Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The second threshold was determined using the blood lactate concentration and muscle oxygenation in different sports such as cycling16,17,46–48, running44,45,49 and rowing26.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [47]
In the citing paper
“The articles included in this systematic review use different methods for determining thresholds: BSX Insight (20%, N = 3)45,47,49, double linear regression (46%, N = 7)16,26,39,41–44, visual method17,25,40, Dmax or modified Dmax46 and applications of devices Humon Beta48.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [47]
In the citing paper
“However, some studies explored other regions during cycling which could affect the determination of the threshold17,47, although the rectus femoris is also a power output producer in this area where there could be a higher proportion of adipose tissue52 or because its neuromuscular activation is not affected by the increase in workload during the test (e.g., gastrocnemius)53.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [47]
In the citing paper
“However, Batterson et al.44 showed a higher mean bias for MOT and LT1 (1.1–1.2 km·h−1), and Driller et al.47 also demonstrated how the method of determination could affect the bias, with the lowest being for the Dmax method (17 W) and the highest for the OBLA method (37 W).”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [47]
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Physiological and biomechanical factors associated with elite endurance cycling performance
COYLE, E. F., FELTNER, M. E., KAUTZ, S. A., HAMILTON, M. T., MONTAIN, S. J., BAYLOR, A. M., ABRAHAM, L. D., & PETREK, G. W. (1991) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199101000-00015 · Cited by 551
Determinants of endurance in well-trained cyclists
Coyle, E. F., Coggan, A. R., Hopper, M. K., & Walters, T. J. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2622 · Cited by 438
Seiler, S., & Tønnessen, E. (2009) · Cited by 379
Evaluation of the Lactate Pro blood lactate analyser
Pyne, D. B., Boston, T., Martin, D. T., & Logan, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050659 · Cited by 313
Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
Tanner, R. K., Fuller, K. L., & Ross, M. L. R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1379-9 · Cited by 274
The relationship between plasma lactate parameters, Wpeak and 1-h cycling performance in women
BISHOP, D., JENKINS, D. G., & MACKINNON, L. T. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199808000-00014 · Cited by 263
Software for calculating blood lactate endurance markers
Newell, J., Higgins, D., Madden, N., Cruickshank, J., Einbeck, J., McMillan, K., & McDonald, R. (2007) · Journal of Sports Sciences · doi:10.1080/02640410601128922 · Cited by 156
Cited by
The Importance of ‘Durability’ in the Physiological Profiling of Endurance Athletes
Maunder, E., Seiler, S., Mildenhall, M. J., Kilding, A. E., & Plews, D. J. (2021) · Sports Medicine · doi:10.1007/s40279-021-01459-0 · Cited by 205
Self-citationDose-Response Matters! - A Perspective on the Exercise Prescription in Exercise-Cognition Research
Herold, F., Müller, P., Gronwald, T., & Müller, N. G. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02338 · Cited by 196
Can Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 143
Perrey, S. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.864825 · Cited by 53
Sendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
Metadata
- Authors
- Driller, M., Borges, N., & Plews, D.
- Affiliations
- University of Waikato (NZ)
- Central Queensland University (AU)
- Corresponding author
- Driller, Matthew
- Venue
- Sports Engineering
- Published
- 2016-03-02
- Volume
- 19
- Issue
- 4
- Pages
- 229-235
- ISSN
- 1369-7072 (ISSN-L)
- 1460-2687
- OpenAlex
- W2293132568
- Cited by
- 15
- References
- 28
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 3 · 2019: 2 · 2018: 1 · 2016: 1
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sports Engineering (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- lactate threshold, near-infrared spectroscopy, muscle oxygenation, cyclists, incremental cycling test, blood lactate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists. https://app.cochat.ai/papers/10.1007/s12283-016-0198-6
- The paper
- Driller, M., Borges, N., & Plews, D. (2016). Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists. Sports Engineering. https://doi.org/10.1007/s12283-016-0198-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.