Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 533

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Difference between Endothelium-Dependent Relaxation in Arterial and in Venous Coronary Bypass Grafts

Lüscher, Thomas F., Diederich, Dennis, Siebenmann, Robert, Lehmann, Kurt, Stulz, Peter, Segesser, Ludwig von, Yang, Zhihong, Turina, Marko, Grädel, Erich, Weber, Erika, Bühler, Fritz R.·1988·New England Journal of Medicine

Abstract

Both the internal mammary artery and the saphenous vein are used to construct coronary-artery bypass grafts. We hypothesized that the release or production of endothelium-derived relaxing factor, which regulates blood flow and inhibits platelet function, may differ in venous and arterial grafts. We therefore studied endothelium-dependent relaxation in internal mammary arteries, internal mammary veins, and saphenous veins obtained from 58 patients undergoing coronary bypass surgery. Vascular rings with and without endothelium were suspended in organ chambers, and isometric tension was recorded. Acetylcholine (10(-8) to 10(-4) M), thrombin (1 U per milliliter), and adenosine diphosphate (10(-7) to 10(-4) M) evoked potent endothelium-dependent relaxation in the mammary artery but weak response in the saphenous vein (P less than 0.005; n = 6 to 27). In the mammary artery, relaxation was greatest in response to acetylcholine (86 +/- 4 percent reduction in norepinephrine-induced tension), followed by thrombin (44 +/- 7 percent) and adenosine diphosphate (39 +/- 8 percent). In the saphenous and mammary veins, relaxation was less than 25 percent. Relaxation was unaffected by indomethacin but was inhibited by methylene blue and hemoglobin (P less than 0.005 and 0.01, respectively), which suggests that endothelium-derived relaxing factor was the mediator. Endothelium-independent relaxation in response to sodium nitroprusside was similar in arteries and veins. We conclude that endothelium-dependent relaxation is greater in the mammary artery than in the saphenous vein. The possibility that this contributes to the higher patency rate among arterial grafts than among venous grafts will require further study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm198808253190802

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 533

Metadata

Authors
Lüscher, T. F., Diederich, D., Siebenmann, R., Lehmann, K., Stulz, P., Segesser, L. V., Yang, Z., Turina, M., Grädel, E., Weber, E., & Bühler, F. R.
Venue
New England Journal of Medicine
Published
1988-08-25
Volume
319
Issue
8
Pages
462-467
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2337043297
Cited by
533
References
26
FWCI
13.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Difference between Endothelium-Dependent Relaxation in Arterial and in Venous Coronary Bypass Grafts. https://app.cochat.ai/papers/10.1056/nejm198808253190802
The paper
Lüscher, T. F., Diederich, D., Siebenmann, R., Lehmann, K., Stulz, P., Segesser, L. V., Yang, Z., Turina, M., Grädel, E., Weber, E., & Bühler, F. R. (1988). Difference between Endothelium-Dependent Relaxation in Arterial and in Venous Coronary Bypass Grafts. New England Journal of Medicine. https://doi.org/10.1056/nejm198808253190802

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.