rahmi, G., & Cellier, C. (2021) · Digestive Endoscopy · doi:10.1111/den.13702 · Cited by 28
Metadata
- Authors
- Heresbach, D., Barrioz, T., Lapalus, M., Coumaros, D., Bauret, P., Potier, P., Sautereau, D., Boustière, C., Grimaud, J., Barthélémy, C., Sée, J., Serraj, I., D’Halluin, P., Branger, B., & Ponchon, T.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2008-04-04
- Volume
- 40
- Issue
- 04
- Pages
- 284-290
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2054367831
- Cited by
- 512
- References
- 0
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.