Adjusted versus Fixed-Dose Subcutaneous Heparin in the Prevention of Deep-Vein Thrombosis after Total Hip Replacement
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Venous thromboembolism after total hip replacement continues to be a serious problem. We conducted a study to determine whether adjustment of the dose of subcutaneous heparin to yield partial thromboplastin times in the high-normal range results in a greater reduction of postoperative deep-vein thrombosis than fixed doses of heparin. Seventy-nine patients undergoing elective hip arthroplasty were randomly divided into two groups two days before surgery. Group 1 (41 patients) received a fixed dose of 3500 IU of heparin subcutaneously ever eight hours; 16 of the 41 (39 per cent) had deep-vein thrombosis diagnosed by venography. Group 2 (38 patients) was started on the same dose, which was then adjusted to keep the activated partial thromboplastin time between 31.5 and 36 seconds. From the day of operation to the eighth postoperative day these patients needed progressively more heparin to maintain the activated partial thromboplastin time in the prescribed range. Only 5 of the 38 (13 per cent) had deep-vein thrombosis (P less than 0.01), and the number of thrombi in proximal veins was also lower in this group (P = 0.003). The number of units of blood transfused, the frequency of postoperative wound hematomas, and the drop in hemoglobin levels were identical in the two groups. Adjusted low-dose heparin prophylaxis appears to be a safe and efficacious method to reduce the frequency of deep-vein thrombosis in patients undergoing total hip replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adjusted Subcutaneous Heparin versus Warfarin Sodium in the Long-Term Treatment of Venous Thrombosis
Hull, R., Delmore, T., Carter, C., Hirsh, J., Genton, E., Gent, M., Turpie, G., & McLaughlin, D. (1982) · New England Journal of Medicine · doi:10.1056/nejm198201283060401 · Cited by 436
TRIPLET PREGNANCY AFTER PULSATILE ADMINISTRATION OF GONADOTROPIN RELEASING HORMONE
Bogchelman, D., Lappöhn, R. E., & Janssens, J. (1982) · The Lancet · doi:10.1016/s0140-6736(82)91180-1 · Cited by 378
FAILURE OF LOW-DOSE HEPARIN TO PREVENT DEEP-VEIN THROMBOSIS AFTER HIP-REPLACEMENT ARTHROPLASTY
Hampson, W. G. J., Lucas, H. K., Harris, F. C., Roberts, P. H., McCall, I. W., Jackson, P. C., Powell, N. L., & Staddon, G. E. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91068-x · Cited by 135
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
Antithrombotic Therapy for Venous Thromboembolic Disease
Hyers, T. M., Agnelli, G., Hull, R. D., Morris, T. A., Samama, M., Tapson, V., & Weg, J. G. (2001) · Chest · doi:10.1378/chest.119.1_suppl.176s · Cited by 2,042
Hirsh, J., Warkentin, T. E., Shaughnessy, S. G., Anand, S. S., Halperin, J. L., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (2001) · Chest · doi:10.1378/chest.119.1_suppl.64s · Cited by 1,580
Heparin and Low-Molecular-Weight Heparin
Hirsh, J., Warkentin, T. E., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (1998) · Chest · doi:10.1378/chest.114.5_supplement.489s · Cited by 1,031
Oates, J. A., Wood, A. J. J., & Hirsh, J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105303242206 · Cited by 830
Prevention of Venous Thromboembolism in General Surgical Patients: Results of Meta-analysis
CLAGETT, G. P., & REISCH, J. S. (1988) · Annals of Surgery · doi:10.1097/00000658-198808000-00016 · Cited by 691
Hirsh, J., & Hoak, J. (1996) · Circulation · doi:10.1161/01.cir.93.12.2212 · Cited by 635
Hirsh, J., Anand, S. S., Halperin, J. L., & Fuster, V. (2001) · Circulation · doi:10.1161/01.cir.103.24.2994 · Cited by 565
Hirsh, J., Dalen, J. E., Deykin, D., & Toller, L. (1992) · Chest · doi:10.1378/chest.102.4_supplement.337s · Cited by 558
Hirsh, J., Raschke, C. R., Warkentin, T. E., Dalen, J. E., Deykin, D., & Poller, L. (1995) · Chest · doi:10.1378/chest.108.4_supplement.258s · Cited by 394
Low molecular weight heparin in prevention of perioperative thrombosis.
Leizorovicz, A., Haugh, M. C., Chapuis, F. R., Samama, M. M., & Boissel, J. P. (1992) · BMJ · doi:10.1136/bmj.305.6859.913 · Cited by 378
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Geerts, W., Heit, J. A., Knudson, M., Lieberman, J. R., Merli, G. J., & Wheeler, H. B. (1998) · Chest · doi:10.1378/chest.114.5_supplement.531s · Cited by 378
Prevention of Venous Thromboembolism
Clagett, G. P., Anderson, F. A., Heit, J., Levine, M. N., & Wheeler, H. B. (1995) · Chest · doi:10.1378/chest.108.4_supplement.312s · Cited by 364
Weinmann, E. E., & Salzman, E. W. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412153312407 · Cited by 344
Prevention of venous thrombosis and pulmonary embolism
Kakkar, V. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90116-i · Cited by 310
Levine, M. N., Hirsh, J., Gent, M., Turpie, A. G., Leclerc, J., Powers, P. J., Jay, R. M., & Neemeh, J. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-7-545 · Cited by 308
JCS Joint Working Group (2011) · Circulation Journal · doi:10.1253/circj.cj-88-0010 · Cited by 306
A Meta-analysis of Methods to Prevent Venous Thromboembolism Following Total Hip Replacement
Imperiale, T. F. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510460072036 · Cited by 245
Guide to anticoagulant therapy. Part 1: Heparin. American Heart Association.
Hirsh, J., & Fuster, V (1994) · Circulation · doi:10.1161/01.cir.89.3.1449 · Cited by 222
Colwell, C. W., Spiro, T. E., Trowbridge, A. A., Morris, B. A., Kwaan, H. C., Blaha, J. D., Comerota, A. J., & Skoutakis, V. A. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199401000-00002 · Cited by 217
Searching for Alternatives to Heparin Sulfated Fucans from Marine Invertebrates
Mourão, P. (1999) · Trends in Cardiovascular Medicine · doi:10.1016/s1050-1738(00)00032-3 · Cited by 174
Francis, C. W. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03480210073035 · Cited by 169
Poller, L., McKernan, A., Thomson, J. M., Elstein, M., Hirsch, P. J., & Jones, J. B. (1987) · BMJ · doi:10.1136/bmj.295.6609.1309 · Cited by 168
Metadata
- Authors
- Leyvraz, P. F., Richard, J., Bachmann, F., van Melle, G., Treyvaud, J.-M., Livio, J.-J., & Candardjis, G.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1983-10-20
- Volume
- 309
- Issue
- 16
- Pages
- 954-958
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2333865711
- Cited by
- 281
- References
- 3
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.