Glucose Clamping Using the Biostator GCIIS
The DOI matches its Crossref record.
Abstract
The Biostator GCIIS was used to clamp circulating glucose at hypoglycemic (42 +/- 1 mg/dl), euglycemic (86 +/- 2 mg/dl), and hyperglycemic (142 +/- 1 mg/dl) levels in normal subjects during a concomitant infusion of insulin (0.1 U/kg/h). Because of limitations in maximal glucose infusion (1 g/min) from the Biostator, a supplementary infusion of glucose was required to accomplish euglycemic and hyperglycemic clamps. The coefficients of variation of blood glucose were 7.06 +/- 1.3%, 5.9 +/- 0.5%, and 6.1 +/- 0.9 for 120 minutes of hypoglycemic, euglycemic, and hyperglycemic clamps, respectively. Despite the occasional interruption of blood flow in the double-lumen catheter and the occasional poor correlation between Biostator and reference glucose method, satisfactory glucose clamps could be maintained for 2 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gutniak, M., Ørkov, C., Holst, J. J., Ahrén, B., & Efendić, S. (1992) · New England Journal of Medicine · doi:10.1056/nejm199205143262003 · Cited by 868
Bolli, G. B., & Gerich, J. E. (1984) · New England Journal of Medicine · doi:10.1056/nejm198403223101203 · Cited by 235
Insulin resistance after abdominal surgery
Thorell, A., Efendic, S., Gutniak, M., Häggmark, T., & Ljungqvist, O. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810120 · Cited by 206
Effect of 8 hours of hyperinsulinaemia on haemostatic parameters in healthy man
Mauricio-Leguizamo, G., Heinemann, L., Scharf, R. E., & Berger, M. (1989) · Diabetologia · doi:10.1007/bf00285335 · Cited by 5
Metadata
- Authors
- Verdonk, C., Rizza, R., Westland, R., Nelson, R., Gerich, J., & Service, F.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 1980-04
- Volume
- 12
- Issue
- 04
- Pages
- 133-135
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W1995226608
- Cited by
- 44
- References
- 0
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.