Use of Ambulatory Electrocardiographic Monitoring to Identify High-Risk Patients with Congenital Complete Heart Block
The DOI matches its Crossref record.
Abstract
To define the long-term natural history of congenital complete heart block, we followed 27 patients prospectively by means of frequent ambulatory electrocardiographic (ECG) recordings for a mean (+/- SD) of 8 +/- 3 years. During that time, 8 of the 13 patients with a mean daytime heart rate below 50 bpm (Group A) had cardiac complications such as sudden death, syncope, presyncope, or excessive fatigue. Six of the eight patients had additional ECG findings that suggested an instability of the junctional escape mechanism. These findings included nocturnal junctional exit block (three patients), little or no change in the junctional rate with physical activity (three patients), and associated tachyarrhythmias (three patients). None of the 14 patients with a mean daytime heart rate of 50 bpm or more (Group B) had an adverse clinical outcome, and 5 of the 13 patients in Group A also remained well. Among the five patients in stable condition in Group A, three had no evidence of an unstable junctional mechanism. We conclude that patients with a mean daytime junctional rate below 50 bpm and other evidence of an unstable junctional escape mechanism should probably undergo prophylactic pacemaker implantation. Since junctional exit block and tachyarrhythmias sometimes appear first during follow-up, the method of risk stratification employed in this study depends on serial ambulatory ECG recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Metadata
- Authors
- Dewey, R. C., Capeless, M. A., & Levy, A. M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1987-04-02
- Volume
- 316
- Issue
- 14
- Pages
- 835-839
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2340567332
- Cited by
- 130
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Ambulatory Electrocardiographic Monitoring to Identify High-Risk Patients with Congenital Complete Heart Block. https://app.cochat.ai/papers/10.1056/nejm198704023161403
- The paper
- Dewey, R. C., Capeless, M. A., & Levy, A. M. (1987). Use of Ambulatory Electrocardiographic Monitoring to Identify High-Risk Patients with Congenital Complete Heart Block. New England Journal of Medicine. https://doi.org/10.1056/nejm198704023161403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.