Out-of-Hospital Transcutaneous Pacing by Emergency Medical Technicians in Patients with Asystolic Cardiac Arrest
The DOI matches its Crossref record.
Abstract
BACKGROUND: Transcutaneous cardiac pacemakers generate electrical stimuli that pace the heart through external electrodes that adhere to the chest wall. Transcutaneous pacing has been useful in some patients with bradycardia, but its efficacy in patients with asystole and full cardiac arrest has been limited, possibly because of delays in the initiation of pacing. We studied the efficacy of early transcutaneous pacing in patients with out-of-hospital asystolic cardiac arrest. METHODS: For three years we provided transcutaneous pacemakers to about half the fire districts in a large emergency-medical-services system (the intervention group). In these districts, we authorized emergency medical technicians (EMTs) to begin transcutaneous pacing in patients with cardiac arrest and primary asystole or post-defibrillation asystole. Pacing was done as early as possible, before endotracheal intubation or intravenous medication. EMTs in the other fire districts (the control group) treated similar patients with basic cardiopulmonary resuscitation but without transcutaneous pacing. RESULTS: The EMTs in the intervention group initiated transcutaneous pacing in 112 of the 278 patients with primary asystole. Of these patients, 22 (8 percent) were admitted to the hospital, and 11 (4 percent) were discharged. Among the 259 patients treated by the EMTs in the control group, 21 (8 percent) were admitted to the hospital, and 5 (2 percent) were discharged. The two groups did not differ significantly with respect to the rate of hospital admission or survival. Survival after early pacing for post-defibrillation asystole was no better than survival after pacing for primary asystole. CONCLUSIONS: Transcutaneous pacing appears to offer no benefit in patients with asystolic cardiac arrest, even when it is performed as early as possible by EMTs in the field. Our data suggest that the widespread implementation of early transcutaneous pacing for out-of-hospital asystolic cardiac arrest would be ineffective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 59
- 10.1161/01.CIR.71.5.937 · DOI · Paper page
- 10.1016/S0196-0644(88)80074-X · DOI
- 10.1056/NEJM198311103091907 · doi:10.1056/nejm198311103091907
- 10.1097/00003246-198310000-00004 · doi:10.1097/00003246-198310000-00004
- 10.1111/j.1540-8159.1986.tb05365.x · doi:10.1111/j.1540-8159.1986.tb05365.x
- 10.1097/00003246-198505000-00006 · DOI
- 10.1016/S0196-0644(05)82138-9 · doi:10.1016/s0196-0644(05)82138-9
- Cummins R, 1989, Prehospital Disaster Med, 4, 70
- Cummins R, 1989, Prehospital Disaster Med, 4, 196
- 10.1016/S0196-0644(88)80618-8 · doi:10.1016/s0196-0644(88)80618-8
- 10.1111/j.1540-8159.1989.tb02666.x · doi:10.1111/j.1540-8159.1989.tb02666.x
- 10.1111/j.1540-8159.1990.tb06938.x · doi:10.1111/j.1540-8159.1990.tb06938.x
- 10.1111/j.1540-8159.1990.tb06936.x · doi:10.1111/j.1540-8159.1990.tb06936.x
- 10.1016/S0002-9343(88)80027-5 · doi:10.1016/s0002-9343(88)80027-5
- 10.1016/0002-9149(88)90767-9 · doi:10.1016/0002-9149(88)90767-9
- 10.1016/0002-8703(88)90242-6 · doi:10.1016/0002-8703(88)90242-6
- 10.1016/S0140-6736(82)91692-0 · doi:10.1016/s0140-6736(82)91692-0
- 10.1016/0736-4679(85)90390-7 · DOI
- 10.1016/S0196-0644(87)80678-9 · doi:10.1016/s0196-0644(87)80678-9
- 10.1161/01.CIR.76.6.1337 · doi:10.1161/01.cir.76.6.1337
- 10.1016/0735-6757(85)90035-X · doi:10.1016/0735-6757(85)90035-x
- 10.1016/S0196-0644(85)80090-1 · doi:10.1016/s0196-0644(85)80090-1
- 10.1016/S0196-0644(85)80096-2 · doi:10.1016/s0196-0644(85)80096-2
- 10.1016/S0196-0644(86)80004-X · doi:10.1016/s0196-0644(86)80004-x
- Tachakra SS, 1988, Arch Emerg Med, 5, 184, 10.1136/emj.5.3.184 · doi:10.1136/emj.5.3.184
- 10.1111/j.1540-8159.1988.tb05982.x · doi:10.1111/j.1540-8159.1988.tb05982.x
- 10.1016/S0196-0644(88)80282-8 · doi:10.1016/s0196-0644(88)80282-8
- 10.1016/S0140-6736(80)91305-7 · DOI
- 10.1001/jama.243.10.1049 · doi:10.1001/jama.243.10.1049
- 10.1056/NEJM198006193022502 · DOI · Paper page
- Eisenberg MS, 1986, Circulation, 74, IV
- Eisenberg MS, 1979, Am J Public Health, 69, 30, 10.2105/AJPH.69.1.30 · doi:10.2105/ajph.69.1.30
- 10.1001/jama.257.12.1605 · doi:10.1001/jama.257.12.1605
- 10.1016/0735-1097(88)91537-9 · doi:10.1016/0735-1097(88)91537-9
- 10.1056/NEJM198401263100403 · DOI
- 10.1161/01.CIR.69.5.943 · DOI
- 10.1016/S0196-0644(89)80200-8 · doi:10.1016/s0196-0644(89)80200-8
- 10.1016/S0196-0644(05)82282-6 · doi:10.1016/s0196-0644(05)82282-6
- 10.1016/S0196-0644(89)80259-8 · DOI
- 10.1016/S0196-0644(87)80613-3 · doi:10.1016/s0196-0644(87)80613-3
- 10.1016/0002-8703(89)90670-4 · DOI · Paper page
- Cummins RO, 1991, Circulation, 83, 1832, 10.1161/01.CIR.83.5.1832 · DOI · Paper page
- 10.1016/0002-9149(90)91285-E · DOI
- 10.1016/S0196-0644(86)80862-9 · doi:10.1016/s0196-0644(86)80862-9
- 10.1038/scientificamerican0586-37 · doi:10.1038/scientificamerican0586-37
- Cobb LA, 1980, Mod Concepts Cardiovasc Dis, 49, 31
- 10.1016/S0196-0644(86)80430-9 · doi:10.1016/s0196-0644(86)80430-9
- 10.1016/0300-9572(90)90005-Y · doi:10.1016/0300-9572(90)90005-y
- 10.1016/0300-9572(90)90103-L · doi:10.1016/0300-9572(90)90103-l
- 10.1016/S0196-0644(05)80927-8 · doi:10.1016/s0196-0644(05)80927-8
- 10.1016/S0196-0644(86)80003-8 · doi:10.1016/s0196-0644(86)80003-8
- 10.1056/NEJM195211132472005 · DOI · Paper page
- Zoll PM, 1954, Circulation, 9, 482, 10.1161/01.CIR.9.4.482 · doi:10.1161/01.cir.9.4.482
- 10.1016/0002-9343(57)90384-4 · doi:10.1016/0002-9343(57)90384-4
- 10.1016/S0196-0644(84)80450-3 · doi:10.1016/s0196-0644(84)80450-3
- Aronson AL, 1986, Med Instrum, 20, 27
- 10.1016/0735-6757(88)90228-8 · doi:10.1016/0735-6757(88)90228-8
- 10.1097/00003246-198511000-00018 · doi:10.1097/00003246-198511000-00018
- Syverud S, 1988, Emerg Med Clin North Am, 6, 197, 10.1016/S0733-8627(20)30556-3 · doi:10.1016/s0733-8627(20)30556-3
Cited by
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
European Resuscitation Council Guidelines for Resuscitation 2015
Soar, J., Nolan, J. P., Böttiger, B. W., Perkins, G. D., Lott, C., Carli, P., Pellis, T., Sandroni, C., Skrifvars, M. B., Smith, G. B., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.016 · Cited by 1,503
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
Metadata
- Authors
- Cummins, R. O., Graves, J. R., Larsen, M. P., Hallstrom, A. P., Hearne, T. R., Ciliberti, J., Nicola, R. M., & Horan, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1993-05-13
- Volume
- 328
- Issue
- 19
- Pages
- 1377-1382
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2000270673
- Cited by
- 128
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Out-of-Hospital Transcutaneous Pacing by Emergency Medical Technicians in Patients with Asystolic Cardiac Arrest. https://app.cochat.ai/papers/10.1056/nejm199305133281903
- The paper
- Cummins, R. O., Graves, J. R., Larsen, M. P., Hallstrom, A. P., Hearne, T. R., Ciliberti, J., Nicola, R. M., & Horan, S. (1993). Out-of-Hospital Transcutaneous Pacing by Emergency Medical Technicians in Patients with Asystolic Cardiac Arrest. New England Journal of Medicine. https://doi.org/10.1056/nejm199305133281903
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.