The DOI matches its Crossref record.
Frameless Neuronavigation in Modern Neurosurgery
Abstract
A fundamental effort in neurosurgery is to reduce surgical trauma. Microneurosurgical technique combined with precise localization of lesions, can minimize the invasiveness of neurosurgical procedures. This report summarizes the utility of frameless neuronavigator systems and examines their value in reducing operative invasiveness. The basic principle of neuronavigation is the virtual linkage between digitized neuroradiological data and real anatomical structures, allowing an excellent three-dimensional orientation by real-time graphic-anatomic interaction. As frameless graphic interactive neuronavigation is developed further, these devices should become an important component of the modern microneurosurgical armamentarium and reduce surgical morbidity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Imaging-guided surgical systems can be used to avoid major blood vessels and reduce blood extravasation (Spetzger et al., 1995), optimizing the implantation procedure.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Spetzger et al., 1995
Citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Imaging-guided surgical systems can be used to avoid major blood vessels and reduce blood extravasation (Spetzger et al., 1995), optimizing the implantation procedure.”
MethodPostimaging brain distortion: magnitude, correlates, and impact on neuronavigation
Dorward, N., Alberti, O., Velani, B., Gerritsen, F. A., Harkness, W. F. J., Kitchen, N. D., & Thomas, D. G. T. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.88.4.0656 · Cited by 289
“6 (SD 1) pathological group (%) I 20 (21) 13 (27) II 27 (29) 18 (38) III 25 (27) 11 (23) IV 21 (23) 6 (12)”
Brain Lab VectorVision Neuronavigation System: Technology and Clinical Experiences in 131 Cases
Gumprecht, H., Widenka, D. C., & Lumenta, C. B. (1999) · Neurosurgery · doi:10.1097/00006123-199901000-00056 · Cited by 269
Image-to-patient registration techniques in head surgery
Eggers, G., Mühling, J., & Marmulla, R. (2006) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2006.09.015 · Cited by 215
Reinges, M. H. T., Nguyen, H.-H., Krings, T., et al. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-003-0204-1 · Cited by 202
“The main causative factors of this so-called brain shift were actually identified as gravity, brain swelling, loss of CSF, and tumour debulking with re-expansion of the formerly compressed brain [3, 7, 8, 10, 13, 16, 19, 22, 24, 26, 29, 30, 34, 35, 38, 43, 44, 47, 52].”
BackgroundSelf-citationComputer-aided navigation in neurosurgery
Grunert, P., Darabi, K., Espinosa, J., et al. (2003) · Neurosurgical Review · doi:10.1007/s10143-003-0262-0 · Cited by 192
Boroojerdi, B., Foltys, H., Krings, T., Spetzger, U., Thron, A. K., & Töpper, R. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00027-3 · Cited by 181
Self-citationAccuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies
Dorward, N., Alberti, O., Palmer, J. D., et al. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.1.0160 · Cited by 167
Computer-aided navigation in neurosurgery
Hellwig, D. (2003) · Neurosurgical Review · doi:10.1007/s10143-003-0264-y · Cited by 144
Decreased sensory cortical excitability after 1 Hz rTMS over the ipsilateral primary motor cortex
Enomoto, H., Ugawa, Y., Hanajima, R., Yuasa, K., Mochizuki, H., Terao, Y., Shiio, Y., Furubayashi, T., Iwata, N., & Kanazawa, I. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00667-8 · Cited by 138
Belykh, E. G., Martirosyan, N. L., Yağmurlu, K., Miller, E. J., Eschbacher, J. M., Izadyyazdanabadi, M., Bardonova, L., Byvaltsev, V. A., Nakaji, P., & Preul, M. C. (2016) · Frontiers in Surgery · doi:10.3389/fsurg.2016.00055 · Cited by 143
Wu, S.-Y., Aurup, C., Sánchez, C. S., Grondin, J., Zheng, W., Kamimura, H. A. S., Ferrera, V. P., & Konofagou, E. E. (2018) · Scientific Reports · doi:10.1038/s41598-018-25904-9 · Cited by 136
Rubino, G. J., Farahani, K., McGill, D. R., et al. (2000) · Neurosurgery · doi:10.1097/00006123-200003000-00023 · Cited by 103
Glioma surgery using a multimodal navigation system with integrated metabolic images
Tanaka, Y., Nariai, T., Momose, T., et al. (2008) · Journal of neurosurgery · doi:10.3171/2008.4.17569 · Cited by 93
Introducing navigated transcranial magnetic stimulation as a refined brain mapping methodology
Krings, T., Chiappa, K. H., Foltys, H., et al. (2001) · Neurosurgical Review · doi:10.1007/s101430100151 · Cited by 93
“The inherent localization error of the stereotactic system mainly depends on calibration accuracy and ranges typically between 2 mm and 8 mm [ 51 ].”
BackgroundMethodIntraoperative Image Guidance in Neurosurgery: Development, Current Indications, and Future Trends
Schulz, C., Waldeck, S. S., & Mauer, U. M. (2012) · Radiology Research and Practice · doi:10.1155/2012/197364 · Cited by 88
“Image guidance in neurosurgery is today a frequently used tool for operations of many brain lesions, mostly for small and deeply subcortical located brain tumors or cavernomas [1].”
BackgroundOhue, S., Kumon, Y., Nagato, S., et al. (2010) · Neurologia medico-chirurgica · doi:10.2176/nmc.50.291 · Cited by 75
Motekallemi, A., Jeltema, H., Metzemaekers, J. D. M., van Dam, G. M., Crane, L. M. A., & Groen, R. J. M. (2015) · Neurosurgical Review · doi:10.1007/s10143-015-0615-5 · Cited by 71
“real-time feedback [8–14].”
Metabolic and electrophysiological validation of functional MRI
Krings, T. (2001) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.71.6.762 · Cited by 70
“19 From those two sets of coordinates a matrix transformation was calculated which allowed the computer workstation to display the coordinates of the arm tip on the three dimensional MRI in real time.”
MethodNavigation concepts for MR image‐guided interventions
Moche, M., Trampel, R., Kahn, T., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21262 · Cited by 67
“Therefore, framebased or dynamic navigation on the basis of preoperative image data in a conventional OR are well established for neurosurgical procedures (51).”
BackgroundRohde, V., Reinges, M. H. T., Krombach, G. A., et al. (1998) · British Journal of Neurosurgery · doi:10.1080/02688699844385 · Cited by 67
Self-citationDay Surgery Awake Craniotomy for Removing Brain Tumours: Technical Note Describing a Simple Protocol
Carrabba, G. G., Venkatraghavan, L., & Bernstein, M. (2008) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2008-1073132 · Cited by 64
Mochizuki, H., Furubayashi, T., Hanajima, R., Terao, Y., Mizuno, Y., Okabe, S., & Ugawa, Y. (2007) · Experimental Brain Research · doi:10.1007/s00221-007-0884-5 · Cited by 62
“In two of the subjects, that position was conWrmed to be over the primary motor cortex by the neuronavigation system (Spetzger et al. 1995; Boroojerdi et al. 1999).”
BackgroundMochizuki, H., Ugawa, Y., Terao, Y., & Sakai, K. L. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0149-0 · Cited by 62
“In two of them, that position was confirmed to be over the primary motor cortex by the neuronavigation system (Spetzger et al. 1995; Boroojerdi et al. 1999).”
BackgroundKrings, T., Reul, J., Spetzger, U., Klusmann, A., Roessler, F. C., Gilsbach, J. M., & Thron, A. K. (1998) · Acta Neurochirurgica · doi:10.1007/s007010050088 · Cited by 56
“The combination of anatomical and physiological information makes fMRI an ideal tool for presurgical localisation, surgical planning and intracranial navigation [6, 13, 14, 22, 26, 34].”
BackgroundSelf-citationAugmented reality navigation for cranial biopsy and external ventricular drain insertion
Skyrman, S., Lai, M., Edström, E., Burström, G. L., Förander, P., Homan, R., Kor, F., Holthuizen, R., Hendriks, B. H. W., Persson, O., et al. (2021) · Neurosurgical FOCUS · doi:10.3171/2021.5.focus20813 · Cited by 48
The past, present and future of minimally invasive spine surgery: A review and speculative outlook
Spetzger, U., von Schilling, A., Winkler, G., et al. (2013) · Minimally Invasive Therapy & Allied Technologies · doi:10.3109/13645706.2013.821414 · Cited by 48
“All robot approaches are based on computerassisted surgery technologies (68).”
Self-citationNeuroendoscopy combined with frameless neuronavigation
Gumprecht, H. A. T. H. (2000) · British Journal of Neurosurgery · doi:10.1080/02688690050004552 · Cited by 48
Roethe, A. L., Rösler, J., Misch, M., et al. (2021) · Acta Neurochirurgica · doi:10.1007/s00701-021-05045-1 · Cited by 43
“Despite being the favored view in our study, the AR navigation view does not reveal context information outside the currently displayed sectional planes; it requires further interaction, such as change of focal plane, to provide visualized information above and below the actual resection plane, which can be crucial in…”
BackgroundNeuronavigation: principles, clinical applications and potential pitfalls.
Khoshnevisan, A., & Allahabadi, N. S. (2012) · PubMed · Cited by 41
Woydt, M., Krone, A., Soerensen, N., et al. (2001) · British Journal of Neurosurgery · doi:10.1080/02688690120097714 · Cited by 41
Haemmerli, J., Davidovic, A., Meling, T. R., et al. (2021) · Neurosurgical FOCUS · doi:10.3171/2020.10.focus20789 · Cited by 40
Stereoelectroencephalography in children: a review
Ho, A. L., Feng, A. Y., Kim, L. H., et al. (2018) · Neurosurgical FOCUS · doi:10.3171/2018.6.focus18226 · Cited by 36
Zhou, H., Miller, D., Schulte, D. M., et al. (2008) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2008.09.025 · Cited by 36
Woydt, M., Horowski, A., Krone, A., et al. (1999) · Acta Neurochirurgica · doi:10.1007/s007010050278 · Cited by 34
“such as open/intra-operative MRI [9, 63, 69], Neuronavigation systems [21, 47, 50, 65, 70], stereotactic”
BackgroundNavigiert-kontrollierte Kochleostomie
Schipper, J. H., Klenzner, T., Aschendorff, A., et al. (2004) · HNO · doi:10.1007/s00106-004-1057-5 · Cited by 32
“Zentrales Problem ist die noch ungenügende Genauigkeit im Bereich der Laterobasis [18].”
BackgroundVeres, R., Bagó, A. G., & Fedorcsák, I. (2001) · Spine · doi:10.1097/00007632-200106150-00024 · Cited by 31
“For posterior approach the use of anatomic landmarks combined with surface mapping and one-by-one registration of the target vertebrae can be an acceptable procedure, but the small registration surface and the great distance between the registration and the target area can significantly diminish the accuracy.(5,7) For…”
MethodAkdemir, H., Öktem, S., Menkü, A., et al. (2007) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2007-985376 · Cited by 27
Practicability of magnetoencephalography-guided neuronavigation
Firsching, R. P., Bondar, I., Heinze, H. –., et al. (2002) · Neurosurgical Review · doi:10.1007/s101430100161 · Cited by 25
Woerdeman, P. A., Willems, P. W. A., Noordmans, H. J., et al. (2008) · Journal of neurosurgery · doi:10.3171/2008.3.17431 · Cited by 23
Krombach, G. A., Spetzger, U., Rohde, V., et al. (1998) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(1998)3:2 · Cited by 23
Self-citationDevelopment of an Endoscopic Navigation System Based on Digital Image Processing
Scholz, M., Konen, W., Tombrock, S., et al. (1998) · Computer Aided Surgery · doi:10.3109/10929089809149841 · Cited by 21
Chen, T.-Y., Lin, K.-L., & Ho, H.-H. (2004) · Spine · doi:10.1097/00007632-200405010-00009 · Cited by 21
Reinges, M. H. T., Krings, T., Rohde, V., et al. (2004) · Cited by 20
Self-citationState of the art of fluorescence guided techniques in neurosurgery
Rocca, G. L., Pepa, G. M. D., Menna, G., et al. (2020) · Journal of Neurosurgical Sciences · doi:10.23736/s0390-5616.19.04854-9 · Cited by 19
Development of an endoscopic navigation system based on digital image processing
Scholz, M., Konen, W., Tombrock, S., et al. (1998) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(1998)3:3 · Cited by 19
Sensor-based neuronavigation: Evaluation of a large continuous patient population
Kuehn, B., Mularski, S., Schoenherr, S., et al. (2008) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2008.06.017 · Cited by 18
Neuronavigation. Principles. Surgical technique.
Ivanov, M., & Ciurea, A. V. (2010) · PubMed · Cited by 17
Virtual image navigation: a new method to control intraoperative bleeding in neuroendoscopic surgery
Scholz, M., Fricke, B., Tombrock, S., et al. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.2.0342 · Cited by 17
Hayashi, N., Kurimoto, M., Hirashima, Y., et al. (2001) · Neurologia medico-chirurgica · doi:10.2176/nmc.41.335 · Cited by 17
Current and Emerging Systems for Focused Ultrasound-Mediated Blood–Brain Barrier Opening
Hughes, A., Khan, D. S., & Alkins, R. D. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.02.017 · Cited by 16
Giamouriadis, A., Perera, D., Safdar, A., et al. (2019) · Acta Neurochirurgica · doi:10.1007/s00701-019-04093-y · Cited by 16
Krombach, G. A., Spetzger, U., Rohde, V., et al. (1998) · Computer Aided Surgery · doi:10.3109/10929089809148131 · Cited by 16
Self-citationImage-guided Procedures in Brain Biopsy
Fujita, K., Yanaka, K., Meguro, K., et al. (1999) · Neurologia medico-chirurgica · doi:10.2176/nmc.39.502 · Cited by 16
Reliability of neuronavigation-assisted trans-sphenoidal tumor resections
y Nievas, M. N. C., & Höllerhage, H.-G. (2007) · Neurological Research · doi:10.1179/016164107x164184 · Cited by 15
Spinal cord bioelectronic interfaces: opportunities in neural recording and clinical challenges
Jiang, L., Woodington, B. J., Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac605f · Cited by 14
Reinges, M. H. T., Krings, T., Nguyen, H.-H., et al. (2000) · Acta Neurochirurgica · doi:10.1007/s007010070009 · Cited by 13
Self-citationHirose, M., Mochizuki, H., Groiss, S. J., et al. (2011) · Experimental Brain Research · doi:10.1007/s00221-011-2855-0 · Cited by 12
“In two of the subjects, that position was conWrmed to be over the primary motor cortex by the neuronavigation system (Spetzger et al. 1995; Boroojerdi et al. 1999).”
BackgroundDavidovic, A., Chavaz, L., Meling, T. R., et al. (2021) · Neurosurgical FOCUS · doi:10.3171/2021.5.focus21202 · Cited by 11
Results and Complications from the Use of a Frameless Stereotactic Microscopic Navigator System
Fountas, K. N., Kapsalaki, E., Smisson, H. F., et al. (1998) · Stereotactic and Functional Neurosurgery · doi:10.1159/000029650 · Cited by 11
Vychopen, M., Wach, J., Borger, V., et al. (2022) · Brain Sciences · doi:10.3390/brainsci12091178 · Cited by 10
THE EFFECT OF REPETITIVE MANUAL FIDUCIAL LOCALIZATION ON TARGET LOCALIZATION IN IMAGE SPACE
Woerdeman, P. A., Willems, P. W. A., Noordmans, H. J., et al. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000249231.74741.c3 · Cited by 10
“In neurosurgical practices, image-guided surgery is often considered a welcome addition to the armamentarium of the surgeon (2, 7).”
BackgroundReinges, M. H. T., Krings, T., Nguyen, H.-H., et al. (2000) · Computer Aided Surgery · doi:10.1002/igs.1004 · Cited by 9
Self-citationfMRI und direkte elektrische kortikale Stimulation
Krings, T., Krombach, G. A., Reul, J., Spetzger, U., Roessler, F. C., Foltys, H., Gilsbach, J. M., & Thron, A. K. (1998) · Clinical Neuroradiology · doi:10.1007/bf03043439 · Cited by 7
Self-citationPotential of sonobiopsy as a novel diagnosis tool for brain cancer
Li, Y., Fu, K., Li, L., Li, Q., & Zhou, X. (2024) · Molecular Therapy Oncology · doi:10.1016/j.omton.2024.200840 · Cited by 7
“94 Lu Xu et al. developed a neuronavigation-guided sonobiospy device and characterized its targeting accuracy in vivo , in vitro , and in silico .”
BackgroundRemotely-controlled approach for stereotactic neurobiopsy
Liu, H., Hall, W. A., & Truwit, C. L. (2002) · Computer Aided Surgery · doi:10.1002/igs.10047 · Cited by 7
Remotely-Controlled Approach for Stereotactic Neurobiopsy
Liu, H., Hall, W. A., & Truwit, C. L. (2002) · Computer Aided Surgery · doi:10.3109/10929080209146032 · Cited by 7
Park, J., Han, J. H., Kim, C., et al. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0773-8 · Cited by 6
“A frame-based stereotactic system is the most common system used, although there are several less invasive nonframe-based systems for reducing pain [6, 9, 21, 23 ].”
MethodSchulz, C., Woerner, U., & Luelsdorf, P. (2007) · Surgical Neurology · doi:10.1016/j.surneu.2006.11.058 · Cited by 6
Clinical Experiences in Neuronavigation
Chen, H.-J. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000066711 · Cited by 6
Reinges, M. H. T., Krings, T., Nguyen, H.-H., et al. (2000) · Computer Aided Surgery · doi:10.3109/10929080009148902 · Cited by 6
Self-citationFrameless stereotactic for deep brain stimulation placement: operative technique.
Srikijvilaikul, T., & Bhidayasiri, R. (2008) · PubMed · Cited by 4
A dynamic and extensible workflow-oriented software framework for image-guided therapy
Samset, E., Hans, A., DiMaio, S., et al. (2007) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-007-0131-3 · Cited by 4
“Applications such as neuronavigation [1], CT-guided orthopedic interventions [2], virtual endoscopy [3] and many others are good examples of clinical applications in which the computer-aided navigation technology plays a central role.”
BackgroundImage-Guided Surgery for Meningiomas
Thomas, T., & Barnett, G. H. (2008) · Springer eBooks · doi:10.1007/978-1-84628-784-8_22 · Cited by 4
The SIGN: A dynamic and extensible software framework for Image-Guided Therapy
Samset, E., Hans, A., von Spiczak, J., et al. (2006) · The Insight Journal · doi:10.54294/2ftlt1 · Cited by 4
Neuronavigation of Cerebral Lesions
Spetzger, U. (1998) · Medical radiology · doi:10.1007/978-3-642-60272-6_19 · Cited by 4
Self-citationFluorescence in neurosurgery: its therapeutic and diagnostic significance – a comprehensive review
Rauf, S. A., Ahmed, R., Hussain, T., et al. (2024) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000002218 · Cited by 3
“This enables them to assess the extent of tumor resection, identify residual tumor tissue, and make necessary real-time adjustments to the surgical approach, ensuring optimal surgical outcomes [8] .”
BackgroundDevelopment of a brain simulator for intracranial targeting: Technical note
Carolus, A. E., Hesse, M., Rudak, B., et al. (2018) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2018.10.060 · Cited by 3
DiPatri, A. J., Pham, M. H., & Muro, K. (2009) · Cancer treatment and research · doi:10.1007/b109924_2 · Cited by 3
A Comparative Statistical Error Analysis of Neuronavigation Systems in a Clinical Setting
Abbasi, H. R., Hariri, S., Martin, D. P., et al. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_15 · Cited by 2
Neuronavigation and epilepsy surgery
Glaser, M. B., Werhahn, K. J., Grunert, P., et al. (2010) · Health · doi:10.4236/health.2010.27114 · Cited by 2
“Nowadays, frameless neuronavigation is an accepted tool in contemporary microneurosurgery [12-15].”
BackgroundLumenta, C. B., Gumprecht, H., & Krammer, M. (2009) · Neurosurgery · doi:10.1007/978-3-540-79565-0_36 · Cited by 2
Training Models for Skull-Base and Vascular Micro-Neurosurgery
Spetzger, U., Etingold, J., & von Schilling, A. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.101924 · Cited by 2
Self-citationSo, J., Lee, H., Jeong, J., et al. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.979290 · Cited by 2
“Neuronavigation (NN) and the endoscopic approach have been developed to increase the accuracy and safety of surgeries (10, 14, 15).”
BackgroundMethodExperiences with the Neuronavigation System EasyGuide Neuro
Spetzger, U., Reinges, M. H. T., Krombach, G. A., et al. (1998) · Springer eBooks · doi:10.1007/978-3-642-58731-3_32 · Cited by 2
Self-citationBeurteilung des präoperativen Brain shift mit Hilfe des Neuronavigationssystems EasyGuide Neuro
Reinges, M. H. T., Nguyen, H.-H., Spetzger, U., et al. (1998) · Informatik aktuell · doi:10.1007/978-3-642-58775-7_23 · Cited by 2
Self-citationHaberland, N., Ebmeier, K., & Kalff, R.-L. (1999) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-60017-3_29 · Cited by 2
Türkkan, A., & Bekâr, A. (2024) · Uludağ Üniversitesi Tıp Fakültesi Dergisi · doi:10.32708/uutfd.1519795 · Cited by 1
Scholz, M., Hardenack, M., Konen, W., et al. (1999) · Minimally Invasive Therapy & Allied Technologies · doi:10.3109/13645709909153180 · Cited by 1
Initial Trials of a Neurosurgical Navigation System
Nishizaki, T., YOSHIKAWA, K., Ideguchi, M., et al. (1998) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.7.177 · Cited by 1
A Brief Explanation on Surgical Approaches for Treatment of Different Brain Tumors
Broggi, M. A., Zattra, C. M., Restelli, F., Acerbi, F., Seveso, M., Devigili, G., Schiariti, M. P., Vetrano, I. G., Ferroli, P., & Broggi, G. (2023) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-23705-8_27 · Cited by 1
Calvarial Biopsy Using Augmented Reality Technology: A Case Report and Technical Note
Sharma, N., Shanahan, R. M., Bhatia, S., et al. (2025) · Asian Journal of Neurosurgery · doi:10.1055/s-0045-1809048 · Cited by 1
“9 These systems havetraditionallyallowed surgeons totrack instrumentation relative to a patient ’ s anatomy based on co-registration, with a dynamic reference frame and preoperative imaging.”
Development of a pin-less reference head frame: An experimental setup and preliminary experiences
Carolus, A. E., Fürst, J., Weihe, S., et al. (2018) · Interdisciplinary Neurosurgery · doi:10.1016/j.inat.2018.03.007 · Cited by 1
Rechnerunterstütztes Operieren in der Neurotraumatologie
Haberland, N., Meinig, H., Eymer-Salim, D., et al. (2001) · Trauma und Berufskrankheit · doi:10.1007/s10039-001-0498-2 · Cited by 1
“Die Navigation gehört heute bei ausgewählten neurochirurgischen intrakranialen Eingriffen bereits zum Standard, wobei die Quantität dieser Operationen weiter zunimmt [17, 18, 22, 31, 35, 53, 54].”
BackgroundHoelper, B. M., Soldner, F., & Behr, R. (2004) · Springer eBooks · doi:10.1007/978-3-7091-0622-8_3 · Cited by 1
Conception et caractérisation d’un outil de neuronavigation pour le rat
Boukhal, K. Z. (2011)
Kühn, B. (2009) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-5843
Frameless image-guided neurosurgery in motion
Woerdeman, P. A. (2008) · Utrecht University Repository (Utrecht University)
Usefulness of Imaging Fusion for Therapeutic Planning in Skull Base Lesions
Puglielli, E., Galzio, R. J., Ricci, A., et al. (2003) · Rivista di Neuroradiologia · doi:10.1177/197140090301600210
Maier, W., Schipper, J. H., Arapakis, I., et al. (2004) · Springer eBooks · doi:10.1007/978-3-7091-0622-8_9
“Die rasante Entwicklung auf dem Gebiet der Informationstechnologie und Bildgebung eroffnet dem Schadelbasischirurgen he ute Moglichkeiten [4, 11], die vor weni-”
BackgroundSelf-citation
Metadata
- Authors
- Spetzger, U., Laborde, G., & Gilsbach, J.
- Affiliations
- RWTH Aachen University (DE)
- ORCID
- Spetzger, U.
- Venue
- min - Minimally Invasive Neurosurgery
- Publisher
- Georg Thieme Verlag KG
- Published
- 1995-12
- Volume
- 38
- Issue
- 04
- Pages
- 163-166
- ISSN
- 0946-7211 (ISSN-L)
- 1439-2291
- OpenAlex
- W1979092172
- Cited by
- 107
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 5 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 2
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- min - Minimally Invasive Neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Health Sciences › Medicine › Surgery › History of Medical Practice
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- frameless neuronavigation, neuronavigation, microneurosurgery, lesion localization, surgical morbidity
- MeSH terms
- Humans, Image Processing, Computer-Assisted, Neurosurgery, Stereotaxic Techniques, Minimally Invasive Surgical Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review