Comparison of M22-based ELISA and Human-TSH-Receptor-based Luminescence Assay for the Measurement of Thyrotropin Receptor Antibodies in Patients with Thyroid Diseases

Liu, C., Hermsen, D., Domberg, J., Graeber, C., Hautzel, H., Duan, Y., Xu, K., Liu, C., Mao, X., Cupisti, K., Scherbaum, W., Schott, M. · 2008 · Hormone and Metabolic Research
Cited by 35

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Previously, a new procedure for measuring serum TSH receptor autoantibodies (TRAb) was reported in which the autoantibodies inhibit binding of a human monoclonal thyroid stimulating antibody M22 to TSHR-coated ELISA plate wells (TRAb ELISA). The aim of the present study was to evaluate the clinical performance of this assay in comparison to the second generation TRAb assay (TRAb LIA) based on the recombinant human TSH-receptor and chemiluminescence technology (TRAb LIA). Among the 158 patients, 84 patients suffered from Graves' disease (GD), 34 patients had Hashimoto's thyroiditis (HT), and 40 patients had euthyroid nodular thyroid disease (NTD) without signs of autoimmunity. TRAb measurements were performed according to the manufacturer's instructions. Out of 84 GD patients, 80 (95.2%) were TRAb positive as detected by the TRAb LIA. One GD patient had TRAb values within the grey zone (1.0-1.5 IU/l). All patients with HT and NTD were negative except in 6 (8.1%) cases whose TRAb values were within the grey zone. On the basis of the recommended cutoff value (TRAb 1.0 IU/l), the TRAb ELISA found 78 of 84 (92.9%) GD patients to be TRAb positive. None of the patients with HT, but two cases (5.0%) with NTD were TRAb positive. The diagnostic sensitivity of the TRAb LIA and TRAb ELISA assays was 95.2 and 92.9%, while the specificity was 100% and 97.3%, respectively. There was a close correlation (r=0.968, p<0.0001) between both assays in 84 patients with GD. Additionally, the between-run imprecision close to the cutoff limit was assessed. The calculated between-run coefficient of variation (CV) of the TRAb ELISA was 28.2% at the recommended cutoff value of 1.0 IU/l. Due to the evaluated imprecision data we propose a higher cutoff value correlating with a between-run CV of 20% (functional assay sensitivity). Our results indicate that due to a worse imprecision the TRAb ELISA has a slightly lower sensitivity and specificity compared to the TRAb LIA assay. These findings suggest that the M22 monoclonal antibody-based TRAb ELISA is not as reliable as other second generation TRAb assays in the diagnosis of Graves' diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2008-1077051

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 35

Metadata

Authors
Liu, C., Hermsen, D., Domberg, J., Graeber, C., Hautzel, H., Duan, Y., Xu, K., Liu, C., Mao, X., Cupisti, K., Scherbaum, W., & Schott, M.
Venue
Hormone and Metabolic Research
Published
2008-07
Volume
40
Issue
07
Pages
479-483
ISSN
  • 0018-5043 (ISSN-L)
  • 1439-4286
OpenAlex
W2327783775
Cited by
35
References
3
FWCI
3.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.