The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
The Safety and Efficacy of Chorionic Villus Sampling for Early Prenatal Diagnosis of Cytogenetic Abnormalities
Abstract
Chorionic villus sampling is a method of prenatal diagnosis in the first trimester of pregnancy in which tissue for genetic study is aspirated from the developing placenta by means of a catheter inserted transcervically under the guidance of ultrasonography. In this seven-center study, we compared the safety and efficacy of chorionic villus sampling in 2278 women with those of amniocentesis at 16 weeks' gestation in 671 women. Both groups were made up primarily of well-educated private patients; they were recruited in the first trimester of pregnancy and had viable pregnancies verified by ultrasound examination. Cytogenetic diagnoses resulted from 97.8 percent of the chorionic villus sampling procedures and 99.4 percent of the amniocenteses (P less than 0.05); aneuploidy was found in 1.8 and 1.4 percent, respectively, of the cases in which diagnoses were made. Of the women who underwent chorionic villus sampling, 17 (0.8 percent) subsequently had an amniocentesis because the diagnosis was ambiguous. Two of the diagnoses of aneuploidy (one tetraploidy, one trisomy 22) were later proved to be incorrect. On the basis of pediatric examination of the infants subsequently born to the women in the sample, there were no errors in the determination of sex or the identification of the major trisomies (21, 18, and 13). The rate of combined losses due to spontaneous and missed abortions, termination of abnormal pregnancies, stillbirths, and neonatal deaths was 7.2 percent in the group that underwent chorionic villus sampling and 5.7 percent in the group that had amniocentesis. After adjustment for slight differences in gestational and maternal age, the total loss rate for the women in the chorionic villus sampling group exceeded that for the amniocentesis group by only 0.8 percentage points (80 percent confidence interval, -0.6 to 2.2). The rate of loss of chromosomally normal fetuses after chorionic villus sampling was 10.8 percent among women in whom three or four attempts were made to place the transcervical catheter, as compared with 2.9 percent in those in whom only one attempt was necessary (P less than 0.01). There were no serious maternal infections among the women in this study or among an additional 1990 women who underwent chorionic villus sampling (upper 95 percent confidence limit, 0.08 percent). We conclude that chorionic villus sampling is a safe and effective technique for the early prenatal diagnosis of cytogenetic abnormalities, but that it probably entails a slightly higher risk of procedure failure and of fetal loss than does amniocentesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions.
D., F. N., & Fleiss, J. L. (1973) · Biometrics · doi:10.2307/2529186 · Cited by 1,388
Simoni, G., Brambati, B., Danesino, C., Rossella, F., Terzoli, G. L., Ferrari, M., & Fraccaro, M. (1983) · Human Genetics · doi:10.1007/bf00274761 · Cited by 484
LIVER DISEASE IN HBsAg CARRIERS
Fernández-de-Sevilla, T., Martínez-Vázquez, J. M., Ocaña, I., Ruibal, A., & Bacardí, R. (1982) · The Lancet · doi:10.1016/s0140-6736(82)90243-4 · Cited by 201
REVERSIBILITY OF AIRFLOW OBSTRUCTION
Postma, D. S., & SLUITER, H. J. (1988) · The Lancet · doi:10.1016/s0140-6736(88)91377-3 · Cited by 145
SPONTANEOUS FETAL LOSS RATE IN EARLY PREGNANCY
Gilmore, D. H., & McNay, M. B. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91997-x · Cited by 104
Spontaneous abortion and pregnancy outcome after normal first-trimester ultrasound examination.
Wilson, R. D., Kendrick, V., Wittmann, B. K., et al. (1986) · PubMed · Cited by 100
Missed abortion, and later spontaneous abortion, in pregnancies clinically normal at 7–12 wk
McFadyen, I. (1985) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(85)90061-9 · Cited by 17
3 Chromosome analysis on chorionic villi
Mikkelsen, M. (1987) · Baillière s Clinical Obstetrics and Gynaecology · doi:10.1016/s0950-3552(87)80005-6 · Cited by 6
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Update on Procedure-Related Risks for Prenatal Diagnosis Techniques
Tabor, A., & Alfirevic, Z. (2010) · Fetal Diagnosis and Therapy · doi:10.1159/000271995 · Cited by 399
Severe limb abnormalities after chorion villus sampling at 56-66 days' gestation
Firth, H. V., Boyd, P. A., Lindenbaum, R. H., Huson, S. M., Chamberlain, P., & Mackenzie, I. Z. (1991) · The Lancet · doi:10.1016/0140-6736(91)91374-4 · Cited by 380
SOGC Clinical Practice Guidelines
Lalonde, A. B. (1995) · Journal SOGC · doi:10.1016/s1701-2163(16)30568-0 · Cited by 306
Raff, H., Sharma, S. T., & Nieman, L. K. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130035 · Cited by 141
Metadata
- Authors
- Rhoads, G. G., Jackson, L. G., Schlesselman, S. E., de la Cruz, F. F., Desnick, R. J., Golbus, M. S., Ledbetter, D. H., Lubs, H. A., Mahoney, M. J., Pergament, E., Simpson, J. L., Carpenter, R. J., Elias, S., Ginsberg, N. A., Goldberg, J. D., Hobbins, J. C., Lynch, L., Shiono, P. H., Wapner, R. J., & Zachary, J. M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1989-03-09
- Volume
- 320
- Issue
- 10
- Pages
- 609-617
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2126663233
- Cited by
- 473
- References
- 8
- FWCI
- 51.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Safety and Efficacy of Chorionic Villus Sampling for Early Prenatal Diagnosis of Cytogenetic Abnormalities. https://app.cochat.ai/papers/10.1056/nejm198903093201001
- The paper
- Rhoads, G. G., Jackson, L. G., Schlesselman, S. E., de la Cruz, F. F., Desnick, R. J., Golbus, M. S., Ledbetter, D. H., Lubs, H. A., Mahoney, M. J., Pergament, E., Simpson, J. L., Carpenter, R. J., Elias, S., Ginsberg, N. A., Goldberg, J. D., Hobbins, J. C., Lynch, L., Shiono, P. H., Wapner, R. J., & Zachary, J. M. (1989). The Safety and Efficacy of Chorionic Villus Sampling for Early Prenatal Diagnosis of Cytogenetic Abnormalities. New England Journal of Medicine. https://doi.org/10.1056/nejm198903093201001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.