Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Occlusion and restenosis are the most common reasons that transluminal balloon angioplasty may fail to provide long-term benefit. An intravascular mechanical support was therefore developed with the aim of preventing restenosis and sudden closure of diseased arteries after angioplasty. The endoprosthesis consists of a self-expandable stainless-steel mesh that can be implanted nonsurgically in the coronary or peripheral arteries. Experiments in animals showed complete intimal coverage within weeks and no late thrombosis during a follow-up period of up to one year. We performed 10 implantations in 6 patients for iliac or femoral arterial disease; 24 coronary-artery stents were implanted in 19 patients who presented with coronary-artery restenoses (n = 17) or abrupt closure (n = 4) after transluminal angioplasty or deterioration of coronary-bypass grafts (n = 3). We observed three complications in the group with coronary disease. One thrombotic occlusion of a stent resulted in asymptomatic closure, a second acute thrombosis was managed successfully with thrombolysis, and one patient died after bypass surgery for a suspected but unfound occlusion. Follow-up in the patients has continued for nine months without evidence of any further restenoses within the stented segments. Our preliminary experience suggests that this vascular endoprosthesis may offer a useful way to prevent occlusion and restenosis after transluminal angioplasty. Long-term follow-up will be required to validate the early success of this procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Restenosis after successful coronary angioplasty in patients with single-vessel disease.
Leimgruber, P. P., Roubin, G. S., Hollman, J., Cotsonis, G. A., Meier, B., Douglas, J. S., King, S. B., & Gruentzig, A. R. (1986) · Circulation · doi:10.1161/01.cir.73.4.710 · Cited by 695
Transluminal expandable nitinol coil stent grafting: preliminary report.
Dotter, C. T., BUSCHMAN, R. W., McKinney, M., & Rösch, J. (1983) · Radiology · doi:10.1148/radiology.147.1.6828741 · Cited by 332
Nonsurgical placement of arterial endoprostheses: a new technique using nitinol wire.
Cragg, A., Lund, G., Rysavy, J., Castaneda, F., Castaneda-Zuniga, W., & Amplatz, K. (1983) · Radiology · doi:10.1148/radiology.147.1.6828742 · Cited by 211
Cited by
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationMoses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Metadata
- Authors
- Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1987-03-19
- Volume
- 316
- Issue
- 12
- Pages
- 701-706
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2057330499
- Cited by
- 1,892
- References
- 3
- FWCI
- 67.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.