Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 953

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Prognostic Value of Serum Troponin T in Unstable Angina

Hamm, Christian W., Ravkilde, Jan, Gerhardt, Willie, Jørgensen, Poul, Peheim, Edgar, Ljungdahl, Lars, Goldmann, Britta, Katus, Hugo A.·1992·New England Journal of Medicine

Abstract

BACKGROUND: Cardiac troponin T is a regulatory contractile protein not normally found in blood. Its detection in the circulation has been shown to be a sensitive and specific marker for myocardial cell damage. We used a newly developed enzyme immunoassay for troponin T to determine whether its presence in the serum of patients with unstable angina was a prognostic indicator. METHODS: We screened 109 patients with unstable angina (25 with accelerated or subacute angina and 84 with acute angina at rest) for serum creatine kinase activity, creatine kinase isoenzyme MB activity, and troponin T every eight hours for two days after admission to the hospital. The outcomes of interest during the hospitalization were death and myocardial infarction. RESULTS: Troponin T was detected (range, 0.20 to 3.64 micrograms per liter; mean, 0.78; median, 0.50) in the serum of 33 of the 84 patients (39 percent) with acute angina at rest. Only three of these patients had elevated creatine kinase MB activity (two were positive for troponin T, and one was negative). Of the 33 patients who were positive for troponin T, 10 (30 percent) had myocardial infarction (3 after coronary-artery bypass surgery), and 5 of these died during hospitalization. In contrast, only 1 of the 51 patients with angina at rest who were negative for troponin T had an acute myocardial infarction (P less than 0.001), and this patient died (P = 0.03). Thus, 10 of the 11 patients with myocardial infarctions had detectable levels of troponin T; only 1 had elevated creatine kinase MB activity. Troponin T was not detected in any of the 25 patients with accelerated or subacute angina, and none of these patients died. CONCLUSIONS: Cardiac troponin T in serum appears to be a more sensitive indicator of myocardial-cell injury than serum creatine kinase MB activity, and its detection in the circulation may be a useful prognostic indicator in patients with unstable angina.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199207163270302

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 953

Metadata

Authors
Hamm, C. W., Ravkilde, J., Gerhardt, W., Jørgensen, P., Peheim, E., Ljungdahl, L., Goldmann, B., & Katus, H. A.
Venue
New England Journal of Medicine
Published
1992-07-16
Volume
327
Issue
3
Pages
146-150
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2340237670
Cited by
953
References
2
FWCI
28.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.