The DOI matches its Crossref record.
Hypersensitivity Pneumonitis Due to Contamination of an Air Conditioner
Abstract
In four of 27 office workers, symptoms of intermittent chills, fever and dyspnea, or progressive dyspnea alone developed. Pulmonary-function studies indicated restrictive and diffusion defects, and x-ray examination demonstrated diffuse nodular infiltrates in all four patients. Examination of their environment revealed contamination of the air-conditioning system with a thermophilic actinomycete known to cause a hypersensitivity pneumonitis such as farmer's lung. Serum specimens of all patients contained high titers of rheumatoid factor and precipitating antibodies against the offending organism. Inhalation of the antigen by one of the ill workers during an asymptomatic period reproduced all clinical features of the disorder. Treatment with steroids and subsequent avoidance of exposure resulted in complete recovery. Hypersensitivity pneumonitis should be suspected in cases of interstitial pneumonitis, even in the absence of clear-cut contact with organic dusts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adverse Health Effects Among Adults Exposed to Home Dampness and Molds
Dales, R. E., Burnett, R., & Zwanenburg, H. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.3.505 · Cited by 295
Toyotome, T., Matsumoto, N., Itoh, M., & Yamada, K. (2022) · Medical Mycology Journal · doi:10.3314/mmj.22.002 · Cited by 4
Metadata
- Authors
- Banaszak, E. F., Thiede, W. H., & Fink, J. N.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1970-08-06
- Volume
- 283
- Issue
- 6
- Pages
- 271-276
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1963642851
- Cited by
- 315
- References
- 0
- FWCI
- 20.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypersensitivity Pneumonitis Due to Contamination of an Air Conditioner. https://app.cochat.ai/papers/10.1056/nejm197008062830601
- The paper
- Banaszak, E. F., Thiede, W. H., & Fink, J. N. (1970). Hypersensitivity Pneumonitis Due to Contamination of an Air Conditioner. New England Journal of Medicine. https://doi.org/10.1056/nejm197008062830601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.