Prediction of Lactate Threshold and Fixed Blood Lactate Concentrations from 3200-m Running Performance in Male Runners
The DOI matches its Crossref record.
Abstract
To determine the effectiveness of a 3200-m time trial for predicting V̇O 2 and running velocity at lactate threshold (LT), fixed blood lactate concentrations of 2.0, 2.5, and 4.0 mM, and peak, 42 male runners (X̄ age = 31.1 ± 8.3 years; X̄ ht = 176.8±6.6 cm; X̄ wt = 70.4 ± 10.0 kg) completed a V̇O 2 peak/LT test and a 3200-m time trial. The continuous treadmill protocol started at 0% grade 150 m/min and increased 10 m/min every 3 min until exhaustion. Velocity at LT, 2.0, 2.5, and 4.0 mM was determined from individual velocity blood lactate relationships, and V̇O 2 values were determined from individual plots ov V̇O 2 vs velocity. V̇O 2 peak and velocity peak were chosen as the highest values observed. Oxygen uptake at LT, 2.0, 2.5, 4.0 mM, and peak was 52.51, 56.61, 58.31, 61.70, and 64.21 ml/kg·min -1 , respectively, while the velocities associated with LT, 2.0, 2.5, 4.0 mM, and peak were 235.5, 251.5, 259.8, 273.5, and 285.5 m/min, respectively. During the 3200-m time trial (X̄ time = 11.28±0.96 min), 400-m split times and cumulative times were recorded. Twenty-nine subjects were randomly assigned to a validation sample and the remaining subjects were used for cross-validation purposes. Regression analysis revealed that a 3200-m time trial was a good predictor of both V̇O 2 (ml/kg·min -1 ) and velocity (m/min) at LT, 2.0, 2.5, 4.0 mM, and peak. In the validation sample correlation coefficients between 3200-m time and velocity at LT, 2.0, 2.5, 4.0 mM, and peak were r =0.85, 0.85, 0.86, 0.88, and 0.87, respectively, and the standard error of estimate ranged from ±11.1 m/min (3.9% for velocity max) to ±14.5 m/min (6.2% for velocity LT). For V̇O 2 (ml/kg· min -1 ) correlation coefficients ranged from r =0.73 (3200-m time vs V̇O 2 peak) to r =0.79 (3200-m time vs V̇O 2 4.0 mM) with standard errors of estimate ranging from ±6.7% (V̇O 2 4.0 mM) to ±8.3% (V̇O 2 LT). In the cross-validation sample correlation coefficients between actual and predicted velocities ranged from r =0.88 (velocity 2.0 mM) to r =0.97 (velocity peak) while correlation coefficients between actual and predicted V̇O 2 values ranged from r =0.61 (V̇O 2 LT) to r =0.81 (V̇O 2 2.5 mM). Mean differences between actual and predicted values in the cross-validation group were not significantly different for any variable. It was concluded that in male runners performance on a 3200-m time trial accurately predicts V̇O 2 and velocity at LT, 2.0, 2.5, 4.0 mM, and peak. The present findings have applicability for exercise prescription and running performance in male runners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Test of the Classic Model for Predicting Endurance Running Performance
MCLAUGHLIN, J. E., HOWLEY, E. T., BASSETT, D. R., THOMPSON, D. L., & FITZHUGH, E. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c0669d · Cited by 215
Mayorga-Vega, D., Bocanegra-Parrilla, R., Ornelas, M., & Viciana, J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151671 · Cited by 163
Sendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists
Driller, M., Borges, N., & Plews, D. (2016) · Sports Engineering · doi:10.1007/s12283-016-0198-6 · Cited by 15
Metadata
- Authors
- Weltman, A., Snead, D., Seip, R., Schurrer, R., Levine, S., Rutt, R., Reilly, T., Weltman, J., & Rogol, A.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1987-12
- Volume
- 08
- Issue
- 06
- Pages
- 401-406
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2057993801
- Cited by
- 42
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.