Determination of Standard (Basal) Metabolism of Patients by a Recording Apparatus
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BMRmeasurements using open circuit calorimetry show little difference due to type of equipment used 23-26 using a range of methods, notably Douglas Bag, Oxylog, HB metabolator, ventilated hood, canopy and whole body calorimeter, showed marginal difference in BMR between methods used (see Table 1).”
From Basal metabolic rate studies in humans: measurement and development of new equations (2005) · cites this paper as [24]
Citations
Cites
The Relative Value of Fat and Carbohydrate as Sources of Muscular Energy
Krogh, A., & Lindhard, J. (1920) · Biochemical Journal · doi:10.1042/bj0140290 · Cited by 411
Self-citationÜber das Minutenvolum des Herzens bei Ruhe und bei Muskelarbeit
Lindhard, J. (1915) · Pflüger's Archiv für die Gesamte Physiologie des Menschen und der Tiere · doi:10.1007/bf01681245 · Cited by 161
Über die Größe der Kohlensäureabgabe bei Verminderung des Kohlensäurepartiardruckes in den Alveolen1
Liljestrand, G. (1916) · Skandinavisches Archiv Für Physiologie · doi:10.1111/j.1748-1716.1916.tb00109.x · Cited by 11
Research works printed but not linked: 2
- Benedict P. G., 1918, Jour., 178, 567
- Aub, 1917, J. 0., and Du Bois, E. F. : Ibid., 19, 823
Cited by
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033
“To avoid this confusion, Krogh 5 coined the term ‘standard metabolism’.”
InfluentialThe Excitability of the Respiratory Centre daring Sleep and during Evipan Anaesthesia.
ØSTERGAARD, T. (1944) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1944.tb03047.x · Cited by 65
DETERMINATION OF BASAL RATE OF OXYGEN CONSUMPTION BY OPEN AND CLOSED-CIRCUIT METHODS
Fowler, W. S., Blackburn, C. M., & HELMHOLZ, H. F. (1957) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-17-6-786 · Cited by 31
Gedeon, A., Krill, P., Kristensen, J. D., & Gottlieb, I. (1992) · The Journal of Clinical Monitoring · doi:10.1007/bf01617908 · Cited by 21
“This part of the device for determining the oxygen uptake (Vo2) is a development of the classic Krogh apparatus [18] and has been previously described in more detail [19].”
MethodRossier, P., Bühlmann, A., & Wiesinger, K. (1958) · Springer eBooks · doi:10.1007/978-3-642-87856-5_4 · Cited by 17
Metadata
- Authors
- KROGH, A.
- Corresponding author
- KROGH, AUGUST
- ORCID
- KROGH, AUGUST
- Venue
- The Boston Medical and Surgical Journal
- Publisher
- Massachusetts Medical Society
- Published
- 1923-08-30
- Volume
- 189
- Issue
- 9
- Pages
- 313-317
- ISSN
- 0028-4793 (ISSN-L)
- 0096-6762
- 1533-4406
- OpenAlex
- W2330430568
- Cited by
- 28
- References
- 3
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- Topics
- Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Keywords
- basal metabolic rate, standard metabolic rate, metabolic measurement, recording equipment, metabolic monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Standard (Basal) Metabolism of Patients by a Recording Apparatus. https://app.cochat.ai/papers/10.1056/nejm192308301890904
- The paper
- KROGH, A. (1923). Determination of Standard (Basal) Metabolism of Patients by a Recording Apparatus. The Boston Medical and Surgical Journal. https://doi.org/10.1056/nejm192308301890904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.