Abstract
A fundamental effort in neurosurgery is to reduce surgical trauma. Microneurosurgical technique combined with precise localization of lesions, can minimize the invasiveness of neurosurgical procedures. This report summarizes the utility of frameless neuronavigator systems and examines their value in reducing operative invasiveness. The basic principle of neuronavigation is the virtual linkage between digitized neuroradiological data and real anatomical structures, allowing an excellent three-dimensional orientation by real-time graphic-anatomic interaction. As frameless graphic interactive neuronavigation is developed further, these devices should become an important component of the modern microneurosurgical armamentarium and reduce surgical morbidity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Imaging-guided surgical systems can be used to avoid major blood vessels and reduce blood extravasation (Spetzger et al., 1995), optimizing the implantation procedure.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Spetzger et al., 1995
Citations
Cited by
Sorted by citations
Items 101–110 of 110
Iannessi, F., Splendiani, A., Amicis, R. D., et al. (2003) · Rivista di Neuroradiologia · doi:10.1177/19714009030160s1113
Spetzger, U., Reinges, M. H. T., Struffert, T., et al. (2002) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.1998.724117
Self-citationTherapeutical Principles in the Treatment of Skull Base Pathologies
Spetzger, U., Bleif, M., & Becker, G. (2017) · Springer eBooks · doi:10.1007/978-3-319-64018-1_3
Self-citationChirurgische Therapieprinzipien bei Erkrankungen der Schädelbasis
Spetzger, U. (2017) · Springer eBooks · doi:10.1007/978-3-662-54672-7_3
Self-citationIntroducing stereotactic transcranial magnetic stimulation as a refined brain mapping methodology
Krings, T., Foltys, H., Butler, W. E., et al. (1998) · NeuroImage · doi:10.1016/s1053-8119(18)31520-9
Self-citationA Simple Method to Avoid Brain Shift during Neuronavigation: Technical Note
Raso, J. L. (2020) · Arquivos Brasileiros de Neurocirurgia Brazilian Neurosurgery · doi:10.1055/s-0040-1716560
Current Status of Augmented Reality in the Spine
Burström, G. L., Persson, O., Edström, E., et al. (2022) · Springer eBooks · doi:10.1007/978-981-19-0175-1_33
Utilización de la neuronavegación en procedimientos neuroquirúrgicos
Ferreira, M. M. D. V., Alcorta, S. C., Cervio, A., et al. (2007) · NeuroTarget · doi:10.47924/neurotarget2007377
Robotik. Grundlagen, Beispiele, Visionen
Christaller, T., Decker, M., Gilsbach, M. J., Hirzinger, G., Lauterbach, K. W., Schweighofer, E., Schweitzer, G., & Sturma, D. (2001) · Springer eBooks · doi:10.1007/978-3-642-56422-2_3
Spennato, P., Tengattini, F., Costanzo, M. D., et al. (2026) · Springer eBooks · doi:10.1007/978-3-032-18992-9_6
Metadata
- Authors
- Spetzger, U., Laborde, G., & Gilsbach, J.
- Affiliations
- RWTH Aachen University (DE)
- ORCID
- Spetzger, U.
- Venue
- min - Minimally Invasive Neurosurgery
- Publisher
- Georg Thieme Verlag KG
- Published
- 1995-12
- Volume
- 38
- Issue
- 04
- Pages
- 163-166
- ISSN
- 0946-7211 (ISSN-L)
- 1439-2291
- OpenAlex
- W1979092172
- Cited by
- 107
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 5 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 2
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- min - Minimally Invasive Neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Health Sciences › Medicine › Surgery › History of Medical Practice
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- frameless neuronavigation, neuronavigation, microneurosurgery, lesion localization, surgical morbidity
- MeSH terms
- Humans, Image Processing, Computer-Assisted, Neurosurgery, Stereotaxic Techniques, Minimally Invasive Surgical Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review