Muscular Subaortic Stenosis: Hemodynamic and Clinical Improvement after Disopyramide

Pollick, Charles · 1982 · New England Journal of Medicine

Abstract

A quarter of a century has passed since Brock's original report1 of the condition characterized by asymmetric septal hypertrophy and a subaortic pressure gradient (muscular subaortic stenosis).2 The pressure gradient may be affected by changes in myocardial contractility, systemic vascular resistance, and ventricular volume.3 Propranolol has little effect on the pressure gradient at rest, but it may diminish the increment that occurs with exercise.4 Verapamil has a greater effect than propranolol in reducing the gradient at rest, although substantial gradients (>50 mm Hg) have persisted even after high doses of intravenous verapamil, and in one patient the gradient markedly increased. . . .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm198210143071607

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 229

Metadata

Authors
Pollick, C.
Venue
New England Journal of Medicine
Published
1982-10-14
Volume
307
Issue
16
Pages
997-999
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2031129844
Cited by
229
References
0
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Muscular Subaortic Stenosis: Hemodynamic and Clinical Improvement after Disopyramide. https://app.cochat.ai/papers/10.1056/nejm198210143071607
The paper
Pollick, C. (1982). Muscular Subaortic Stenosis: Hemodynamic and Clinical Improvement after Disopyramide. New England Journal of Medicine. https://doi.org/10.1056/nejm198210143071607

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.