Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 477

The DOI matches its Crossref record.

Use of the Automatic External Defibrillator in the Management of Out-of-Hospital Cardiac Arrest

Weaver, W. Douglas, Hill, Deborah, Fahrenbruch, Carol E., Copass, Michael K., Martin, Jenny S., Cobb, Leonard A., Hallstrom, Alfred P.·1988·New England Journal of Medicine

Abstract

The automatic external defibrillator is a simple device that can be used by nonprofessional rescuers to treat cardiac arrest. In 1287 consecutive patients with out-of-hospital cardiac arrest, we assessed the results of initial treatment with this device by firefighters who arrived first at the scene, as compared with the results of standard defibrillation administered by paramedics who arrived slightly after the firefighters. Of 276 patients who were initially treated by firefighters using the automatic defibrillator, 84 (30 percent) survived to hospital discharge (expected rate according to a logistic model, 17 percent; P less than 0.001), as compared with 44 (19 percent) of 228 patients when fire-fighters delivered only basic cardiopulmonary resuscitation and the first defibrillation was performed after the arrival of the paramedic team. Few patients with conditions other than ventricular fibrillation survived. In a multivariate analysis of characteristics that influenced survival after ventricular fibrillation, a better survival rate was related to a witnessed collapse (odds ratio, 3.9; 95 percent confidence interval, 2.0 to 7.6), younger age (odds ratio, 1.2; 95 percent confidence interval, 1.0 to 1.4), the presence of "coarse" (higher-amplitude) fibrillation (odds ratio, 4.2; 95 percent confidence interval, 1.6 to 11.0), a shorter response time for paramedics (odds ratio, 1.4; 95 percent confidence interval, 1.0 to 2.1), and initial treatment by firefighters using an automatic external defibrillator (odds ratio, 1.8; 95 percent confidence interval, 1.1 to 2.9). These findings support the widespread use of the automatic external defibrillator as an important part of the treatment of out-of-hospital cardiac arrest, although the overall impact of the use of this device on community survival rates is still uncertain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm198809153191101

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 477

Metadata

Authors
Weaver, W. D., Hill, D., Fahrenbruch, C. E., Copass, M. K., Martin, J. S., Cobb, L. A., & Hallstrom, A. P.
Venue
New England Journal of Medicine
Published
1988-09-15
Volume
319
Issue
11
Pages
661-666
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W1967955745
Cited by
477
References
0
FWCI
25.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of the Automatic External Defibrillator in the Management of Out-of-Hospital Cardiac Arrest. https://app.cochat.ai/papers/10.1056/nejm198809153191101
The paper
Weaver, W. D., Hill, D., Fahrenbruch, C. E., Copass, M. K., Martin, J. S., Cobb, L. A., & Hallstrom, A. P. (1988). Use of the Automatic External Defibrillator in the Management of Out-of-Hospital Cardiac Arrest. New England Journal of Medicine. https://doi.org/10.1056/nejm198809153191101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.