The DOI matches its Crossref record.
Volumetrie der Schilddrüsenlappen mittels Real-time-Sonographie* 1
Open accessAbstract
Thyroid volume as measured by real-time ultrasound in cadavers was compared with direct measurements obtained by submersion. Length X width X thickness of the thyroid lobe multiplied by factor pi/6, correspond to a rotation ellipsoid, while the best calculated volume of the lobe is obtained by multiplying with the optimised correction factor f = 0.479. The correctness of this calculation is, by definition, 100%; average error of the method is 16%. The measurements are easy to do and require no additional equipment for planimetry or calculations. Volumetric analysis of the thyroid gland is especially necessary in assessing results of treatment and for measuring dosage in connection with radioiodine therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zimmermann, M. B. (2009) · Endocrine Reviews · doi:10.1210/er.2009-0011 · Cited by 1,071
Cohort Profile: The Study of Health in Pomerania
Volzke, H., Alte, D., Schmidt, C. O., Radke, D., Lorbeer, R., Friedrich, N., Aumann, N., Lau, K., Piontek, M., Born, G., et al. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyp394 · Cited by 1,000
Very high prevalence of thyroid nodules detected by high frequency (13 MHz) ultrasound examination
Guth, S., Theune, U., Aberle, J., Galach, A., & Bamberger, C. M. (2009) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2009.02162.x · Cited by 978
Effect of Iodine Intake on Thyroid Diseases in China
Teng, W., Shan, Z., Teng, X., Guan, H., Li, Y., Teng, D., Jin, Y., Yu, X., Fan, C., Chong, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054022 · Cited by 742
Management of Simple Nodular Goiter: Current Status and Future Perspectives
Hegedüs, L., Bonnema, S. J., & Bennedbæk, F. N. (2003) · Endocrine Reviews · doi:10.1210/er.2002-0016 · Cited by 710
Metadata
- Authors
- Brunn, J., Block, U., Ruf, G., Bos, I., Kunze, W. P., & Scriba, P. C.
- Venue
- DMW - Deutsche Medizinische Wochenschrift
- Publisher
- Georg Thieme Verlag KG
- Published
- 2008-03-26
- Volume
- 106
- Issue
- 41
- Pages
- 1338-1340
- ISSN
- 0012-0472 (ISSN-L)
- 1439-4413
- OpenAlex
- W1971939771
- Cited by
- 643
- References
- 0
- FWCI
- 16.56
- Type
- journal article
- Language
- de
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetrie der Schilddrüsenlappen mittels Real-time-Sonographie* 1. https://app.cochat.ai/papers/10.1055/s-2008-1070506
- The paper
- Brunn, J., Block, U., Ruf, G., Bos, I., Kunze, W. P., & Scriba, P. C. (2008). Volumetrie der Schilddrüsenlappen mittels Real-time-Sonographie* 1. DMW - Deutsche Medizinische Wochenschrift. https://doi.org/10.1055/s-2008-1070506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.