Magnetic-Susceptibility Measurement of Human Iron Stores
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We made direct noninvasive magnetic measurements of hepatic iron stores with a specially designed superconducting quantum-interference-device (SQUID) susceptometer in 20 normal subjects and in 110 patients with liver disease, iron deficiency, hereditary hemochromatosis, or transfusional iron overload. Magnetic in vivo measurements of liver non-heme iron were closely correlated with chemical in vitro measurements in liver-biopsy specimens (r = 0.98, P less than 10(-5) up to 115 mumol per gram of liver tissue (wet weight) or more. Magnetically determined storage-iron concentrations were below 6.0 mumol per gram in iron-deficient patients and normal men and premenopausal women, but they were raised (9.7 to 31.4 mumol) in 12 of 67 patients with liver disease and were greatly increased (22.9 to 117.7 mumol) in patients with untreated hereditary hemochromatosis or transfusional iron overload. Magnetic measurements of iron stores provide a new quantitative technique for early detection of hereditary hemochromatosis and for rapid evaluation of treatment regimens for transfusional iron overload.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In Europe (Germany and Italy), insurance reimbursement of therapy monitoring is provided [36].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [36]
Citations
Cites
Snedecor, G. W., & Cochran, W. G. (1967) · Cited by 6,573
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,154
Bothwell, T. H., Charlton, R. W., Cook, J. D., & Finch, C. A. (1979) · Blackwell Scientific Publications eBooks · Cited by 730
Hepatic pathology in relatives of patients with hæmochromatosis
Scheuer, P. J., Williams, R., & Muir, A. R. (1962) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700840107 · Cited by 431
Biological Effects of Magnetic Fields
(1995) · Springer eBooks · doi:10.1007/978-1-4684-8352-9 · Cited by 337
Recommendations for Measurement of Serum Iron in Human Blood*
International Committee for Standardization in Haematology (1978) · British Journal of Haematology · doi:10.1111/j.1365-2141.1978.tb01045.x · Cited by 202
Some studies on the biological effects of magnetic fields
Aceto, H., Tobias, C., & Silver, I. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066813 · Cited by 64
Assessment of bone marrow and body iron stores: old techniques and new technologies.
Gm, B., Eh, D., & Jw, H. (1981) · PubMed · Cited by 59
NORMAL HUMAN IRON STORAGE AND ITS RELATION TO ETHANOL CONSUMPTION
Powell, L. W. (1966) · Australasian Annals of Medicine · doi:10.1111/imj.1966.15.2.110 · Cited by 57
Estimation of hepatic iron stores by vivo measurement of magnetic susceptibility.
Bauman, J. H., & Harris, J. (1967) · PubMed · Cited by 52
Self-citation
Research works printed but not linked: 11
- Bauman, 1967, J Lab Clin Med, 70, 246
- Messer, 1967, J Lab Clin Med, 70, 1008
- Harris, 1978, Clin Res, 26, 504A
- Farrell, 1982, Appl Phys Comm, 1, 1
- Brittenham, 1980, Trans Assoc Am Physicians, 93, 156
- Richter, 1978, Am J Pathol, 91, 361
- Weinfeld, 1964, Acta Med Scand [Suppl], 427, 1
- Feldman, 1981, Clin Res, 29, 718A
- Brittenham, 1981, Semin Hematol, 18, 194
- Modell, 1979, Prog Hematol, 11, 267
- Marino, 1977, Physiol Chem Phys, 9, 131
Cited by
Items 301–368 of 368
Иванова, М. П., Morozova, Е. V., VASILIEVA, Y. Y., Rudnitskaya, Y. V., Nabiev, R., Zubarovskaya, L. S., & Afanasyev, B. (2009) · Cellular Therapy and Transplantation · Cited by 7
A study on children's condition thalassemia using neutron activation analysis and other techniques
Krishnan, S., Sturtridge, W. C., Olivieri, N. F., Collins, A. F., Qureshi, R. Y., Krishnan, M., Belluzzo, N., Bogdanovich, E., & Lui, S. M. W. (1994) · Biological Trace Element Research · doi:10.1007/bf02917329 · Cited by 5
Disorders of Iron Metabolism in the Uremic Patient
Tielemans, C. L., Goldman, M., & Vanherweghem, J. (1989) · Seminars in Dialysis · doi:10.1111/j.1525-139x.1989.tb00593.x · Cited by 5
An ultrasensitive magnetoelectric sensor system for the quantitative detection of liver iron
Xi, H., Meng-Chien, L., Qian, X., Zhang, Q., Rupprecht, S., & Yang, Q. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808778 · Cited by 4
Pietrangelo, A., & Torbenson, M. S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-7020-6697-9.00004-2 · Cited by 9
In Vivo Measurement of Hepatic and Cardiac Iron in Cooley's Anemia by Nuclear Resonance Scattering
Zaino, E. C., & Wielopolski, L. (1990) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1990.tb24370.x · Cited by 4
Diagnostic assessment of human iron stores by measurement of hepatic magnetic susceptibility
Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W., Tripp, J. H., Brennan, J. N., & Bellon, E. M. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455955 · Cited by 4
Self-citationMeasurement of Hepatic Iron Concentration
Bacon, B. R. (2014) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.09.003 · Cited by 4
Liver iron concentration thresholds: Where do they really come from?
Müller, L., Hernando, D., Nazeef, M., & Reeder, S. B. (2025) · HemaSphere · doi:10.1002/hem3.70122 · Cited by 3
“” 14 Importantly, these authors did not propose any thresholds.”
Zoller, H. (2025) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-92033-2_16 · Cited by 4
Olivieri, N. F., & Weatherall, D. J. (2006) · Wiley eBooks · doi:10.1002/9780470987001.ch13 · Cited by 3
Thermal injury and changes in the trace elements
Bang, R. L., Mattappallil, A. B., Dashti, H. M., & Al-Bader, A. A. (2000) · The Journal of Trace Elements in Experimental Medicine · doi:10.1002/1520-670x(2000)13:3<255::aid-jtra2>3.0.co;2-j · Cited by 4
Lin, H. J., Conte, W. J., & Rotter, J. I. (1985) · Clinical Genetics · doi:10.1111/j.1399-0004.1985.tb00199.x · Cited by 3
In-vitro measurement of iron concentration in human hepatic tissue by magnetic induction methods
Casañas, R., Scharfetter, H., Altés, A., Remacha, A. F., Sardà, P., Sierra, J., & Rosell, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1017416 · Cited by 3
Novel Biomagnetic Sensing Technique for Characterization of Inflammatory Tissues
Tan, I. C., & Brazdeikis, A. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.893144 · Cited by 3
“Superconducting quantum interference device (SQUID) magnetometry has been used for detecting liver iron stores [4], for sentinel lymph node biopsy [5], and for breast cancer diagnostics [6].”
MethodPituitary in black—hypopituitarism secondary to hemosiderosis
Ippolito, S., Sabatino, J., & Tanda, M. L. (2018) · Endocrine · doi:10.1007/s12020-018-1568-6 · Cited by 3
Alterations in magnetic characteristics produced by intracellular particles
Gordon, R. T., Halperin, W. P., Gordon, D., & Freeman, A. J. (1986) · Journal of Biological Physics · doi:10.1007/bf01857744 · Cited by 3
Braybrook, J. H., & Hall, L. D. (1991) · Polymer International · doi:10.1002/pi.4990260409 · Cited by 3
Sanctis, V. D., Daar, S., Soliman, A. T., Tzoulis, P., Maio, S. D., & KATTAMIS, C. A. (2023) · PubMed Central · doi:10.23750/abm.v94i4.14631 · Cited by 5
SQUID Instruments and Applications
Fagaly, R. L., & Technologies, T. (2005) · Cited by 4
Mehreen, A., Bano, D. S., & Ujala, B. (2017) · The Professional Medical Journal · doi:10.17957/tpmj/17.3678 · Cited by 2
Paramagnetic Pharmaceuticals for Functional Studies
Hall, L. D., & Hogan, P. G. (1987) · Springer eBooks · doi:10.1007/978-1-4471-1410-9_7 · Cited by 2
Adamson, J. W., Cavill, I., Fishbane, S. N., Petersen, J., & Wish, J. B. (1999) · Seminars in Dialysis · doi:10.1046/j.1525-139x.1999.99015.x · Cited by 2
“However, a number of noninvasive methods have been suggested and some, such as the superconducting quantum-interference susceptometer (SQUID), appear promising (20).”
BackgroundPeña, C. G. (2009) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/137 · Cited by 5
Angelucci, E., Barosi, G., Marchetti, M., & Tura, S. (2009) · Haematologica · doi:10.3324/haematol.2008.001651 · Cited by 2
“Our conclusion on the inaccuracy of BLS was mainly grounded on a paper published as an abstract by Piga et al.2 in which the sentence “on average, the LIC data obtained from BLS and biopsy were related by a factor of 0.46” was interpreted as 0.46 being the correlation coefficient of the two measurements.”
MethodInfluentialIron intake and cardiovascular disease
Kartikasari, A. E. R., Georgiou, N., & Marx, J. J. M. (2004) · Elsevier eBooks · doi:10.1533/9781855739499.1.99 · Cited by 2
(2001) · Wiley eBooks · doi:10.1002/9780470696705.refs · Cited by 2
Schilsky, M. L., & Sternlieb, I. (1998) · Humana Press eBooks · doi:10.1007/978-1-4612-1808-1_18 · Cited by 2
Tran, L. N. T., González, K. M. P., Choe, H., Wu, X. Z., Strayer, J., Iyer, P. R., Zborowski, M., Chalmers, J. J., & Gómez‐Pastora, J. (2025) · Micromachines · doi:10.3390/mi16020126 · Cited by 1
“However, traditional approaches for measuring the magnetic susceptibility of biological materials have relied on complex laboratory equipment such as Superconducting Quantum Interference Devices (SQUIDs) and specialized magnetic separation systems [3–10].”
Cho, S. W., Kim, Y., Park, J., & Park, J. H. (2026) · European Radiology · doi:10.1007/s00330-026-12614-4 · Cited by 1
“Normal liver iron was de fi ned as LIC ≤ 1.2 mg/g in accordance with a previous study [18], while moderate iron overload was de fi ned as LIC ≥ 3.2 mg/g, corresponding to the lower threshold for chelation therapy [19, 20].”
InfluentialSong, G. (2009) · Deep Blue (University of Michigan) · Cited by 1
The new generation magnetic-iron-detector to measure the iron overload in the human liver
Gianesin, B., Caminata, A., Beruto, P., Romoli, F., & Marinelli, M. (2013) · Medical Instrumentation · doi:10.7243/2052-6962-1-5 · Cited by 1
“Magnetic Resonance Imaging and biosusceptometry are technique capable to detect iron overload in the body [3-8].”
BackgroundUtility of Labile Plasma Iron Assay in Thalassemia Major Patients
Tripathi, P., Pati, H. P., Mahapatra, M., Tyagi, S., Ahuja, A., & Saxena, R. (2019) · Indian Journal of Hematology and Blood Transfusion · doi:10.1007/s12288-019-01104-x · Cited by 1
ELZAYAT, M. D. M. E.-K. W. A. (2020) · The Medical Journal of Cairo University/The Medical Journal of Cairo University · doi:10.21608/mjcu.2020.110868 · Cited by 1
Pietrangelo, A., & Torbenson, M. S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-7020-8228-3.00004-1 · Cited by 1
Williamson, S. J. (2003) · Wiley eBooks · doi:10.1002/3527600434.eap040 · Cited by 1
Pope, E. (1995) · Library and Archives Canada (Government of Canada) · Cited by 1
Weyhmiller, M., Pakbaz, Z., Butz, J. A., Fung, E. B., Paulson, D. N., Pratt, K., Rowland, J., Vichinsky, E. P., Lal, A., Fischer, R., et al. (2021) · Research Square · doi:10.21203/rs.3.rs-1135845/v1 · Cited by 1
Magnetic Resonance Imaging of Intracranial Hemorrhage
Zimmerman, R. D. (1989) · Springer eBooks · doi:10.1007/978-1-4613-1653-4_1
Iron Chelation Therapy in Beta Thalassaemia Major
Wonke, B. (2004) · Wiley eBooks · doi:10.1002/9780470988398.ch16
Casañas, R., Scharfetter, H., Altés, A., Remacha, A. F., Sardà, P., Sierra, J., Merwa, R., Hollaus, K., & Rosell, J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280788
Tests for hemochromatosis and iron overload
Barton, J. C., Edwards, C. Q., Phatak, P. D., Britton, R. S., & Bacon, B. R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511777035.006
Biomağnetizmanın Gelişimi; İnsan Beynindeki Demirli Bileşenlerin Mağnetik Analizi
Orbay, M. C. Ç. N., & Orbay, N. (2008) · İstanbul Yerbilimleri Dergisi
Overview of Current Chelation Practices
Aydınok, Y. (2011) · Thalassemia Reports · doi:10.4081/thal.2011.s2.e10
Mavrogeni, S. I., Markousis‐Mavrogenis, G., & Kolovou, G. D. (2014) · Thalassemia Reports · doi:10.4081/thal.2014.1859
Assessment of iron nutrition among young japanese females by multivariate analysis
Yamamoto, M., Okubo, M., Oma, M., & Kitano, T. (1987) · Nutrition Research · doi:10.1016/s0271-5317(87)80172-0
Hereditary Hemochromatosis and Iron Overload
Niederau, C. (2009) · Springer eBooks · doi:10.1007/978-3-642-04519-6_28 · Cited by 1
D ISORDERS OF I RON M ETABOLISM
Ancy, N., & Ndrews, C. A. (1999)
MANAGEMENT OF HEREDITARY HEMOCHROMATOSIS
VALBERG, L. S., & Ghent, C. N. (1985)
NEW APPROACHES TO THE TREATMENT OF HEMOGLOBINOPATHIES AND THALASSEMIA
Steinberg, M. H., Forget, B. G., Higgs, D. R., & Weatherall, D. J. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596582.039
Breath-hold spin echosequence for assessing liver iron content
Yang, C.-T., Lu, M., Jaw, F., Peng, S. S., & Shih, T. T. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.07.005
“fa susceptometry using superconducting quantum interference device (SQUID) technology [2,3], and magnetic resonance imaging (MRI) techniques [4–11].”
MethodFischer, R., Eich, E., Engelhardt, R., Kessler, M., & Nielsen, P. B. (2000)
Pontré, B. P. (2006) · UWA Profiles and Research Repository (UWA)
using proton magnetic resonance Noninvasive measurement and imaging of liver iron concentrations
Olynyk, K., Pootrakul, P., Robins, E., Lindeman, R., St, T. G., Clark, P. R., Chua‐anusorn, W., Fleming, A., & Jeffrey, G. P. (2013)
Iolascon, A., D’Apolito, M., Servedio, V., Cimmino, F., & Piga, A. G. (2013)
INFLUENCE OF THE MAGNETIC FIELD ON THE LIVING ORGANISMS AND HUMANS
Naydenov, S., Petkova, S., Getsov, P., & Mardirossian, G. (2019) · Ecological Engineering and Environment Protection · doi:10.32006/eeep.2019.1.1725
Cassarà, F., & Maggio, A. (2013) · Thalassemia Reports · doi:10.4081/thal.2013.s1.e5
Sharma, A. J. L. (2024) · International Journal of Science and Research (IJSR) · doi:10.21275/sr24216105038
Yin, J. L., Raja, K. B., & Ala, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-26711-6.00029-9 · Cited by 1
Fischer, R., Weyhmiller, M., Fung, E. B., Pakbaz, Z., Paulson, D. N., Vichinsky, E. P., Nielsen, P., & Harmatz, P. (2025) · Biochemistry and Biophysics Reports · doi:10.1016/j.bbrep.2025.102340
“Initial studies of BLS suggested a conversion factor (f wdr ) being equal to the wet-to-dry weight ratio (WDR) of 3.46, which assumed a water content of 71.1 % for the liver [7].”
InfluentialVitamin K Antagonists and Novel Oral Anticoagulant
Agnelli, G., & Becattini, C. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-287-8_14
Kwiatkowski, J. L. (2008) · Clínicas pediátricas de Norteamérica
Estudo das propriedades magnéticas de tecidos humanos
Marques, G. M. D. A. (2013) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/e2am-b658 · Cited by 1
History of iron overload disorders
Barton, J. C., Edwards, C. Q., Phatak, P. D., Britton, R. S., & Bacon, B. R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511777035.003 · Cited by 1
50 Years of Innovation: Cryogenics and Superconductivity in Biomedical Applications
Shu, Q.-S., Radebaugh, R., & Fagaly, R. L. (2026) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1344/1/012122
“Figure 5 Left, coil-in-vacuum system for combining SQUID sensors and superconducting magnetic to measure magnetic susceptibility of internal organs [16].”
Hemochromatosis: Clinical Aspects and Response to Therapy
Grace, N. D. (1989) · Springer eBooks · doi:10.1007/978-1-4684-7041-3_23
Metadata
- Authors
- Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M.
- ORCID
- Brittenham, Gary M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1982-12-30
- Volume
- 307
- Issue
- 27
- Pages
- 1671-1675
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2338855129
- Cited by
- 367
- References
- 17
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 7 · 2017: 10 · 2016: 9 · 2015: 6 · 2014: 9 · 2013: 13 · 2012: 7
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
- Keywords
- hepatic iron stores, magnetic susceptibility, hereditary hemochromatosis, transfusional iron overload, iron deficiency, liver disease, liver biopsy
- MeSH terms
- Iron Deficiencies, Female, Ferritins, Hemochromatosis, Hemosiderin, Humans, Iron, Liver, Liver Diseases, Magnetics, Male, Methods, Tissue Distribution, Transfusion Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.