The DOI matches its Crossref record.
Tubal Infertility and the Intrauterine Device
Abstract
To study the association between intrauterine devices (IUDs) and pelvic inflammatory disease, we compared contraceptive histories in 4185 while women--283 nulliparous women with primary tubal infertility, 69 women with secondary tubal infertility, and 3833 women admitted for delivery at seven collaborating hospitals from 1981 to 1983. The relative risk of tubal infertility associated with IUD use was calculated by means of multivariate logistic regression to control for confounding factors, including region, year of menarche, religion, education, smoking, and reported number of sexual partners. The adjusted risk of primary tubal infertility associated with any IUD use before a first live birth was 2.0 (95 per cent confidence limits, 1.5 to 2.6) relative to nonuse. Users of the Dalkon Shield had an adjusted risk of 3.3 (1.7 to 6.1), users of the Lippes Loop or Saf-T-Coil had a risk of 2.9 (1.7 to 5.2), and users of copper IUDs had a risk of 1.6 (1.1 to 2.4). Women who reported having only one sexual partner had no increased risk of primary tubal infertility associated with IUD use. The adjusted risk of secondary tubal infertility associated with use of a copper IUD after a first live birth was not statistically significant (1.5; 95 per cent confidence limits, 0.8 to 3.0), whereas the risk from similar use of noncopper devices was significant (2.8; 1.3 to 5.9). We conclude that tubal infertility is associated with IUD use, but less so with copper IUDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
U.S. Medical Eligibility Criteria for Contraceptive Use, 2016
Curtis, K. M., Tepper, N. K., Jatlaoui, T. C., Berry-Bibee, E., Horton, L. G., Zapata, L. B., Simmons, K. B., Pagano, H. P., Jamieson, D. J., & Whiteman, M. K. (2016) · MMWR. Recommendations and Reports · doi:10.15585/mmwr.rr6503a1 · Cited by 1,456
Menken, J., Trussell, J., & Larsen, U. (1986) · Science · doi:10.1126/science.3755843 · Cited by 695
Smoking and female infertility: a systematic review and meta-analysis
Augood, C., Duckitt, K., & Templeton, A. A. (1998) · Human Reproduction · doi:10.1093/humrep/13.6.1532 · Cited by 510
Intrauterine device and upper-genital-tract infection
Grimes, D. A. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02699-4 · Cited by 333
Wallach, E. E., Stillman, R. J., Rosenberg, M. J., & Sachs, B. P. (1986) · Fertility and Sterility · doi:10.1016/s0015-0282(16)49628-7 · Cited by 304
Self-citation
Metadata
- Authors
- Cramer, D. W., Schiff, I., Schoenbaum, S. C., Gibson, M., Belisle, S., Albrecht, B., Stillman, R. J., Berger, M. J., Wilson, E., Stadel, B. V., & Seibel, M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1985-04-11
- Volume
- 312
- Issue
- 15
- Pages
- 941-947
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2095140184
- Cited by
- 186
- References
- 0
- FWCI
- 35.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tubal Infertility and the Intrauterine Device. https://app.cochat.ai/papers/10.1056/nejm198504113121502
- The paper
- Cramer, D. W., Schiff, I., Schoenbaum, S. C., Gibson, M., Belisle, S., Albrecht, B., Stillman, R. J., Berger, M. J., Wilson, E., Stadel, B. V., & Seibel, M. (1985). Tubal Infertility and the Intrauterine Device. New England Journal of Medicine. https://doi.org/10.1056/nejm198504113121502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.