Magnetic-Susceptibility Measurement of Human Iron Stores
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
We made direct noninvasive magnetic measurements of hepatic iron stores with a specially designed superconducting quantum-interference-device (SQUID) susceptometer in 20 normal subjects and in 110 patients with liver disease, iron deficiency, hereditary hemochromatosis, or transfusional iron overload. Magnetic in vivo measurements of liver non-heme iron were closely correlated with chemical in vitro measurements in liver-biopsy specimens (r = 0.98, P less than 10(-5) up to 115 mumol per gram of liver tissue (wet weight) or more. Magnetically determined storage-iron concentrations were below 6.0 mumol per gram in iron-deficient patients and normal men and premenopausal women, but they were raised (9.7 to 31.4 mumol) in 12 of 67 patients with liver disease and were greatly increased (22.9 to 117.7 mumol) in patients with untreated hereditary hemochromatosis or transfusional iron overload. Magnetic measurements of iron stores provide a new quantitative technique for early detection of hereditary hemochromatosis and for rapid evaluation of treatment regimens for transfusional iron overload.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In Europe (Germany and Italy), insurance reimbursement of therapy monitoring is provided [36].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [36]
Citations
Cites
Snedecor, G. W., & Cochran, W. G. (1967) · Cited by 6,573
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,154
Bothwell, T. H., Charlton, R. W., Cook, J. D., & Finch, C. A. (1979) · Blackwell Scientific Publications eBooks · Cited by 730
Hepatic pathology in relatives of patients with hæmochromatosis
Scheuer, P. J., Williams, R., & Muir, A. R. (1962) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700840107 · Cited by 431
Biological Effects of Magnetic Fields
(1995) · Springer eBooks · doi:10.1007/978-1-4684-8352-9 · Cited by 337
Recommendations for Measurement of Serum Iron in Human Blood*
International Committee for Standardization in Haematology (1978) · British Journal of Haematology · doi:10.1111/j.1365-2141.1978.tb01045.x · Cited by 202
Some studies on the biological effects of magnetic fields
Aceto, H., Tobias, C., & Silver, I. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066813 · Cited by 64
Assessment of bone marrow and body iron stores: old techniques and new technologies.
Gm, B., Eh, D., & Jw, H. (1981) · PubMed · Cited by 59
NORMAL HUMAN IRON STORAGE AND ITS RELATION TO ETHANOL CONSUMPTION
Powell, L. W. (1966) · Australasian Annals of Medicine · doi:10.1111/imj.1966.15.2.110 · Cited by 57
Estimation of hepatic iron stores by vivo measurement of magnetic susceptibility.
Bauman, J. H., & Harris, J. (1967) · PubMed · Cited by 52
Self-citation
Research works printed but not linked: 11
- Bauman, 1967, J Lab Clin Med, 70, 246
- Messer, 1967, J Lab Clin Med, 70, 1008
- Harris, 1978, Clin Res, 26, 504A
- Farrell, 1982, Appl Phys Comm, 1, 1
- Brittenham, 1980, Trans Assoc Am Physicians, 93, 156
- Richter, 1978, Am J Pathol, 91, 361
- Weinfeld, 1964, Acta Med Scand [Suppl], 427, 1
- Feldman, 1981, Clin Res, 29, 718A
- Brittenham, 1981, Semin Hematol, 18, 194
- Modell, 1979, Prog Hematol, 11, 267
- Marino, 1977, Physiol Chem Phys, 9, 131
Cited by
Andrews, N. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412607 · Cited by 2,130
Hemorrhagic Complications of Anticoagulant Treatment
Levine, M. N., Raskob, G., Landefeld, S., & Kearon, C. (2001) · Chest · doi:10.1378/chest.119.1_suppl.108s · Cited by 1,134
Iron-Chelating Therapy and the Treatment of Thalassemia
Olivieri, N. F., & Brittenham, G. M. (1997) · Blood · doi:10.1182/blood.v89.3.739 · Cited by 1,089
Self-citationWood, J. C., Enriquez, C., Ghugre, N., Tyzka, J. M., Carson, S., Nelson, M. D., & Coates, T. D. (2005) · Blood · doi:10.1182/blood-2004-10-3982 · Cited by 1,045
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
“The references were chosen to cover major headings related to observations of iron effects in brain [1–131], liver iron [132–146], MRI developments related to signal effects of iron [147–174], relaxation effects [175–209], magnetic field artifacts [210–218], measuring field effects [219–231] and targeted contrast agen…”
BackgroundNoninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance
St. Pierre, T. G., Clark, P. R., Chua-anusorn, W., Fleming, A. J., Jeffrey, G. P., Olynyk, J. K., Pootrakul, P., Robins, E., & Lindeman, R. (2005) · Blood · doi:10.1182/blood-2004-01-0177 · Cited by 909
Survival in Medically Treated Patients with Homozygous β-Thalassemia
Olivieri, N. F., Nathan, D. G., MacMillan, J. H., Wayne, A. S., Liu, P. P., McGee, A., Martin, M., Koren, G., & Cohen, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409013310903 · Cited by 852
Brittenham, G. M., Griffith, P. M., Nienhuis, A. W., McLaren, C. E., Young, N. S., Tucker, E. E., Allen, C. J., Farrell, D. E., & Harris, J. W. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409013310902 · Cited by 829
Self-citationHemorrhagic Complications of Anticoagulant and Thrombolytic Treatment
Schulman, S., Beyth, R. J., Kearon, C., & Levine, M. N. (2008) · Chest · doi:10.1378/chest.08-0674 · Cited by 740
Olivieri, N. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907083410207 · Cited by 728
Cappellini, M. D. (2006) · Blood · doi:10.1182/blood-2005-08-3430 · Cited by 717
Non-invasive assessment of hepatic iron stores by MRI
Gandon, Y., Olivié, D., Guyader, D., Aubé, C., Oberti, F., Sebille, V, & Deugnier, Y. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15436-6 · Cited by 671
Magnetite biomineralization in the human brain.
Kirschvink, J. L., Kobayashi-Kirschvink, A., & Woodford, B. J. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.16.7683 · Cited by 614
Body iron metabolism and pathophysiology of iron overload
Kohgo, Y., Ikuta, K., Ohtake, T., Torimoto, Y., & Kato, J. (2008) · International Journal of Hematology · doi:10.1007/s12185-008-0120-5 · Cited by 616
“Notably, other methods that are becoming increasingly important include physical methods such as the superconducting quantum-interference device (SQUID) and magnetic resonance imaging (MRI).”
InfluentialHepatic Iron Concentration and Total Body Iron Stores in Thalassemia Major
Angelucci, E., Brittenham, G. M., McLaren, C. E., Ripalti, M., Baronciani, D., Giardini, C., Galimberti, M., Polchi, P., & Lucarelli, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008033430503 · Cited by 607
Self-citationEASL clinical practice guidelines for HFE hemochromatosis
European Association for the Study of the Liver (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2010.03.001 · Cited by 587
Hemorrhagic Complications of Anticoagulant Treatment
Levine, M. N., Raskob, G., Beyth, R. J., Kearon, C., & Schulman, S. (2004) · Chest · doi:10.1378/chest.126.3_suppl.287s · Cited by 515
Pennell, D. J. (2006) · Blood · doi:10.1182/blood-2005-07-2948 · Cited by 495
Vlachos, A., Ball, S., Dahl, N., Alter, B. P., Sheth, S., Ramenghi, U., Meerpohl, J., Karlsson, S., Liu, J. M., Leblanc, T., et al. (2008) · British Journal of Haematology · doi:10.1111/j.1365-2141.2008.07269.x · Cited by 478
Bugianesi, E., Manzini, P., D'Antico, S., Vanni, E., Longo, F., Leone, N., Massarenti, P., Piga, A., Marchesini, G., & Rizzetto, M. (2004) · Hepatology · doi:10.1002/hep.20023 · Cited by 440
Long-Term Safety and Effectiveness of Iron-Chelation Therapy with Deferiprone for Thalassemia Major
Olivieri, N. F., Brittenham, G. M., McLaren, C. E., Templeton, D. M., Cameron, R. G., McClelland, R. A., Burt, A. D., & Fleming, K. A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390701 · Cited by 420
Self-citationAnderson, L. J., Westwood, M. A., Holden, S., Davis, B., Prescott, E., Wonke, B., Porter, J. B., Malcolm Walker, J., & Pennell, D. J. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.05202.x · Cited by 414
“…of iron clearance, patients with heart failure should not be managed by liver iron measurements alone, whether by biopsy, magnetic resonance or quantum interference (Brittenham et al, 1982), and measurement of myocardial T2* and ventricular function are important for monitoring of cardiac risk.”
BackgroundOverview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Witte, D. L., Crosby, W. H., Edwards, C. Q., Fairbanks, V. F., & Mitros, F. A. (1996) · Clinica Chimica Acta · doi:10.1016/0009-8981(95)06212-2 · Cited by 321
Iron-Chelation Therapy with Oral Deferiprone in Patients with Thalassemia Major
Olivieri, N. F., Brittenham, G. M., Matsui, D., Berkovitch, M., Blendis, L. M., Cameron, R. G., McClelland, R. A., Liu, P. P., Templeton, D. M., & Koren, G. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504063321404 · Cited by 324
Self-citationQuantification of liver iron with MRI: State of the art and remaining challenges
Hernando, D., Levin, Y. S., Sirlin, C. B., & Reeder, S. B. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24584 · Cited by 280
“Additionally, because iron in the body is paramagnetic, it affects the susceptibility of tissue, resulting in macroscopic changes in the B0 field (the basis of SQUID biosusceptometry).”
InfluentialNoninvasive measurement of iron: report of an NIDDK workshop
Brittenham, G. M., & Badman, D. G. (2003) · Blood · doi:10.1182/blood-2002-06-1723 · Cited by 274
Self-citationVichinsky, E., Onyekwere, O., Porter, J., Swerdlow, P., Eckman, J., Lane, P., Files, B., Hassell, K., Kelly, P., Wilson, F., et al. (2007) · British Journal of Haematology · doi:10.1111/j.1365-2141.2006.06455.x · Cited by 271
“E-mail: evichinsky@mail.cho.org *See Appendix I for a complete list of investigators Summary Deferasirox is a once-daily, oral iron chelator developed for treating transfusional iron overload.”
BackgroundMethodBrittenham, G. M., Cohen, A. R., McLaren, C. E., Martin, M. B., Griffith, P. M., Nienhuis, A. W., Young, N. S., Allen, C. J., Farrell, D. E., & Harris, J. W. (1993) · American Journal of Hematology · doi:10.1002/ajh.2830420116 · Cited by 270
Self-citationPiga, A. G., Galanello, R., Forni, G. L., Cappellini, M. D., Origa, R., Zappu, A., Donato, G., Bordone, E., Lavagetto, A., Zanaboni, L., et al. (2006) · PubMed · Cited by 264
Nano Superconducting Quantum Interference device: A powerful tool for nanoscale investigations
Granata, C., & Vettoliere, A. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.001 · Cited by 249
Schweser, F., Sommer, K., Deistung, A., & Reichenbach, J. R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.067 · Cited by 241
“Bulkmagnetic susceptibility is a fundamental physical tissue property, which is long known to reflect clinically relevant tissue characteristics, such as tissue iron content (Bauman and Harris, 1967; Brittenham et al., 1982; Senftle and Thorpe, 1961) or blood oxygenation level (Ogawa et al., 1990).”
BackgroundEstimates of iron sufficiency in the US population
Cook, J., Skikne, B., Lynch, Sr., & Reusser, M. (1986) · Blood · doi:10.1182/blood.v68.3.726.726 · Cited by 247
Kushner, J. P., Porter, J. P., & Olivieri, N. F. (2001) · Hematology · doi:10.1182/asheducation-2001.1.47 · Cited by 245
Desforges, J. F., Edwards, C. Q., & Kushner, J. P. (1993) · New England Journal of Medicine · doi:10.1056/nejm199306033282208 · Cited by 247
Magnetic resonance imaging measurement of iron overload
Wood, J. C. (2007) · Current Opinion in Hematology · doi:10.1097/moh.0b013e3280d2b76b · Cited by 241
“183 estimation including the superconducting quantum interference device (SQUID) [23,24], quantitative computed tomography (qCT) [25–27], and MRI [28–30].”
MethodTelfer, P. T., Prestcott, E., Holden, S., Walker, M., Hoffbrand, A. V., & Wonke, B. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02298.x · Cited by 240
“Sequential monitoring of liver iron either by repeated biopsy or by using non-invasive methods, such as magnetic susceptometry (Brittenham et al, 1982) or quantitative magnetic resonance imaging (MRI) (Dixon et al, 1994), are probably of more use in monitoring iron burden and should be assessed in…”
MethodSQUID magnetometers for low-frequency applications
Ryh�nen, T., Sepp�, H., Ilmoniemi, R., & Knuutila, J. (1989) · Journal of Low Temperature Physics · doi:10.1007/bf00681735 · Cited by 204
Angelucci, E., Barosi, G., Camaschella, C., Cappellini, M. D., Cazzola, M., Galanello, R., Marchetti, M., Piga, A., & Tura, S. (2008) · Haematologica · doi:10.3324/haematol.12413 · Cited by 203
“SF, LIC 2006 mg/kg based on initial LIC; label phase II trial mg/gdw)=36 DFX=15 (3-54) (1015-15578) by SQUID; DFX=10 mg/kg or DFX (LIC >7 DFX=3460 compliance 10-30 mg/kg according to mgFE/gdw)=64 (1082-12901) to baseline LIC treatment”
MethodPathophysiology and Clinical Manifestations of the -Thalassemias
Nienhuis, A. W., & Nathan, D. G. (2012) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a011726 · Cited by 180
“Magnetic susceptibility imaging was the first noninvasive quantitative technique, which established a correlation between liver iron concentration by biopsy and this noninvasive measurement (Brittenham et al. 1982).”
BackgroundIron Overload Disorders: Natural History, Pathogenesis, Diagnosis, and Therapy
McLaren, G. D., Muir, W. A., Kellermeyer, R. W., & Jacobs, A. (1983) · CRC Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368309165764 · Cited by 189
Self-citationMR evaluation of age-related increase of brain iron in young adult and older normal males
Bartzokis, G., Beckson, M., Hance, D. B., Marx, P., Foster, J. A., & Marder, S. R. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00234-2 · Cited by 181
Effect of transfusional iron intake on response to chelation therapy in β-thalassemia major
Cohen, A. R., Glimm, E., & Porter, J. B. (2008) · Blood · doi:10.1182/blood-2007-08-109306 · Cited by 180
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores
Bartzokis, G., Aravagiri, M., Oldendorf, W. H., Mintz, J., & Marder, S. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290406 · Cited by 172
Jensen, P. D., Jensen, F. T., Christensen, T., Eiskjær, H., Baandrup, U., & Nielsen, J. L. (2003) · Blood · doi:10.1182/blood-2002-09-2754 · Cited by 174
The effect of erythroid hyperplasia on iron balance
Pootrakul, P., Kitcharoen, K., Yansukon, P., Wasi, P., Fucharoen, S., Charoenlarp, P., Brittenham, G., Pippard, M., & Finch, C. (1988) · Blood · doi:10.1182/blood.v71.4.1124.1124 · Cited by 168
Self-citationIron Chelators for Thalassaemia
Hershko, C., Konijn, A. M., & Link, G. (1998) · British Journal of Haematology · doi:10.1046/j.1365-2141.1998.00726.x · Cited by 160
“Response to treatment may be assessed by serum ferritin measurements, liver biopsies, computed tomography, or magnetic susceptibility (SQUID) (Brittenham et al, 1982).”
BackgroundIron overload is a determinant of morbidity and mortality in adult patients with sickle cell disease
Ballas, S. K. (2001) · Seminars in Hematology · doi:10.1016/s0037-1963(01)90058-7 · Cited by 153
SQUIDs for nondestructive evaluation
Jenks, W. G., Sadeghi, S. H. H., & Wikswo, J. P. (1997) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/30/3/002 · Cited by 152
Iron overload cardiomyopathies: New insights into an old disease
Liu, P. J., & Olivieri, N. F. (1994) · Cardiovascular Drugs and Therapy · doi:10.1007/bf00877096 · Cited by 152
“have validated and applied the technique of using a superquantum interference device (SQUID) to detect the iron levels in large organs such as the liver, taking advantage of the fact that iron in tissues can generate subtle magnetic field interferences [39].”
MethodSchenck, J. F. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49617.x · Cited by 149
Voskaridou, E., Douskou, M., Terpos, E., Papassotiriou, I., Stamoulakatou, A., Ourailidis, A., Loutradi, A., & Loukopoulos, D. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.05104.x · Cited by 148
“However, its complexity, high cost and limited access (available in approximately three centres worldwide so far) have restricted its general application (Brittenham et al, 1982; Fischer, 1998).”
BackgroundBalfour, J. A. B., & Foster, R. H. (1999) · Drugs · doi:10.2165/00003495-199958030-00021 · Cited by 146
“[78] Computer-enhanced dual channel magnetic susceptometry (SQUID) provides a noninvasive and more accurate means of measuring hepatic iron stores,[79] but requires expensive equipment which is only available at a very small number of specialised centres.”
Non‐invasive quantitation of liver iron‐overload by magnetic resonance imaging
Kaltwasser, J. P., Gottschalk, R., Schalk, K. P., & Hartl, W. (1990) · British Journal of Haematology · doi:10.1111/j.1365-2141.1990.tb02596.x · Cited by 146
Iolascon, A., d'Apolito, M., Servedio, V., Cimmino, F., Piga, A., & Camaschella, C. (2006) · Blood · doi:10.1182/blood-2005-06-2477 · Cited by 144
Iron overload in hematopoietic cell transplantation
Majhail, N. S., Lazarus, H. M., & Burns, L. J. (2008) · Bone Marrow Transplantation · doi:10.1038/bmt.2008.99 · Cited by 144
Galanello, R., Piga, A. G., Forni, G. L., Bertrand, Y., Foschini, M. L., Bordone, E., Leoni, G., Lavagetto, A., Zappu, A., Longo, F., et al. (2006) · PubMed · Cited by 138
Jensen, P. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04838.x · Cited by 133
“…between chemically measured LIC and the magnetic measurements for instruments operating in Hamburg (r ¼ 0Æ99) (Fischer et al, 1992) and in Cleveland (r ¼ 0Æ98) (Brittenham et al, 1982), demonstrating direct linearity up to at least 200 lmol/g ww (about 670 lmol/g dw) (Brittenham et al, 1982).”
BackgroundIn vivo evaluation of brain iron in Alzheimer's disease and normal subjects using MRI
Bartzokis, G., Sultzer, D. L., Mintz, J., Holt, L. E., Marx, P., Phelan, C., & Marder, S. R. (1994) · Biological Psychiatry · doi:10.1016/0006-3223(94)90047-7 · Cited by 140
Angelucci, E., BARONCIANI, D., Lucarelli, G., Baldassarri, M., GALIMBERTI, M., Giardini, C., Martinelli, F., Polchi, P., Polizzi, V., Ripalti, M., et al. (1995) · British Journal of Haematology · doi:10.1111/j.1365-2141.1995.tb08412.x · Cited by 133
Estimating tissue iron burden: current status and future prospects
Wood, J. C. (2015) · British Journal of Haematology · doi:10.1111/bjh.13374 · Cited by 131
“…approaches to liver iron quantification have been developed, including computerized tomography (CT) (Wood et al, 2011b), magnetic susceptometry (Brittenham et al, 1982; Nielsen et al, 2000; Gianesin et al, 2012), and MRI (Anderson et al, 2001; St Pierre et al, 2005; Wood et al, 2005a; Hankins…”
Scharfetter, H., Casañas, R., & Rosell, J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813533 · Cited by 148
“To our knowledge, the only noninvasive measurement method so far tested for hepatic iron overload in humans is based on SQUIDs [14], [15] or on MRI [16].”
MethodCanavese, C., Bergamo, D., Ciccone, G., Longo, F., Fop, F., Thea, A., Martina, G., & Piga, A. G. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00480.x · Cited by 130
“The limits for mild, moderate, and severe iron overload have been chosen on our experience, in accordance with the literature [16, 48].”
MethodPierre, T. G. S., El-Beshlawy, A. M., Elalfy, M. S., Al‐Jefri, A., Zir, K. A., Daar, S., Habr, D., Kriemler‐Krahn, U., & Taher, A. T. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24854 · Cited by 129
“mination of body iron stores can also be used in patients with HH to identify patients at risk of iron-induced organ damage who would benefit from phlebotomy therapy (2).”
BackgroundPakbaz, Z., Fischer, R., Fung, E., Nielsen, P., Harmatz, P., & Vichinsky, E. (2007) · Pediatric Blood & Cancer · doi:10.1002/pbc.21275 · Cited by 128
“The normal LIC measured by SQUID is 90–340 mg Fe/g-liver wet weight [8].”
BackgroundThe laboratory assessment of iron status — an update
Worwood, M. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(96)06488-1 · Cited by 127
Treatment of Cooley's anemia [see comments]
Fosburg, M. T., & Nathan, D. (1990) · Blood · doi:10.1182/blood.v76.3.435.435 · Cited by 126
Assessment of tissue iron overload by nuclear magnetic resonance imaging
Johnston, D. L., Rice, L., Vick, G. W., Hedrick, T. D., & Rokey, R. (1989) · The American Journal of Medicine · doi:10.1016/s0002-9343(89)80481-4 · Cited by 124
Iron Overload: Causes And Consequences
Gordeuk, V. R., Bacon, B. R., & Brittenham, G. M. (1987) · Annual Review of Nutrition · doi:10.1146/annurev.nu.07.070187.002413 · Cited by 125
Self-citationTreatment with Azacitidine of Patients with End-Stage β-Thalassemia
Lowrey, C. H., & Nienhuis, A. W. (1993) · New England Journal of Medicine · doi:10.1056/nejm199309163291205 · Cited by 124
Use of Magnetic Resonance Imaging to Monitor Iron Overload
Wood, J. C. (2014) · Hematology/Oncology Clinics of North America · doi:10.1016/j.hoc.2014.04.002 · Cited by 114
“The first devices to accomplish this used superconducting magnetic coils and were known as superconducting quantum interference devices (SQUIDs) [33, 34].”
MethodHeart failure in β-thalassemia syndromes: A decade of progress
Hahalis, G. N., Alexopoulos, D., Kremastinos, D. T., & Zoumbos, N. C. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.02.021 · Cited by 134
Kirschvink, J. L. (1989) · Bioelectromagnetics · doi:10.1002/bem.2250100304 · Cited by 111
A biomagnetic system forin vivocancer imaging
Flynn, E. R., & Bryant, H. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/016 · Cited by 107
Hyodo, T., Yada, N., Hori, M., Maenishi, O., Lamb, P., Sasaki, K., Onoda, M., Kudo, M., Mochizuki, T., & Murakami, T. (2017) · Radiology · doi:10.1148/radiol.2017160130 · Cited by 103
Diagnosis and management of transfusion iron overload: The role of imaging
Wood, J. C. (2007) · American Journal of Hematology · doi:10.1002/ajh.21099 · Cited by 105
“SQUID was among the first noninvasive techniques used to measure body iron loading [16].”
MethodClinical Relevance of Anemia and Transfusion Iron Overload in Myelodysplastic Syndromes
Cazzola, M., Porta, M. G. D., & Malcovati, L. (2008) · Hematology · doi:10.1182/asheducation-2008.1.166 · Cited by 114
A valine deletion of ferroportin 1: a common mutation in hemochromatosis type 4?
Roetto, A., Merryweather-Clarke, A. T., Daraio, F., Livesey, K., Pointon, J. J., Barbabietola, G., Piga, A., Mackie, P. H., Robson, K. J. H., & Camaschella, C. (2002) · Blood · doi:10.1182/blood-2002-03-0693 · Cited by 102
Chapin, J. C., & Giardina, P. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-35762-3.00040-8 · Cited by 108
Usefulness and limitations of laboratory and hepatic imaging studies in iron-storage disease
Bonkovsky, H. L., Slaker, D. P., Bills, E. B., & Wolf, D. C. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)90629-f · Cited by 100
Magnetic Resonance Imaging in Parkinsonism
Olanow, C. W. (1992) · Neurologic Clinics · doi:10.1016/s0733-8619(18)30218-4 · Cited by 117
Bulte, J. W. M., Miller, G. F., Vymazal, J., Brooks, R. A., & Frank, J. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370409 · Cited by 96
“Non-invasive tests for hepatic iron overload include dual energy computed tomography (5-7), nuclear resonant scattering of gamma rays (8, 91, magnetic susceptibilty measurements (10, 11), and magnetic resonance (MR) imaging (12-18).”
BackgroundAge-Dependent Normal Values of T2* and T2′ in Brain Parenchyma
Siemonsen, S., Finsterbusch, J., Matschke, J., Lorenzen, A., Ding, X. Q., & Fiehler, J. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0951 · Cited by 105
Monitoring chelation therapy to achieve optimal outcome in the treatment of thalassaemia
Porter, J. B., & Davis, B. A. (2002) · Best Practice & Research Clinical Haematology · doi:10.1053/beha.2002.0214 · Cited by 104
Ghugre, N. R., Coates, T. D., Nelson, M. D., & Wood, J. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20697 · Cited by 96
“8 (32), the observed liver R1 relaxivity was approximately 25% of that for either free or liposomal-ferritin analyzed using the same instrument (33).”
MethodMarco, V. D., Capra, M., Angelucci, E., Borgna‐Pignatti, C., Telfer, P. T., Harmatz, P., Kattamis, A., Prossamariti, L., Filosa, A., Rund, D. G., et al. (2010) · Blood · doi:10.1182/blood-2009-11-248724 · Cited by 105
Self-citationNewer nanoparticles in hyperthermia treatment and thermometry
Sharma, R. D., & J.Chen, C. (2008) · Journal of Nanoparticle Research · doi:10.1007/s11051-008-9548-z · Cited by 97
Biological Significance of Iron-Related Magnetic Resonance Imaging Changes in the Brain
Pujol, J., Junque, C., Vendrell, P., Grau, J. M., Marti-Vilalta, J. L., Olive, C., & Gili, J. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530310053012 · Cited by 88
Effect of surface charge on the cellular uptake of fluorescent magnetic nanoparticles
Kralj, S., Rojnik, M., Romih, R., Jagodič, M., Kos, J., & Makovec, D. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-1151-7 · Cited by 88
“…device (SQUID), the most sensitive detector for measuring magnetic fields (Ge et al. 2009), has been used for detecting liver iron stores (Brittenham et al. 1982), for breast-cancer diagnostics (Flynn and Bryant 2005), and for detecting the minute magnetic field perturbations associated…”
BackgroundMultiple hormone deficiencies in children with hemochromatosis
Oerter, K. E., Kamp, G. A., Munson, P. J., Nienhuis, A. W., CASSORLA, F. G., & Manasco, P. K. (1993) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.76.2.357 · Cited by 96
Iron Overload in Sickle Cell Disease
Raghupathy, R., Manwani, D. G., & Little, J. A. (2010) · Advances in Hematology · doi:10.1155/2010/272940 · Cited by 95
Imaging of brain iron by magnetic resonance: T2 relaxation at different field strengths
Schenck, J. F. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00203-e · Cited by 91
Papakonstantinou, O., Maris, T. G., Kostaridou, V., Gouliamos, A. D., Koutoulas, G. K., Kalovidouris, A. E., Papavassiliou, G. B., Kordas, G. C., Kattamis, C., Vlahos, L. J., et al. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00041-e · Cited by 82
Depletion of excessive liver iron stores with desferrioxamine
Cohen, A., Martin, M., & Schwartz, E. (1984) · British Journal of Haematology · doi:10.1111/j.1365-2141.1984.tb06096.x · Cited by 81
Long-Term Fate of Magnetic Particles in Mice: A Comprehensive Study
Zelepukin, I. V., Yaremenko, A. V., Ivanov, I. N., Yuryev, M. V., Cherkasov, V. R., Deyev, S. M., Nikitin, P. I., & Nikitin, M. P. (2021) · ACS Nano · doi:10.1021/acsnano.1c00687 · Cited by 82
Topiwala, A., Wang, C., Ebmeier, K. P., Burgess, S., Bell, S., Levey, D. F., Zhou, H., McCracken, C., Roca‐Fernández, A., Petersen, S. E., et al. (2022) · PLoS Medicine · doi:10.1371/journal.pmed.1004039 · Cited by 88
“Better insights require well-powered samples with genetic data and concurrent measurement of iron accumulation in brain and liver, the most reliable indicator of the body’s iron stores [15,16].”
BackgroundLimitations of Magnetic Resonance Imaging in Measurement of Hepatic Iron
Angelucci, E., Giovagnoni, A., Valeri, G., Paci, E., Ripalti, M., Muretto, P., McLaren, C. E., Brittenham, G. M., & Lucarelli, G. (1997) · Blood · doi:10.1182/blood.v90.12.4736 · Cited by 79
Self-citationNon-invasive assessment of tissue iron overload
Fischer, R., & Harmatz, P. (2009) · Hematology · doi:10.1182/asheducation-2009.1.215 · Cited by 89
Primary Iron Overload in African Americans
Wurapa, R. K., Gordeuk, V. R., Brittenham, G. M., Khiyami, A., Schechter, G. P., & Edwards, C. Q. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(96)00053-8 · Cited by 78
Self-citation
Metadata
- Authors
- Brittenham, G. M., Farrell, D. E., Harris, J. W., Feldman, E. S., Danish, E. H., Muir, W. A., Tripp, J. H., & Bellon, E. M.
- ORCID
- Brittenham, Gary M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1982-12-30
- Volume
- 307
- Issue
- 27
- Pages
- 1671-1675
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2338855129
- Cited by
- 367
- References
- 17
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 7 · 2017: 10 · 2016: 9 · 2015: 6 · 2014: 9 · 2013: 13 · 2012: 7
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
- Keywords
- hepatic iron stores, magnetic susceptibility, hereditary hemochromatosis, transfusional iron overload, iron deficiency, liver disease, liver biopsy
- MeSH terms
- Iron Deficiencies, Female, Ferritins, Hemochromatosis, Hemosiderin, Humans, Iron, Liver, Liver Diseases, Magnetics, Male, Methods, Tissue Distribution, Transfusion Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.