Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 632

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Use of Automated External Defibrillators by a U.S. Airline

Page, Richard L., Joglar, José A., Kowal, Robert C., Zagrodzky, Jason D., Nelson, Lauren L., Ramaswamy, Karthik, Barbera, Saverio J., Hamdan, Mohamed H., McKenas, David K.·2000·New England Journal of Medicine

Abstract

BACKGROUND: Passengers who have ventricular fibrillation aboard commercial aircraft rarely survive, owing to the delay in obtaining emergency care and defibrillation. METHODS: In 1997, a major U.S. airline began equipping its aircraft with automated external defibrillators. Flight attendants were trained in the use of the defibrillator and applied the device when passengers had a lack of consciousness, pulse, or respiration. The automated external defibrillator was also used as a monitor for other medical emergencies, generally at the direction of a passenger who was a physician. The electrocardiogram that was obtained during each use of the device was analyzed by two arrhythmia specialists for appropriateness of use. We analyzed data on all 200 instances in which the defibrillators were used between June 1, 1997, and July 15, 1999. RESULTS: Automated external defibrillators were used for 200 patients (191 on the aircraft and 9 in the terminal), including 99 with documented loss of consciousness. Electrocardiographic data were available for 185 patients. The administration of shock was advised in all 14 patients who had electrocardiographically documented ventricular fibrillation, and no shock was advised in the remaining patients (sensitivity and specificity of the defibrillator in identifying ventricular fibrillation, 100 percent). The first shock successfully defibrillated the heart in 13 patients (defibrillation was withheld in 1 case at the family's request). The rate of survival to discharge from the hospital after shock with the automated external defibrillator was 40 percent. A total of 36 patients either died or were resuscitated after cardiac arrest. No complications arose from use of the automated external defibrillator as a monitor in conscious passengers. CONCLUSIONS: The use of the automated external defibrillator aboard commercial aircraft is effective, with an excellent rate of survival to discharge from the hospital after conversion of ventricular fibrillation. There are not likely to be complications when the device is used as a monitor in the absence of ventricular fibrillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm200010263431702

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 632

Metadata

Authors
Page, R. L., Joglar, J. A., Kowal, R. C., Zagrodzky, J. D., Nelson, L. L., Ramaswamy, K., Barbera, S. J., Hamdan, M. H., & McKenas, D. K.
Venue
New England Journal of Medicine
Published
2000-10-26
Volume
343
Issue
17
Pages
1210-1216
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2024208674
Cited by
632
References
13
FWCI
56.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Automated External Defibrillators by a U.S. Airline. https://app.cochat.ai/papers/10.1056/nejm200010263431702
The paper
Page, R. L., Joglar, J. A., Kowal, R. C., Zagrodzky, J. D., Nelson, L. L., Ramaswamy, K., Barbera, S. J., Hamdan, M. H., & McKenas, D. K. (2000). Use of Automated External Defibrillators by a U.S. Airline. New England Journal of Medicine. https://doi.org/10.1056/nejm200010263431702

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.