The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Percutaneous Balloon Valvuloplasty: A New Method for Treating Congenital Pulmonary-Valve Stenosis
Abstract
TRANSLUMINAL balloon angioplasty has been increasingly accepted as a nonsurgical technique for dilatation of stenotic arteries in the peripheral, renal, and coronary circulations.1 2 3 4 5 6 The physical principles governing balloon angioplasty7 depend on transmission of a controlled radial force through a rigid balloon. The characteristics of the stenotic tissue determine the effectiveness of the dilatation process.Application of the balloon-dilatation principle to intracardiac valves has not been described. However, Semb et al. have relieved congenital pulmonary-valve stenosis by pulling a carbon dioxide-filled balloon from the pulmonary artery to the right ventricle.8 We thought that balloon valvuloplasty of the congenitally stenotic pulmonary valve . . .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979) · New England Journal of Medicine · doi:10.1056/nejm197907123010201 · Cited by 2,419
DOTTER, C. T., & JUDKINS, M. P. (1964) · Circulation · doi:10.1161/01.cir.30.5.654 · Cited by 1,763
“Balloon valvulotomy” of congenital pulmonary valve stenosis with tricuspid valve insufficiency
Semb, B. K. H., Tjønneland, S., Stake, G., & Aabyholm, G. (1979) · CardioVascular and Interventional Radiology · doi:10.1007/bf02552069 · Cited by 107
Cited by
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190811 · Cited by 2,066
ACC/AHA 2008 Guidelines for the Management of Adults With Congenital Heart Disease
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.001 · Cited by 1,533
2006 WRITING COMMITTEE MEMBERS, Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190748 · Cited by 1,114
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190690 · Cited by 867
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Metadata
- Authors
- Kan, J. S., White, R. I., Mitchell, S. E., & Gardner, T. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1982-08-26
- Volume
- 307
- Issue
- 9
- Pages
- 540-542
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2021050418
- Cited by
- 731
- References
- 3
- FWCI
- 16.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous Balloon Valvuloplasty: A New Method for Treating Congenital Pulmonary-Valve Stenosis. https://app.cochat.ai/papers/10.1056/nejm198208263070907
- The paper
- Kan, J. S., White, R. I., Mitchell, S. E., & Gardner, T. J. (1982). Percutaneous Balloon Valvuloplasty: A New Method for Treating Congenital Pulmonary-Valve Stenosis. New England Journal of Medicine. https://doi.org/10.1056/nejm198208263070907
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.